Domain: Status (0x07)

7.1 COS Subscriptions

COS No
Access R/W
Length 29 bytes (indices 0–28)

Each byte: 0 Not subscribed, 1 Subscribed.

Byte Subscribes to
0 Installer Thermostat Settings
1 Contractor Information
2 Air Cleaning Installer Settings
3 Humidity Control Installer Settings
4 Fresh Air Installer Settings
5 Thermostat Setpoint & Mode
6 Dehumidification Setpoint
7 Humidification Setpoint
8 Fresh Air Setting
9 Air Cleaning Settings
10 Thermostat IAQ Available
11 Schedule Settings
12 Away Settings
13 Schedule Day
14 Schedule Hold
15 Heat Blast
16 Service Reminders Status
17 Alerts Status
18 Alerts Settings
19 Backlight Settings
20 Thermostat Location & Name
21 Reserved
22 Controlling Sensor Values
23 Over-the-air ODT update timeout
24 Thermostat Status
25 IAQ Status
26 Model & Revision
27 Support Module
28 Lockouts

Defaults (guide bold): every byte defaults to 1 Subscribed, except byte 1 (Contractor Information), which defaults to Subscribed on the 8920W/8840 only, and byte 21 (Reserved). Disable unused COS to reduce traffic.

7.2 Sync

COS Complete signaled as COS
Access W
Data length 2 bytes
Byte Field
0 1 = start sync / (COS) sync complete
1 Reserved

Host write 1 → thermostat emits all subscribed COS + error status + final Sync complete COS with 1.

7.5 Offline

COS Yes
Access NA (thermostat-originated)
Byte Field
0 0 Normal, 1 Offline

Used during firmware update on HA-configured units.

7.6 Thermostat Status

COS Yes
Access R
Byte Field
0 Heating equipment status 0–14 (idle, wait, stages, comps, aux, elec combos)
1 Cooling equipment status 0–6
2 Progressive recovery 0/1
3 Fan 0 Not active, 1 Active

Heating values: 0 Not Active, 1 Equipment Wait, 2 Stage1, 3 Stage1+2, 4 Stage1+2+3, 5 Comp1, 6 Comp1+2, 7 Aux1, 8 Aux2, 9 Comp1+Elec1, 10 Comp1+Elec2, 11 Comp1+2+Elec1, 12 Comp1+2+Elec2, 13 Elec1, 14 Elec2.

Cooling: 0 Idle, 1 Wait, 2–4 stages, 5–6 compressor combos.

7.7 IAQ Status

COS Yes
Access R
Byte Field Values (summary)
0 Dehumidification 0 Idle, 1 Wait, 2 Whole home On, 3 Overcool to dehum, 4 Off
1 Humidification 0 Idle, 1 Wait, 2 Active, 3 Off
2 Ventilation 0 Idle, 1 Wait, 2 Active, 3 High temp lockout, 4 Low temp lockout, 5 High RH lockout, 6 Off
3 Air cleaning 0 Idle, 1 Wait, 2 Active, 3 Off

7.8 Thermostat Errors

COS Yes
Access R
Byte Field
0 Error code
Code Meaning
0 No error
1 E1 Built-in temp sensor open
2 E2 Built-in temp sensor short
3 E3 NVRAM access error (except 8840)
4 E4 Reserved
5 E5 ECM communication lost (except 8810/8820)
6 E6 Remote temp open (except 8810)
7 E7 Remote temp short (except 8810)
8 E8 Support module temp lost