Repository navigation
Multimeter
DC/AC voltage, millivolts, Type K temperature, DC/AC current, milliamps, resistance, continuity, diode and capacitance, with auto and manual ranges, HOLD modes, REL, statistics, trend and logging.
| Key | Action |
|---|---|
| F1 | Voltage group (each press: next function of the group) |
| F2 | Resistance / continuity / diode / capacitance group |
| F3 | Current group |
| F4 | V/Ω jack: DC mV → AC mV → Type K. mA jack: DC mA → AC mA |
| AUTO / RANGE | Short press: manual range, then the next range. Hold 2 s: auto range |
| ↑ / ↓ | Change the manual range |
| ← / → | Primary / statistics / trend view |
| HOLD | Hold, according to the HOLD mode below |
| REL | Use the current reading as the reference; press again to clear |
| MENU | Panel: range, display, statistics, HOLD, relative, CSV logging, serial output, layout and colors |
Each key press sends exactly one command to the meter; the function shown is always the one the meter reports. In diode and continuity, AUTO/RANGE is ignored (no ranges).
Set in MENU → Measurement → Hold:
| Mode | HOLD press | Shows |
|---|---|---|
| Manual (default) | Freezes the reading; again: live | HOLD |
| Delayed | Counts down, then holds the next reading |
DELAY n, then HOLD
|
| Stable | Waits for a stable reading and holds it once |
WAIT, then HOLD
|
| Auto | Holds every new stable reading, again and again |
A-WAIT, A-HOLD
|
Options: delay (1–60 s), stable time (0.2–10 s), stable band and rearm threshold in digits of the last displayed position, minimum number of readings. Pressing HOLD again cancels a countdown or releases the held value. Statistics keep running while a value is held.
- Digital or analog dial view, rearrangeable (MENU → Layout), with custom colors.
- MENU → Appearance → Preset: Custom (your own look) or Hybrid (dark background, white scale, orange needle, amber digits). Choosing Hybrid keeps your Custom look, and choosing Custom brings it back; changing the look in Hybrid makes that your new Custom look. Reset element and Reset all confirm with a message.
- With Bar graph and Statistics off (MENU), the reading grows to 72 or 80 px and takes every free line.
- The function row shows the function's sign; units are spaced ("2.5 kΩ"), and REC appears while CSV logging runs.
- Bar graph and dial scaled to the meter: 25,000 counts on ZT703S, 66,000 on ZT706S.
- Statistics: MIN, MAX, AVG; reset from the panel. Trend chart, drawn from the first reading.
- Connect a Type K thermocouple to COM and V/Ω.
- Press F4 until the function shows the thermometer sign (DC mV → AC mV → Type K).
- Set MENU → Measurement → Cold junction to the temperature where the thermocouple wires meet the copper leads, 25.0 °C by default (←/→ by 0.1 °C, ↑/↓ by 1 °C, −50.0 … 100.0 °C).
- Temp units picks °C or °F.
OpenOSC measures the thermocouple voltage in DC mV, adds the EMF of the cold junction and converts the sum with the NIST ITS-90 tables.
- HOLD, REL, the trend, MIN/MAX/AVG and CSV logging work in temperature. The CSV value column is in °C; the unit and text columns follow the chosen unit.
- The dial picks a scale segment that fits the reading: 0–100, 100–300, 300–600, 600–1000 and further, and −100–0, −300–−100 below zero.
- Changing the unit or the cold junction starts a new period: HOLD, REL and the statistics are reset.
- The range follows the DC mV range. To change it, go back to DC mV, select the range and switch Type K on again.
- An open thermocouple is not detected in this mode.
If the meter chip stops answering, OpenOSC restarts its serial link up to 3 times, then power-cycles the chip with growing pauses and selects the function again. Readings taken before the function is active are dropped.
| Badge | Meaning |
|---|---|
LIVE |
Normal reading |
NO VALUE |
The meter shows dashes while it waits or changes range. Left out of statistics |
OVERLOAD |
OL on the display |
INVALID |
A reading that cannot be interpreted |
NO DATA / STALE
|
No data from the meter, or old data |
CSV logging in the panel writes readings to /openosc/LOGS/DMMnnnnn.CSV (Screenshots and Captures).