Skip to content

Menu Map

Val edited this page Nov 24, 2026 · 12 revisions

Every menu and panel of OpenOSC on one page. Each branch shows how you get there; values in [ ] are the choices of a row. How to move through panels is described in Controls.

  • → marks a sub-page.
  • (703) and (706) mark rows that exist on one model only.
  • Rows marked action run when you press MENU.

Settings (hold MENU for 1 s)

Settings
├── Display
│   ├── Brightness ........................ 10–100 %
│   ├── Top bar counter ................... [Off | FPS | Sample rate]
│   ├── Battery ........................... [Icon | Volts | Percent]
│   ├── Clock indicator ................... [Off | On]  L/M/H profile letter in the scope top bar
│   ├── Pan direction ..................... [Move view | Move waveform]
│   ├── Scope shortcuts →
│   │   ├── AUTO key ...................... [Quick | Classic]
│   │   ├── F2 hold ....................... [Home view | Reset zoom & pan]
│   │   └── F4 hold ....................... [Cursor settings | Measurements | Acquisition |
│   │                                        Record memory | Interleave CH1 (where available)]
│   ├── Generator layout .................. order of the generator screen's blocks
│   ├── Tooltips →
│   │   ├── Usage tips .................... [Off | On]
│   │   ├── Action unavailable ............ [Off | On]
│   │   ├── Progress ...................... [Off | On]
│   │   ├── Completions ................... [Off | On]
│   │   ├── Advisory warnings ............. [Off | On]
│   │   └── Critical alerts ............... always on
│   └── Appearance →
│       ├── Reload theme JSON ............. action
│       └── Use built-in theme ............ action
├── Files & USB
│   ├── Reload settings JSON .............. action
│   ├── Recovery / USB files .............. action: restart into Recovery
│   ├── USB controller .................... [Disabled | Enabled (200 MHz only)]
│   ├── USB Remote ........................ action
│   ├── Screenshots ....................... screenshot viewer
│   └── Clear screenshots ................. action (asks first)
└── Device
    ├── About ............................. version, model, libraries
    ├── Storage ........................... storage size, file system, free space
    ├── Performance →
    │   ├── Run mode ...................... [200/100 | 280/140 | 360/90]
    │   ├── Interleave CH1 ................ [Off | On: CH1 alone]  (703, experimental)
    │   │                                   [Off | On: CH1 alone | Auto: factory rules]  (706)
    │   ├── Record memory ................. total points of the enabled channels
    │   └── Restart device ................ action
    ├── Power →
    │   ├── Backlight timeout ............. [Off | 30 s | 60 s | 120 s]
    │   ├── Idle backlight ................ [Off | 5 | 10 | 15 | 20 | 25 %]
    │   ├── Auto power off ................ [Off | 15 | 30 | 60 min]
    │   ├── Power-off hold ................ [1 s | 1.5 s | 2 s]
    │   ├── Generator at startup .......... [Off | Restore last]
    │   ├── Battery gain .................. −10.0 to +10.0 %, in 0.1 % steps
    │   └── Battery offset ................ −250 to +250 mV, in 5 mV steps
    ├── Restore settings .................. action (asks first)
    └── Scope calibration →
        ├── Hardware zero (PWM) ........... action
        ├── Software zero ................. action
        ├── Gain →
        │   ├── Channel ................... [CH1 | CH2]
        │   ├── V/div ..................... 20 mV … 10 V
        │   ├── Reference at tip .......... number, 1 mV resolution
        │   ├── Reference step ............ [1 mV | 10 mV | 100 mV | 1 V | 10 V]
        │   ├── Probe ..................... shown: the channel's probe
        │   ├── Expected span ............. shown
        │   ├── Gain in force ............. shown
        │   ├── Start measurement ......... action
        │   ├── Factory gain .............. shown: CH1 / CH2
        │   ├── Match to other channel .... wizard: both channels on one square wave
        │   └── Use factory gain .......... action
        ├── Interleave offset (703) ....... action: measure with CH1 grounded
        ├── Interleave gain & timing (703)  wizard: sine tones on CH1, Save profile
        ├── Interleave offset → (706)
        │   ├── Offset .................... ±16 codes, 0.1 steps
        │   ├── In force / Saved .......... shown
        │   ├── Save ...................... action
        │   ├── Cancel .................... action
        │   └── Reset to factory .......... action
        ├── Reload calibration JSON ....... action
        └── Use factory zero .............. action

Details: Settings Menu, Performance Profiles, Calibration, USB and Remote Mode.

Oscilloscope

Channel panel (F1 or F2, then MENU)

Hold F1 to open the Probe picker directly.

