Notifications
You must be signed in to change notification settings - Fork 3
Device Types

The plugin provides five device types. Each is independent — you can create only the ones you need.
The primary device. Represents one physical Envoy gateway on your network.
| Field | Required | Description |
|---|---|---|
| IP Address | ✅ | LAN IP of the Envoy (e.g. 192.168.1.50) |
| Use Manual Token | For FW≥7 | Tick to enter a pre-generated JWT token |
| Serial Number | When manual token | Serial number for the Envoy |
| Authentication Token | When manual token | The JWT from entrez.enphaseenergy.com |
| Generate Token | For FW≥7 | Auto-fetch token using Enlighten credentials |
| Enphase Login | When generate token | Your Enlighten email |
| Enphase Password | When generate token | Your Enlighten password |
| Enable Panel Data? | Optional | Enables per-inverter panel devices |
| Unmetered Envoy >7 Firmware | Rare | Force production-only mode if Envoy-S is unmetered |
The device's summary display state is powerStatus — shown in the Indigo device list and control pages.
| Value | Meaning |
|---|---|
offline |
Cannot contact Envoy |
producing |
Solar generating but no metering info |
exporting |
Net power > +100 W (feeding grid) |
importing |
Net power < −100 W (drawing from grid) |
neutral |
Net power within ±100 W (batteries or near-balance) |
idle |
No production detected |
Create one EnphaseEnvoyDevice per physical Envoy gateway. If you have two Envoy systems, create two devices.
For older Envoy-C hardware (pre-Envoy-S) that only reports production — no consumption metering.
| Field | Required | Description |
|---|---|---|
| IP Address | ✅ | LAN IP of the Envoy |
| Envoy Serial Number | Optional | Enables per-panel data access (if supported) |
-
wattsNow— current production (W) -
wattHoursToday,wattHoursSevenDays,wattHoursLifetime -
powerStatus— producing / idle / offline
No consumption, no per-phase data, no panel devices.
One device per microinverter. Auto-created by clicking Generate Panel Indigo Devices in the parent Envoy-S device settings. Never create manually.
- The plugin fetches the inverter list from the Envoy.
- One
EnphasePanelDeviceis created for each unique serial number. - Devices are placed in the same Indigo folder as the parent Envoy device.
- If a device with the same serial number already exists, it is skipped (safe to re-generate).
- Panel devices are named
Enphase Panel 1,Enphase Panel 2, etc. (or the next available number if names already exist).
watts — current AC power output for this panel (W).
| Source | Requires | Data Richness | Freshness |
|---|---|---|---|
/ivp/peb/devstatus |
Installer token | Medium (watts, voltage, temp) | ⭐⭐⭐ Best |
/ivp/pdm/device_data |
Any token | Full (watts, AC/DC V/I, energy) | ⭐⭐ Good |
/api/v1/production/inverters |
Legacy/any | Basic (watts only) | ⭐ Fallback |
The plugin uses devstatus for real-time watts (fastest), and device_data for the extended fields (temperature, DC voltage, energy) cached every 15 minutes.
A panel is marked offline (watts→0, communicating→False) if:
- The Envoy reports it as
gone; or - Its last report timestamp is more than 25 minutes old.
The last known lastCommunication timestamp is preserved even when a panel goes offline, so you can see when it last spoke.
Aggregates data from all Encharge batteries and presents a combined view with grid flow data.
No configuration required. The device automatically uses the first online EnphaseEnvoyDevice for all API calls.
batteryState — idle, charging, discharging, offline, or unknown.
- Combined battery state of charge (%), watts, capacity (Wh/kW)
- Per-battery temperature and maximum cell temperature
- Battery serial numbers and firmware versions
- Grid import/export watts and net flow
- Storage mode, charge-from-grid setting, reserve SOC
Updated automatically every time the parent Envoy device refreshes (every 60 seconds). Use the Refresh Battery & Grid Data action for an on-demand refresh.
Calculates energy costs based on configurable tariff rates.
| Field | Description |
|---|---|
| All day Consumption Tariff $/kWh | What you pay for grid electricity |
| All day Production Tariff $/kWh | What you receive for exported solar (feed-in tariff) |
Note: The plugin uses a flat (single) rate for both consumption and production. Time-of-use (TOU) tariffs with multiple rates are not yet supported.
netTarrifToday — today's net cost/credit in dollars.
All monetary values are formatted as $x,xxx.xx strings.
| State | Description |
|---|---|
productionTarrifToday |
Solar earnings today |
consumptionTarrifToday |
Grid electricity cost today |
netTarrifToday |
Net today (production earnings − consumption cost) |
productionkWToday |
kWh produced today |
consumptionkWToday |
kWh consumed today |
netkWToday |
Net kWh today |
productionTarrif7days / consumptionTarrif7days / netTarrif7days
|
7-day equivalents |
productionTarrifLifetime / consumptionTarrifLifetime / netconsumptionTarrifLifetime
|
Lifetime equivalents |
Recalculated automatically every time the parent Envoy device updates states — no separate polling.