Domain: Lockout (0x06)

COS Yes
Access R/W
Data length 8 bytes

Locks local thermostat controls so the homeowner cannot change mode/fan/setpoints (or only within limits).

Byte Field Values
0 Lockout type 0 None (default), 1 Full, 2 Partial
1 Mode lockout 0 Disabled, 1 Enabled (ignore if type Full/None)
2 Fan lockout 0 / 1
3 Dehumidifier lockout 0 / 1
4 Menu screen lockout 0 Disabled, 1 Enabled
5 Setpoint lockout 0 Off; 1 Range; 2 Timed+Range; 3 Full
6 Setpoint range Index → ±1–20 °F (0.5–10 °C steps) — see guide table
7 Setpoint time Index → 15–480 minutes in 15 min steps — for timed lockout

Full: enables mode/fan/dehum lockouts and full setpoint lockout. None: clears those. Partial: per-field configuration.

Increment Setpoint over protocol is not restricted by lockouts.

Guide typo: Byte 4 (Menu Screen Lockout) lists "0: Disabled 1: Enabled 3-255: Reserved", leaving value 2 unaccounted; presumed intent is 2–255 reserved. See Guide Errata.