Channel panel
├── Channel ............................... [CH1 | CH2]
├── Enabled ............................... [Off | On]
├── Coupling .............................. [DC | AC]
├── Probe ................................. [1:1 | 10:1 | 50:1 | 100:1 | 500:1 | 1000:1 | 10000:1]
├── Scale / div ........................... 20 mV … 10 V
├── Analog zero ........................... position, 0–160
├── Invert ................................ [Off | On]
├── Trace brightness ...................... [10–100%]
├── Density ............................... [Off | Colors | Mono]
└── Density color ......................... [Channel | color swatches]

Trigger panel (F3, then MENU)

The first F3 press selects Trigger. Further presses cycle Auto, Normal and Single. On the Trigger card, ↑/↓ adjust the level and ←/→ adjust pretrigger. Holding F3 sets pretrigger to 50% and sets the level to the signal midpoint if a completed capture is available.

Trigger panel
├── Source ................................ [CH1 | CH2]
├── Edge .................................. [Rising | Falling]
├── Level ................................. number
├── Mode .................................. [Auto | Normal | Single]
├── Pretrigger ............................ number, %
├── Center trigger ........................ action: mark to the centre, Pretrigger 50 %
├── Noise reject .......................... [Off | On]
└── Set level to 50% ...................... action

Zoom & Pan (hold AUTO in Quick mode)

In Y-T or Y-T+FFT with a captured record, ↑/↓ zoom the visible window and ←/→ pan. Zoom-out requires the full requested span to fit in the record. F4 returns to the previous control and keeps the adjusted view, with ZOOM or PAN shown on the plot. Hold F2 to reset the view.

Analyze (F4, or MENU from the Cursor card)

Analyze
├── Display →
│   └── Section ........................... [View | Capture rendering | Cursors | History | FFT |
│       │                                    Frequency counter]
│       ├── View
│       │   ├── View ...................... [Y-T | X-Y | FFT | Y-T+FFT]
│       │   ├── Channel ................... [CH1 | CH2]
│       │   ├── Zoom ...................... [1x | 2x | 4x … 256x]; Zoom & Pan can also show factors below 1x
│       │   ├── Horizontal position ....... −1000 to +1000 thousandths of the record (←/→ 1, ↑/↓ 25)
│       │   ├── Center trigger ............ action
│       │   ├── CHn visible ............... [Off | On]
│       │   ├── CHn invert ................ [Off | On]
│       │   ├── CHn digital gain .......... [1% | 25% | 50% | 75% | 100% … 6400%]
│       │   ├── CHn digital offset ........ number
│       │   ├── Grid ...................... [Full | Major | Axes | None]
│       │   ├── Grid brightness ........... [0–100%]
│       │   └── MATH ...................... [Off | CH1+CH2 | CH1-CH2]
│       ├── Capture rendering
│       │   ├── Samples ................... [Peak | HD mean | Auto (HD/Peak)]
│       │   ├── Interpolation ............. [Linear | Sinc | Spline]
│       │   ├── Trace ..................... [Vectors | Points | Envelope]
│       │   ├── Average ................... [1 | 4 | 16 | 64]
│       │   ├── Peak hold ................. [Off | On]
│       │   └── Glow ...................... [Off | On]
│       ├── Cursors
│       │   ├── Channel ................... [CH1 | CH2]
│       │   ├── Time cursors .............. [Off | On]   (Frequency cursors in FFT)
│       │   ├── Voltage cursors ........... [Off | On]   (Level cursors in FFT)
│       │   ├── Cursor A time, Cursor B time
│       │   └── Cursor a level, Cursor b level
│       ├── History
│       │   ├── Persistence ............... [0 | 250 | 500 | 1000 | 5000 | 10000 ms | Infinite]
│       │   ├── Capture CHn reference ..... action
│       │   └── Clear history and reference  action
│       ├── FFT
│       │   ├── FFT source ................ [CH1 | CH2]
│       │   ├── FFT window ................ [Rectangular | Hann | Hamming | Blackman]
│       │   ├── FFT scale ................. [Linear | dBFS]
│       │   └── FFT remove DC ............. [Off | On]
│       └── Frequency counter
│           ├── Counter ................... [Off | CH1 | CH2]
│           ├── Readings averaged ......... [1 | 3 | 10]
│           └── Clock correction .......... ±1000 ppm
├── Measurements →
│   ├── Measure over ...................... [Screen (visible window, fast) | Full record (every point)]
│   └── CH1 readout 1–4, CH2 readout 1–4 .. [Frequency | Peak to peak | RMS | Period | Mean |
│                                            Minimum | Maximum | AC RMS | Duty | Pulses (rising edges) |
│                                            Hardware frequency / FCNT | Amplitude (Top - Bottom) |
│                                            Top (robust high) | Bottom (robust low) | Off]
├── Cursors ............................... [Off | Time | Level | Time+Level]  (Frequency in FFT)
├── Layout → .............................. Position 1, 2 …: order of the waveform, the readouts and the soft keys
├── Colors →
│   ├── Scheme ............................ built-in schemes or custom
│   ├── Element ........................... the screen element to change
│   ├── Source / Red / Green / Blue ....... the element's color
│   ├── Reset element ..................... action
│   └── Reset all ......................... action
├── Acquisition →
│   ├── Time / div ........................ 10 ns … 20 s
│   ├── Record memory ..................... total points
│   ├── Captured .......................... shown
│   ├── Sample rate ....................... shown
│   └── Rolling ........................... [Auto | Off]
├── Decoder → ............................. see below
├── Rearm Single .......................... action
├── Save RAW .............................. action
├── Save CSV .............................. action
├── FFT spectrum .......................... action  (FFT settings in an FFT view)
├── Center channels ....................... action
├── Reset pan ............................. action
├── Trigger 50% ........................... action
└── Bode (FRA) → .......................... see [[Bode Analyzer]]

