0.2.2b2 - Aggregator beta hotfix 1
Translations and the sensor file were not included in the last commit and release for an unknown reason; this fixes that and should now render config/options flow modals correctly. Sensor inputs and outputs were truncated/missing from desync.
Full Changelog: 0.2.2b1...0.2.2b2
Aggregator Beta
This beta release adds:
-
Several new optional input sensors for users with their own weather data.
-
ASHRAE PMV entity with 2 new number inputs to represent metabolic rate (sitting/standing, working out) and what type of clothing this area was designed for (bedroom vs living room or home gym)
-
Australian Apparent Temperature (AAT) is used
-
Configure the total area in m2 of a room to calculate heat loss in watts and fine tune an aggregators weighted temperature
-
Configure the floor that each room is on for stratification data and the stack effect between floors (aggregator required)
-
New aggregator class to group virtual rooms into an HVAC zone, house floor or a whole house
- this allows you to create an aggregator named 'basement' where each room has been configured to be on floor
-1, main floor is 0, 2nd is 1, etc. - Nesting aggregators is supported, if you create a basement and main floor aggregator, you can then create a whole house aggregator with the basement and main floor aggregators (WIP, temperature spread is wonky when using nested aggregators)
- the temperature spread for a single floor/HVAC zone is automatically calculated and exposed in the aggregator temperature entity attributes
- the aggregator only exposes one entity: a weighted temperature
- weight is based on each room's area in m2, the larger a room, the more weight in the calculation
- this allows you to create an aggregator named 'basement' where each room has been configured to be on floor
-
Several logic changes
-
Migration of config flow to v4 (it should auto-migrate)
- You now need to choose between creating a virtual room or an aggregator
- Several new optional input sensors in config/options flow
Please test and open issues.
Full Changelog: v0.2.1...0.2.2b1
Psychrometric data, dedicated sensors, dynamic convection and closed loop Kloss calibration
- several optional dedicated input sensors have been added for users with weather stations/outdoor sensors.
- config flow has been updated to include sections
- dynamic convection calcs based on climate, window, door, fan entities and heating system type
- added optional "surface wall temp" sensor to expose a calculated k-loss sensor (no more guessing!).
- fixed mold risk sensor: forgotten 2.5 multiplier to simulate a thermal bridge.
What's Changed
- sun azimuth, convective weighting, radiant system or forced air bool, cover/shading factor. by @baudneo in #4
- Allow an optional relative humidity sensor for psychrometric data and mold risk by @baudneo in #5
- Auto modeling - calibrated K_loss by @baudneo in #6
Full Changelog: v0.1.0...v0.2.1