Skip to content

Signal Generator

Val edited this page Nov 17, 2026 · 4 revisions

Six waveforms with digit-by-digit frequency entry. The generator keeps running in the background while you use the oscilloscope or the multimeter.

Keys

Key Action
F1 Wave Waveform panel: shape, duty, level or amplitude
F2 Frequency Frequency editor
F3 Params Parameters panel: duty, level, presets, layout
F4 Output / HOLD Output on/off

Frequency editor: ←/→ select the digit, ↑/↓ change it, F2 again switches Hz / kHz / MHz, MENU applies, F4 cancels, F1/F3 apply and open the other panels.

Waveforms and limits

Waveform ZT703S max ZT706S max
Sine 344 kHz 10 MHz
Square 1 MHz (PWM) 2 MHz
Triangle 100 kHz 2 MHz
Half sine 129 kHz 2 MHz
Positive sine 294 kHz 2 MHz
Sawtooth (ramp) 100 kHz 200 kHz

Duty is set for square waves.

Level

  • ZT703S: level profiles Dedicated, Low, High or Custom DAC codes (0–4095). The preview line shows what sets the level, for example DAC 600-3600. Values are output codes, not calibrated volts. Square out: by default DAC below 1 kHz and PWM from 1 kHz, or PWM always. Preset Reference 1kHz: 1 kHz 50 % square.
  • ZT706S: amplitude in volts, 0.1 V steps; duty 1–100 % in 0.1 % steps.

At power-on

Settings → Device → Power → Generator at startup: Off (default, output off after power-on) or Restore last (the output turns on again if you last switched it on).

Layout

The order of the frequency, the preview and the soft-keys is set in Settings → Display → Generator layout or F3 → Layout. Changing it does not interrupt the output.

When the generator streams from the DAC, the oscilloscope's maximum sample rate is halved; the scope shows ADC max /2.

Clone this wiki locally