Skip to content

Releases: marculab/FLImBrushDataProcessingTool

v0.3.1 with bug fix

Choose a tag to compare

@xnzhou1991 xnzhou1991 released this 13 Mar 03:44
  • check CFD shift result, if the shift standard deviation is larger than 10, something is wrong, skip CFD alignment of waveforms
  • fixed GUI channel 4 result plotting bug

v0.3.0 release

Choose a tag to compare

@xnzhou1991 xnzhou1991 released this 16 Nov 00:33
  • using the last 50 points from each waveform for DC removal
  • the voltage to cap gain for irf is now a function of runDeconLG function
  • disable multi exponential decon low signal modal popup, display warning in command window instead
  • updated how irf index for gain cap is computered: interpolate irf V first, the directly find max irf index.
  • extended operation phasor and spectral phasor added to DeconLit file

Full Changelog: v0.2.0...v0.3.0

v0.2.0

Choose a tag to compare

@xnzhou1991 xnzhou1991 released this 31 Oct 00:43
  • using 'pchip' for gain interpolation
  • updated expDeconObj to be a dynamic field that is generated in run time
  • added code to reprocess brain data with exponential decon

Full Changelog: v0.1.0-alpha...v0.2.0

v0.1.0-alpha

v0.1.0-alpha Pre-release
Pre-release

Choose a tag to compare

@xnzhou1991 xnzhou1991 released this 03 Oct 04:36

What's Changed

  • updated iRF shift function to use recursive search
  • updated GUI to work with both 3 and 4-channel data
  • updated code to cap iRF at gain of 10
  • updated UCD MC clinical system APD detector file to APD file after 4-channel upgrade
  • reset software version to 0.1.0
  • save the software version in channelData object file and Decon Lite file
  • fully compatible with data processed with older version of the software

Full Changelog: https://github.com/marculab/FLImBrushDataProcessingTool/commits/v0.1.0-alpha