FAQ
Can I damage my device? OpenOSC never writes to the protected boot block that holds the boot code and the calibration, and Recovery checks every image before erasing anything. Still, this is experimental firmware and you install it at your own risk. An optional backup of the boot block is described in Installation.
Do I lose my calibration? No. The device's calibration data is only read. Your own oscilloscope corrections are separate files (Calibration).
Which model do I have, and does it matter? It matters: each model has its own files. See Supported Devices.
Will OpenOSC be available for other devices? OpenOSC currently targets the ZT703S and ZT706S. I own a FNIRSI 2C53T and an ALIENTEK DM40, and I'm considering hardware and software modifications for both devices for my own use. If there is interest from the community, I may start separate projects for these devices. If you'd like to help test, please get in touch in Discussions.
Why are there so many releases? Software development has changed a lot with AI tools: a fix or a new feature that used to take weeks can now be written and checked in hours. Automated tests catch a lot, but real devices, real signals and real users still find problems that no test finds. So OpenOSC is released as soon as a change has passed its checks. Each fix reaches your device quickly, and when something breaks, the cause is easy to find among the few changes since the previous version.
You do not need to install every release. Update when a release fixes something you use or adds something you want. The release notes say what changed and whether Recovery needs an update too.
Do updates keep my settings? Yes. Settings and calibration files are on the device storage, and updates keep them (Updating).
Why is USB not working at 280/140 or 360/90? USB data is only supported in the 200/100 profile (Performance Profiles).
Why does USB disconnect when I switch between oscilloscope and multimeter? The device changes its instrument profile and reconnects (USB and Remote Mode).
Why does the battery indicator show CHG?
CHG appears while the firmware detects active charging from the board's status lines. The firmware samples a voltage, but it has no battery current reading to track how much charge has been added. During the constant-voltage phase, the cell can reach 4.20 V while it is still taking charge. A percentage calculated from that voltage alone can reach 100 % early. Texas Instruments battery gauging overview
The Battery gain and Battery offset settings correct the displayed voltage and the estimate derived from it. A live voltage display during charging would require confirming that the voltage sampled by the firmware tracks the cell terminals while external power is connected. Battery display settings, feature request #110
Can I edit settings on a computer?
Yes, they are JSON files in /openosc/SETTINGS and /openosc/UI (Files on the Device).
Is there live protocol decoding? The decoder works on each captured record as a whole (Protocol Decoders).
Is the generator output calibrated? No. On ZT703S the level is set in DAC codes and profiles; on ZT706S the amplitude is nominal (Signal Generator).
Is there a language other than English? Not at the moment.
Where do I ask questions? In Discussions.
OpenOSC is licensed under the GPL-3.0. Found a mistake on this page? Tell us in Discussions.