Signal Generator

Val edited this page Nov 23, 2026 · 4 revisions

Six waveforms with digit-by-digit frequency entry. The generator keeps running in the background while you use the oscilloscope or the multimeter.

Keys

Key Action
F1 Wave Waveform panel: shape, duty, level or amplitude
F2 Frequency Frequency editor
F3 Params Parameters panel: duty, level, presets, layout
F4 Output / HOLD Output on/off
MODE Tap or hold for 1 s to return to the oscilloscope. In the scope, hold MODE to return to the generator

On the generator screen, ←/→ step the frequency on the grid 1, 2 … 9 × 10ⁿ (… 900 Hz, 1 kHz, 2 kHz … 9 kHz, 10 kHz …). A step right and a step left return to the same value. A frequency off the grid moves to its nearest grid neighbour, and the top limit of the waveform is the last step. ↑/↓ change duty, level or amplitude, as labelled.

Frequency editor: ←/→ select the digit, ↑/↓ change it, F2 again switches Hz / kHz / MHz, MENU applies, F4 cancels, F1/F3 apply and open the other panels.

Waveforms and limits

Waveform ZT703S max ZT706S max
Sine 344 kHz 10 MHz
Square 1 MHz (PWM) 2 MHz
Triangle 100 kHz 2 MHz
Half sine 129 kHz 2 MHz
Positive sine 294 kHz 2 MHz
Sawtooth (ramp) 100 kHz 200 kHz

Duty is set for square waves.

Level

  • ZT703S: level profiles Dedicated, Low, High or Custom DAC codes (0–4095). The preview line shows what sets the level, for example DAC 600-3600. Values are DAC output codes without voltage calibration. Square out: by default DAC below 1 kHz and PWM from 1 kHz, or PWM always. Preset Reference 1kHz: 1 kHz 50 % square.
  • ZT706S: amplitude in volts, 0.1 V steps; duty 1–100 % in 0.1 % steps.

Probe calibration output (ZT703S)

While the generator output is OFF, the oscilloscope screen drives the output jack with a 1 kHz, 50 % square wave for adjusting ×10 probes. The generator still shows OFF. Turning the output on takes the jack with your waveform, and turning it off brings the square back. The square stops on the multimeter screen, while the multimeter's serial output is on, during zero and gain calibration, during a run mode change and at power-off. After an output error it waits until you switch the output off. The voltage at the jack has not been measured yet.

At power-on

Settings → Device → Power → Generator at startup: Off (default, output off after power-on) or Restore last (the output turns on again if you last switched it on).

Layout

The order of the frequency, the preview and the soft-keys is set in Settings → Display → Generator layout or F3 → Layout. Changing it does not interrupt the output.

When the generator streams from the DAC, the oscilloscope's maximum sample rate is halved; the scope shows ADC max /2.