Oscilloscope
Two channels, 20 mV/div to 10 V/div, 10 ns/div to 20 s/div, with Auto, Normal and Single trigger, measurements, cursors, FFT, XY, MATH and Protocol Decoders.
| Key | Action |
|---|---|
| F1 Scale | Arrows change V/div (↑/↓) and time/div (←/→). Press again to switch CH1/CH2 |
| F2 Position | ↑/↓ move the channel's zero, ←/→ the horizontal position. Press again to switch CH1/CH2. Hold F2: center both channels |
| F3 Trigger | ↑/↓ move the trigger level. Press again to switch the trigger source CH1/CH2. Hold F3: level to 50 % of the signal |
| F4 Analyze / Cursor | Opens Analyze. With cursors on, F4 steps through the cursor lines and the arrows move the active one; MENU then opens Analyze |
| MENU | Channel panel: enable, coupling, probe, invert, position |
| HOLD | Run / Stop |
| AUTO | Auto Setup for both channels; with no signal it reports that instead of waiting |
In HOLD, ↑/↓ scale the held frame and ←/→ choose the time/div of the next capture; the held frame is redrawn at that scale at once. A held capture is never replaced by new data.
Enable, coupling (DC/AC), probe (×1, ×10, ×50, ×100, ×500, ×1000), invert and position, per channel. The probe factor is used for V/div, trigger levels, measurements and cursors.
Source, edge, level and mode Auto / Normal / Single in the trigger panel, plus Noise reject. Analyze → Rearm Single arms the next single shot. The trigger position (pre/post-trigger) is adjustable.
| Row | What it does |
|---|---|
| Measurements | Up to four measurements per channel: frequency, period, Vpp, RMS, AC RMS, mean, min, max, duty, pulses per frame and the hardware frequency counter |
| Cursors | Off, Time, Level or Time+Level (Frequency in FFT). Shows Δt, 1/Δt or ΔV |
| Display | Mode (YT or X-Y), samples (Peak / HD mean / Auto), interpolation (linear, sin(x)/x, spline), averaging, persistence (including infinite), grid, MATH and a reference waveform |
| Layout | Order of the waveform, the measurements and the soft-keys |
| Colors | Color schemes: Current, High contrast, Daylight, Amber, or custom RGB per element |
| Acquisition | Record depth and sample rate |
| Decoder | Protocol Decoders |
| Rearm Single, Save RAW, Save CSV | Actions; files go to /openosc/CAPTURES (Screenshots and Captures) |
| FFT spectrum | Up to 2048 points; Rectangular, Hann, Hamming or Blackman window; dBFS or linear |
| Center channels, Reset pan, Trigger 50% | Quick actions |
The first three measurements of each channel are shown below the waveform (by default frequency, Vpp and RMS); the fourth is on the next page.
-
FC is the live hardware frequency counter. It keeps updating in HOLD.
FCfmeans the count was filtered (bounce or narrow pulses removed);FC?means the count is not confirmed. - f~ / T~ are estimated from the spectrum of the record when there are fewer than eight points per period.
- A value that cannot be measured is shown as missing, never as zero.
Timebases of 200 ms/div and slower run in continuous Roll mode. Record memory is set in Settings → Device → Performance → Record memory. A record always fills the selected depth; a bar at the top shows where the visible part lies.
The sample rate depends on the profile: 100, 140 or 90 MS/s per channel.
OpenOSC is licensed under the GPL-3.0. Found a mistake on this page? Tell us in Discussions.