Attribute Table

Functional domains

Domain Byte Name
Setup 0x01 Installer, scale, time, reset
Control 0x02 Modes, setpoints, IAQ controls
Scheduling 0x03 Program, hold, away, heat blast
Alerts 0x04 Reminders, alerts, alert settings
Sensors 0x05 Temps, humidity, modules, written ODT
Lockout 0x06 Local UI lockouts
Status 0x07 COS, sync, equipment status, errors
Identification 0x08 Model, MAC, name
Messaging 0x09 Message center
Display 0x0A LCD backlight

Attributes (domain · attribute)

Setup 0x01

Attr Name COS Access
1 Thermostat Installer Settings Yes R
2 Contractor Information Yes R/W
3 Scale No R/W
4 Date and Time No R/W
5 Air Cleaning Installer Settings Yes R
6 Humidity Control Installer Settings Yes R
7 Fresh Air Installer Settings Yes R
8 Reset / Power cycle No W

Control 0x02

Attr Name COS Access
1 Thermostat Setpoint & Mode Settings Yes R/W
2 Increment Setpoint No W
3 Dehumidification Setpoint Yes R/W
4 Humidification Setpoint Yes R/W
5 Fresh Air Setting Yes R/W
6 Air Cleaning Setting Yes R/W
7 Thermostat & IAQ Available Yes R

Scheduling 0x03

Attr Name COS Access
1 Schedule Settings Yes R/W
2 Away Settings Yes R/W
3 Schedule Day Yes R/W
4 Schedule Hold Yes R/W
5 Heat Blast Yes R/W

Alerts 0x04

Attr Name COS Access
1 Service Reminders Status Yes R/W
2 Alerts Status Yes R
3 Alerts Settings Yes* R/W

* The guide notes COS for Alerts Settings is supported on the 8840 only, sent when settings are saved to EEPROM.

Sensors 0x05

Attr Name COS Access
1 Sensor Values No R
2 Controlling Sensor Values Yes R
3 Support Modules Yes R
4 Written Outdoor Temperature Value Yes R/W

Lockout 0x06

Attr Name COS Access
1 Lockout Settings Yes R/W

Status 0x07

Attr Name COS Access
1 COS Subscriptions No R/W
2 Sync No W
5 Offline Yes NA
6 Thermostat Status Yes R
7 IAQ Status Yes R
8 Thermostat Error Yes R

(3–4 reserved)

Identification 0x08

Attr Name COS Access
1 Revision & Model Yes R
2 MAC Address No R
5 Thermostat Name No R/W

Guide section number is 8.5; attribute byte is 0x05.

Messaging 0x09

Attr Name COS Access
1 Permanent Messages No R/W
2 Temporary Message No R/W

Display 0x0A

Attr Name COS Access
1 LCD Backlight Settings * R/W

* The guide's attribute table lists COS: No, but section 10.1 lists "COS caused by: backlight settings change at the thermostat", and COS Subscriptions has a Backlight Settings byte (19) — see Guide Errata.