Repository navigation
Editing samples
Select a sample in the SAMPLE view's list to edit it. Everything here works without a sampler connected.

Above the waveform are the sample's name (type to rename it), its rate, number of samples and length, and badges:
-
SAMPLER RATE, 7.9KHZ BANDWIDTH: the rate is one of the sampler's.NOT A SAMPLER RATEmeans it will be resampled when sent. -
FITS: THE SAMPLER ENDS IT AT THE LOOP END: the sample is longer than the sampler can hold, but its loop ends in time, so it plays the same. -
TOO LONGorLOOP END PAST THE SAMPLER'S 0.83S: the sampler can't hold it as it is. See Fitting in the sampler. -
FROM THE SAMPLER: received from the sampler, or loaded from a disk image. See Received samples.

- The markers S and E are START and END, LS and LE the loop start and loop end. Drag them to move the points. A marker you grab also selects its parameter, so the DATA knob or the arrow keys then move it one sample at a time.
- Zoom with the mouse wheel, around the pointer, down to single samples. Double click to zoom in. −, + and ALL zoom out, in and to the whole sample, and START, LOOP START, LOOP END and END zoom to a point.
- Move the view by dragging, or with Shift and the mouse wheel. The strip under the waveform shows the whole sample and where the view is; click it to move there.
- What isn't used is dimmed: before START and after END.
- The red dashed SAMPLER LIMIT line shows where the sampler's 32752 samples end, counted from START.
- An attack and a crossfade loop are drawn on it: above, the curves at START are the attack, and the shaded parts before the loop start and before the loop end are the two sides of the crossfade.
- While a note plays the sample, a line shows where each voice is playing.
| Parameter | |
|---|---|
| START | Where playing starts. |
| END | Where a one shot stops. The loop ends at END at the latest: moving END before the loop end pulls the loop end with it. |
| SCAN | As on the sampler: ONE shot plays until the key is let go, LOOP repeats the loop, ALT plays the loop back and forth, DRUM (drum trigger) plays to the end whatever the key does. |
| DIR | FWD, or REV to play from END back to START, as the sampler's SCAN DIRECTION. A loop then plays mirrored. |
| LOOP START, LOOP END | The loop. |
The detail on the display shows each point in seconds. As on the sampler, START can be inside the loop, after the loop start: the sample then plays from START to the loop end once, and loops back to a loop start before it.
PLAY (hold it) plays the sample at its own pitch.
The sampler holds at most 32752 samples per slot: 0.83 s at its highest rate, 39.6 kHz, and twice as long at each octave lower. A looped sample fits if its loop ends within the limit, as the sampler stops at the loop end.

Here the loop ends at 1.65 s, past the 0.83 s the sampler holds at 39.6 kHz. There are two ways to make it fit:
- move the loop and END earlier, or START later
- resample it to a lower rate: at 19.8 kHz the sampler holds 1.66 s. That is what was done to it in the picture at the top of the page. A lower rate sounds duller, as on the sampler.
The edits below are settings. A sample keeps its original, as it was loaded, and is made again from it with the edits whenever one of them or a point changes. So you can normalize after moving START, or go back to the original rate, and nothing is lost. What plays, what the waveform shows, and what is sent or saved is the edited sample.
RESAMPLE TO sets the rate: OWN for the original's rate, or one of the sampler's 41 rates, a semitone apart,
from 39.6 kHz down to 3.9 kHz. The display shows the longest sample the sampler holds at that rate (MAX 1.66S). The
points stay at the same times, and the keygroups play the sample at the same pitch.
The sampler has no attack setting, so ATTACK renders one into the sample: what plays first fades in from silence.
- LENGTH: in ms, OFF for none.
- SHAPE: LIN rises evenly, CURVE starts slower, like an exponential attack.
The attack starts at START (at END when reversed) and has to end before the loop starts.
CROSSFADE smooths the jump at the end of a forward loop, so it doesn't click: the last part of the loop fades into what comes just before the loop start.
- LENGTH: in ms, OFF for none. It can't be longer than the room there is before the loop start.
- SHAPE: LIN for a steady sound, alike on both sides of the loop. EQP (equal power) keeps the level when the two sides differ, as with noise.
In the AS SENT box on the left:
- NORMALIZE: the part between START and END brought to full level. Loaded files start with it on.
- 12 BIT: the sample reduced to the 12 bit values the sampler keeps, to hear it as the sampler will play it.
The line under them shows the peak level, and what happens when the sample is sent (MADE 12 BIT WHEN SENT).
RESET EDITS takes away all the edits above: the sample is its original again, at the original rate.
APPLY EDITS writes the edits into the sample: the sample as it sounds becomes its new original, and only START to END of it is kept (from the loop start, if that is before START). Use it to keep a part of a long recording, for example:

Here 1.5 s of a 7 s recording is used, USING 1.50S OF 7.00S, resampled to 19.8 kHz. After APPLY EDITS, the sample is
those 1.5 s at 19.8 kHz, with no edits left to undo:

It asks first. The original as loaded is let go: RESET EDITS then goes back to this new version. A memory file saved before still has the original. The button is greyed out when there is nothing to write or cut.
A sample received from the sampler, or loaded from a disk image, is marked FROM THE SAMPLER. It is sent back exactly as it came, so its audio isn't edited: there are no attack, crossfade, resample or normalize settings for it. Its points, scan mode, direction and sound can still be changed.
- SAVE WAV saves the sample as it sounds, as a WAV file with its loop, which other programs read. Axs7 also writes its START, END, scan mode, direction, sound, slot and key ranges into it, which other programs skip. Loading the file again brings all of it back.
-
SAVE QD saves the sample as a disk image for the sampler (
.qd) for a Gotek or HxC floppy emulator, with its settings and key ranges. It is saved at the nearest sampler rate and 12 bit. On the sampler the root note and fine tune belong to the sample, so the first keygroup's are saved, and the other keygroups' roots go in their transpose. The MIDI log says what had to change. Saved images are tested by loading them in Axs7, not yet on a sampler. - DELETE takes the sample out of memory and out of every program and bank (it asks first).
To save everything at once, see Banks and memory.