The same keys work the same way on every screen. Each screen gives F1–F4 its own meaning; the labels above F1–F4 always show what each key does right now.

Keys

Key Short press Hold
MODE Next screen: Oscilloscope → Multimeter → Generator. Closes an open panel —
MENU Opens the panel of the current screen; in a panel or menu, takes the selected row 1 s: Settings
HOLD / SAVE Oscilloscope: Run/Stop. Multimeter: HOLD. Generator: output on/off 1 s: screenshot of the screen
AUTO / RANGE Oscilloscope: reset the pan. Multimeter: manual range / next range 2 s: oscilloscope Auto Setup, multimeter auto range
REL / Power Multimeter: relative measurement on/off From 0.5 s a "Hold to power off" bar; after the Power-off hold time (1, 1.5 or 2 s, default 2 s) the device switches off and saves the settings. Release earlier to cancel
F1–F4 Screen-specific, see each instrument page Oscilloscope F2: center channels; F3: trigger level to 50 %
Arrows Change the selected parameter; in panels, move between rows Repeat (after 0.4 s, every 80 ms)

A hold never also triggers the short-press action. Keys held while the device starts must be released first.

Panels and menus

The instrument panels (MENU on a screen) and Settings (hold MENU) work the same way. Each row is a list, a switch, a number, an action or a sub-page.

You are on Keys
The rows ↑/↓ select a row. MENU opens a list, flips a switch, starts editing a number, runs an action or opens a sub-page. → opens a sub-page. F4 or ← goes back (closes the panel at the top level)
An open list ↑/↓ choose (the current value is marked with <). MENU takes it. F4 or ← closes without a change
A number being edited ←/→ (and ↑/↓) step the value. MENU keeps it. F4 restores the value it had before you started

When a change takes effect:

  • Oscilloscope and generator panels: field by field. A list choice or a switch applies at once; a number applies when you press MENU. Stepping a number does not restart the capture or the generator.
  • Multimeter panel and Settings: every change applies at once.
  • Settings and the theme are written to the storage when you switch the device off, restart it or enter Recovery. A battery pull, a crash or a reset loses the changes made since then.
  • If the device refuses a change (for example, switching off the last enabled channel), the row shows the value actually in use and a message explains why.

MODE, entering USB Remote mode or powering off while a number is being edited works like F4: the unfinished edit is dropped.

Status bar

The top line shows the run state, trigger, the FPS or sample rate (Settings → Display → Top bar counter), record memory, USB and battery. On the oscilloscope the run state reads STOP in HOLD, TRIG'D while frames trigger and AUTO while Auto mode runs free; the multimeter shows LIVE, HOLD and REC while CSV logging runs.

When a menu continues on another page, More ↓ appears under the rows.