Skip to content

Releases: Sienna-Platform/PowerSystemsTestData

5.0-dev12

5.0-dev12 Pre-release
Pre-release

Choose a tag to compare

@jd-lara jd-lara released this 06 Oct 04:21

Test data for the psy6 line on SDK 0.2 (SiennaSchemas 0.2.0) and the Unitful per-unit API (PowerSystems.jl #1818).

Changes since 5.0-dev11:

  • Follow the fixed-quantity control fields (from #127).
  • Write per-unit values and input_basis as Unitful units: 0.6u"CU" and input_basis = u"CU".
  • Replace MonitoredLine and the HVDC active_power_limits_* fields with operational_flow_limit. Each old limit becomes the max in the same direction, and each min is 0.0.
  • Give the generic HVDC lines a rating in place of their symmetric active power limits.
  • Store the converter DC voltage setpoint in kV: 500.0 on the 500 kV DC bus of the 10-bus AC/DC case.

5.0-dev5

Choose a tag to compare

@jd-lara jd-lara released this 15 Aug 04:59
b65af26

Migrates the 5-bus fixtures to the psy6 reserve and cost APIs.

  • Reserves: ConstantReserve/VariableReserve -> OnlineReserve, VariableReserveNonSpinning -> OfflineReserve. The ORDC is no longer its own type; it is an OnlineReserve carrying its demand curve on variable.
  • Market-bid fixtures moved to the psy6 cost API.
  • TModelHVDCLine fixtures carry the now-required base_current.

Lets PowerSystemCaseBuilder drop the compatibility shims in psy6_compat.jl.

v4.0.6

Choose a tag to compare

@jd-lara jd-lara released this 29 Jul 17:43
8d3934c

Update PSSe case

5.0-dev2

5.0-dev2 Pre-release
Pre-release

Choose a tag to compare

@jd-lara jd-lara released this 24 Jul 01:25
7879e9d
transformer refactor changes (#121)

* transformer refactor changes

* remove base power from top level transformer

* name updates

* Migrate PSID serialized-system fixtures off the stateful units schema

Replace top-level units_settings (SystemUnitsSettings enum + base
value) with a flat base_power field, and rename the per-component
internal units_info key to base_value, matching the current PSY
serialization shape. Affects 9BusSystem.json, WECC_240_dynamic.json,
omib_sys.json, and threebus_sys.json.

* re-serialize latest

* typo

4.0.5

Choose a tag to compare

@jd-lara jd-lara released this 09 Jul 21:22

Add facts_shunt.raw PSS/E case for FACTS shunt parser tests (used by PowerSystemCaseBuilder pti_facts_shunt_sys).

v5.0-dev

v5.0-dev Pre-release
Pre-release

Choose a tag to compare

@acostarelli acostarelli released this 12 Jun 20:25
Use LinearFunctionData for HydroReservoir head_to_volume_factor

head_to_volume_factor is FunctionData after PSY #1710, not a ValueCurve.

v4.0.4

Choose a tag to compare

@jd-lara jd-lara released this 07 Jul 19:21
24fb17b

Release with additional tap control cases

v4.0.3

Choose a tag to compare

@jd-lara jd-lara released this 27 May 05:22
e005304

Adding ICD cases

v.4.0.2

Choose a tag to compare

@jd-lara jd-lara released this 16 Dec 15:04
094708d

Add new dataset for hydro outages

v4.0.1

Choose a tag to compare

@jd-lara jd-lara released this 02 Nov 21:43

Full Changelog: 4.0.0...4.0.1