Repository navigation
Getting started
English · Italiano
This page uses the CAN tab of the ribbon; LIN and J1939 work the same way in their own tabs. You can try everything without hardware using the Simulation driver.
CAN → Hardware Configuration → Driver Selection, then choose your interface (or Simulation). In Channel Configuration set the baud rate of each channel: pick it from the list (10 kbit/s to 1 Mbit/s) or type another value. BUSMASTER-NG remembers the last baud rate you used with each interface, also when you do not save the configuration, and offers it the next time.
With a database BUSMASTER-NG shows message names and signal values instead of raw bytes.
- DBC file (Vector CANdb++): CAN → Database → Load DBC (or Ctrl+Shift+M)
- BUSMASTER database (.dbf): CAN → Database → Database → Associate (or Ctrl+M)
Details in Databases and DBC.
CAN → Hardware Configuration → Connect. The button turns to Disconnect while the bus is active.
The Message Window (CAN → Measurement Windows → Message Window) lists the messages on the bus.
- Interpret shows the signals of each message (needs a database).
- Overwrite keeps one row per message id instead of a growing list.
- Time Mode switches between system, absolute and relative time.
- Frequency (Hz) (CAN) shows how often each message arrives, from the time between the last messages ("-" for the first one). In Overwrite mode a message that does not arrive for three times its period (at least 100 ms) turns grey and shows "-" until it comes again.
- Click a column header to sort the list (CAN: ID, Message, Channel, Time, Tx/Rx, Msg Type, DLC, Frequency); click again to reverse. In Overwrite mode the sorting stays while the bus is connected.
- View → Hex\Dec switches between hexadecimal and decimal.
Other windows in the same group: Signal Watch (chosen signals with their values), Signal Graph (plots) and Network Statistics (bus load, errors).
Open CAN → Simulation Windows → Transmit Window.
- In the message list, use the empty last row to add a message: type its id, or choose its name if a database is loaded.
- Below, set the data bytes or, better, the physical values of the signals (negative values are allowed when the signal can be negative).
- Send Message sends it once; with a repetition time and the check box ticked it is sent cyclically while connected. The repetition can be typed as time (Repetition (ms)) or as frequency (Frequency (Hz)): the other one is calculated. The shortest repetition time is 1 ms (1000 Hz) on Windows 10 (1803 or later) and Windows 11 and 2 ms (500 Hz) on Windows 7, which has no timer fine enough: a shorter value is raised to the minimum.
The window can be enlarged: the lists grow with it.
File → Save stores everything (driver, databases, windows, transmit list) in a .cfx configuration file.
File → Load opens it again. Configurations of BUSMASTER 3.2.x open in BUSMASTER-NG too.
CAN → Measurement Windows → Logging → Configure to choose the log file and its format, then Activate. Log files can be converted (ASC, BLF, Excel, ...) with Tools → Format Converter.
The built-in help (Help → View Help or F1) describes every window. Its pictures still show the original BUSMASTER, the functions are the same.
BUSMASTER-NG · community fork of BUSMASTER (ETAS / Bosch), LGPL v3 · not affiliated with ETAS GmbH or Robert Bosch GmbH · Something wrong or out of date on this page? / Qualcosa di sbagliato o non aggiornato? Open an issue