Skip to content

Database columns

Manuel edited this page Aug 29, 2026 · 1 revision

Database columns

A reading only survives the archive interval if the table has a column for it. Without one it appears in reports as a current value and is gone at the next archive interval.

WeeWX's standard schema has 113 columns. A well equipped Ecowitt or Ambient station can fill four times that.

What the standard schema covers

Series Channels
extraTemp, extraHumid 1..8
batteryStatus, signal 1..8
soilTemp, soilMoist 1..4
leafTemp, leafWet 1..2

Everything else has to be added: soilTemp5 and above, soilMoist5 and above, leafWet3 and above, and approximately twenty-five families that do not exist there at all, among them air_ch, depth_ch, soilEC, pm25_ and leak_.

Add only what arrives

python -m user.ultimatepush --port 8001 --config /etc/weewx/weewx.conf

One upload, and the command prints the statements for exactly the columns your station needs:

20 readings have nowhere to live. They will show up in reports as current
conditions and be gone at the next archive interval. To keep them:

  weectl database add-column soilTemp2 --type REAL --config=/etc/weewx/weewx.conf -y
  weectl database add-column lightning_num --type INTEGER --config=/etc/weewx/weewx.conf -y
  weectl database add-column vpd --type REAL --config=/etc/weewx/weewx.conf -y
  ...

Adding a column changes the table definition and not its rows.

Twenty columns for a station with a lightning sensor, two soil probes and a WH52, rather than four hundred.

Before running them

The web interface has a button in each row that runs the same ALTER TABLE. Everything below is the same operation from a terminal.

Back up the database first. Adding a column is not dangerous in itself: on SQLite it changes the table definition and leaves the rows alone, measured at 7.6 ms on a table of 300,000 records, with the file the same size afterwards. Removing a column again means rebuilding the table around it, and a mistyped name is easier to type than to undo.

sudo systemctl stop weewx
cp /var/lib/weewx/weewx.sdb /var/lib/weewx/weewx.sdb.backup

Then run the commands and start WeeWX again.

Column types

INTEGER for counted values, REAL for measured ones. The tool selects by unit group: group_count, group_time, group_boolean and group_data become INTEGER, and everything else REAL.

Columns that already hold data

This matters before changing anything about a running station, and the driver checks it in two places.

When a station is set up in the web interface, the archive table is read and the columns that station would write are checked against it. Anything that already holds readings is reported, with the number of rows and the date of the most recent one, and the station is not set up until you confirm. Where the choice can be avoided it is: a channel whose extraTempN and extraHumidN already hold readings is skipped when a channel is assigned automatically. See Stations.

The diagnostic command reports the same information:

12 of these fields already hold readings:

  soilTemp1                     104832 values, last 2026-08-25
  outTemp                       104832 values, last 2026-08-25

If those came from the same sensor, there is nothing to do. If they came
from a different one, this driver is about to write a second series into
the same column, and afterwards the two cannot be told apart.

The check is one pass over the archive table, so it is made when the interface is first opened rather than on every page load.

Moving a series to another column

sudo systemctl stop weewx
weectl database rename-column soilTemp1 extraTemp9 -y
sudo systemctl start weewx

Then adjust field_map_extensions to match. Renaming keeps the history; mapping the field elsewhere without renaming starts a second series.

Starting with a larger schema

For a new installation, a schema that has the extra columns from the outset is easier than adding them later. See the WeeWX customization guide, The database, for how to point [DataBindings] at a schema of your own.