Skip to content

Manual Controls

P0k3sm0t edited this page May 23, 2026 · 1 revision

Manual Controls

Manual Controls are on the Dashboard. They are for jogging, homing, air assist, pausing, resuming, stopping, unlocking, and low-power test fire.

Controls

Control Use
Step Jog distance in millimeters
Feedrate Jog speed/feedrate
X/Y arrow pad Jog in single-axis or diagonal moves
Center Move to configured bed center
Home Home all axes
Go To Preset Move to the configured preset X/Y position
Unlock / Clear Alarm Send unlock/clear alarm behavior
Air On / Air Off Toggle air assist/pump commands
Pause Feed hold/pause
Resume Cycle start/resume
Stop Job Stop/abort based on Job Control settings
Test Fire Timed low-power laser test, if enabled

How to use safely

  1. Check the Status card first.
  2. Confirm the laser is off.
  3. Use small jog steps near the edges.
  4. Keep your hand away from the machine while jogging.
  5. Do not use Test Fire unless eye/fire safety is ready.

Stop behavior

Stop behavior depends on Settings > Job Control. The normal safe behavior is:

  1. Send laser off.
  2. Abort/reset the job if soft reset stop is allowed.
  3. Refresh status.

If Stop is set to hold-only, it behaves more like Pause.

Troubleshooting

Problem Check
Jog does not move Ray5 may be offline, alarmed, or locked
Home fails Machine may need unlock or homing support may differ
Air buttons do nothing Confirm your Ray5 pump/air control responds to M8/M9
Pause/Resume response looks odd GRBL real-time commands may not return normal ok text
Stop is disabled or weak Check Job Control settings
Test Fire disabled Enable it in Settings > Safety