With the default shortcut, hold F4 to open the Cursors section directly. Press Back to return to the Cursor card with Time A selected, or Level a if only voltage cursors are on. Cursor controls

Decoder (Analyze → Decoder)

The rows after Update depend on the protocol.

Decoder
├── Protocol .............................. [Off | UART | I2C | SPI | LIN | CAN]
├── View .................................. [Wave + annotations | Split | Decoder only]
├── Update ................................ [Complete | Live (unavailable)]
├── UART: RX line, Baud, Detect baud, Data bits [5–9], Parity [None | Even | Odd | Mark | Space],
│         Stop bits [1 | 1.5 | 2], Bit order [LSB first | MSB first], Idle level [High | Low (inverted)]
├── I2C:  SDA / SCL
├── SPI:  SCLK / data, SPI mode [0–3, CPOL/CPHA], Word bits, Bit order, Word start [After a pause | Manual start],
│         Pause or Start point
├── LIN:  LIN line, Baud, Checksum [Classic | Enhanced], Length of ID, ID 0xNN bytes
├── CAN:  Source [RXD on CH1 | RXD on CH2 | CANH CH1 - CANL CH2], Bit rate, Sample point,
│         FD data rate, FD data SP
├── Threshold of each line ................ (CANH-CANL thr for a CAN difference)
├── Hysteresis ............................ [Auto | Manual (mV)], then Hysteresis mV
├── Min pulse ............................. number
└── Save CSV .............................. action (when a decoder is on)

Details: Oscilloscope, Protocol Decoders.

Multimeter (MENU)

Measurement panel
├── Range ................................. [Auto | Manual]  (None or Unknown where the function has no range)
├── Display ............................... [Primary | Statistics | Trend | Analog]
├── Base colors ........................... color palette
├── Base digits ........................... digit typeface
├── Appearance →
│   ├── Preset ............................ [Custom | Hybrid]
│   ├── Base colors
│   ├── Element ........................... the screen element to change
│   ├── Color / Red / Green / Blue
│   ├── Font, Style
│   ├── Reset element ..................... action
│   └── Reset all ......................... action
├── Layout → .............................. order of the screen's blocks
├── Statistics ............................ [Off | On]
├── Bar graph ............................. [Off | On]
├── Relative .............................. [Off | On]
├── Hold →
│   ├── Mode .............................. [Manual | Delayed | Stable | Auto]
│   ├── Delay ............................. Delayed: the countdown
│   ├── Stable time, Stable band .......... Stable and Auto: what counts as stable
│   ├── Rearm threshold ................... Auto: change needed before the next hold
│   └── Min readings ...................... Stable and Auto
├── Reset statistics ...................... action
├── CSV logging ........................... [Off | On]
├── Junction source ....................... Type K: [Manual | MCU at startup | MCU live]
├── Manual junction ....................... Type K: −50.0 … 100.0 °C, 25.0 by default
├── Temp units ............................ Type K: [°C | °F]
└── Serial 115200 ......................... [Off | On]  (GEN on while the generator uses the jack)

Details: Multimeter.

Signal generator

F1 opens WAVEFORM, F3 opens PARAMETERS, F2 the frequency editor.

WAVEFORM (F1)
├── Wave .................................. [Sine | Square | Triangle | Half sine | Positive sine | Sawtooth]
├── Duty .................................. square waves
├── Level (703) / Amplitude (706)
└── Frequency

PARAMETERS (F3)
├── Duty
├── Level (703) / Amplitude (706)
├── Square out (703) ...................... [Factory: DAC <1kHz | PWM always]
├── DAC min, DAC max (703)
├── Preset ................................ ready-made settings, Reference 1kHz (703)
├── Frequency
└── Layout ................................ order of the screen's blocks

Details: Signal Generator.

Recovery (hold F2 while the device starts)

OPENOSC RECOVERY
├── UPDATE FIRMWARE ....................... choose a file in /openosc/UPDATE/, CONFIRM
├── VIEW CALIBRATION ...................... built-in calibration data, read only
├── BACKUP FACTORY BOOT ................... copy of the boot block to /openosc/BACKUP/
├── CHECK / REPAIR FAT .................... report, then repair options
├── START APPLICATION ..................... CONFIRM
├── POWER OFF
└── FORMAT EXTERNAL DISK .................. CONFIRM; all files are lost

Details and screenshots: Recovery.

Clone this wiki locally