2024-07-05

  • Display artifacting reduced by cable length, but not eliminated.

  • Planer testing drift between 14-15 cm no issue.

  • Intermittent exit code 74 uploading to R4 from Windows laptop.

    • Double reset button is one fix.
  • 6690 steps is 1 cm. 3 cm minimum, 15 cm maximum.

  • down 1: no error

  • up 1: no error

  • down 2: ~0.5 mm error

  • up 2: no error

  • down 3: ~0.5 mm error

  • up 3: no error

  • down 4: ~0.5 mm error

  • up 4: no error

  • down 5: ~0.5 mm error

  • up 5: no error

  • down 6: ~0.5 mm error

  • up 6: no error

  • down @ 80952: perfect -- 6746 steps is new 1 cm.

  • 111 F motor while running, 80 F power supply, 84 F driver, 80 F arduino Uno R4