Notifications
You must be signed in to change notification settings - Fork 35
Communication&API
The operator interface reaches the backend over two channels, both served by the same HTTP server on port 3001: a REST API for commands and reads, and Socket.IO for live data. Commands go down through REST; state and live values come up through Socket.IO.
The REST API is per-machine:
| Method & path | Purpose |
|---|---|
GET /machine |
List the connected machines |
GET /machine/{slug}/{serial} |
Read one machine |
POST /machine/{slug}/{serial} |
Send a command to one machine |
{slug} is the machine's short name (derived from its identification) and {serial} is its serial number. A POST carries a JSON body, the server forwards it to the target machine as a message (HttpApiJsonRequest), and the machine applies it on its next cycle through its api_mutate handler, so commands never block the real-time loop. The server binds 0.0.0.0:3001.
Live data flows over Socket.IO, encoded with MessagePack for compactness. There are two kinds of namespace:
- A main namespace carries cross-cutting events: the list of connected machines, the EtherCAT devices, and network-interface discovery.
- A per-machine namespace carries that machine's state and live values, emitted as typed events. It is keyed by the machine identification —
/machine/{vendor}/{machine}/{serial}— the same key the frontend subscribes to.
Each event type declares a caching strategy (for example, keep the latest value). The namespace retains those cached events, so a client that subscribes late immediately receives the machine's current state instead of waiting for the next update.
To drive a machine, a client lists the machines (GET /machine, or the main namespace), subscribes to that machine's Socket.IO namespace to receive its live state, and POSTs commands to /machine/{slug}/{serial}. See Frontend for how the desktop application does exactly this.