Skip to content

Finite volume flow

github-actions[bot] edited this page Nov 25, 2026 · 1 revision

Finite-volume flow

extensions/cfd/ solves laminar incompressible flow on a block of cells in two dimensions. It advances the Navier-Stokes equations in time with the PISO algorithm, as the OpenFOAM solver icoFoam does. A checked result is a numerical result. It does not establish engineering validity.

The flow in a lid-driven cavity at a Reynolds number of 400: the speed, and streamlines of the main vortex and the two corner vortices

examples/cavity_flow.mojo makes this picture. The lid of a 1 m cavity moves to the right at 1 m/s, and the Reynolds number is 400. The grid has 48 by 48 cells. The color is the speed, and the white lines are streamlines.

Modules

Module What it gives
kinds Side with WEST, EAST, SOUTH and NORTH. BoundaryKind with FIXED_VELOCITY and FIXED_PRESSURE. ConvectionScheme with UPWIND and CENTRAL. ThermalKind with FIXED_TEMPERATURE and INSULATED.
quantities DynamicViscosity64, KinematicViscosity64, ThermalDiffusivity64 and their units PASCAL_SECOND, CENTIPOISE, SQUARE_METER_PER_SECOND and CENTISTOKES
flow Grid, Boundary, FlowCase, FlowOptions and FlowSolver
heat BuoyantCase, BuoyantSolver, ThermalBoundary, fixed_temperature and insulated

Set up a case

A Grid is a block of equal rectangles. Cell (i, j) is column i from the west and row j from the south. A FlowCase holds the grid, the density and the dynamic viscosity of the fluid, and one boundary for each side. A new case has a wall on each side.

var grid = Grid(32, 32, Length64(1, METER), Length64(1, METER))
var flow = FlowCase(grid, Density64(1, KILOGRAM_PER_CUBIC_METER), DynamicViscosity64(0.01, PASCAL_SECOND))
flow.set_boundary(NORTH, fixed_velocity(Velocity64(1, METER_PER_SECOND), Velocity64(0, METER_PER_SECOND)))
Boundary Meaning
wall() The velocity is zero.
fixed_velocity(u, v) The velocity is fixed. An inlet has a velocity through the side. A moving wall has a velocity along it. The pressure has no gradient along the normal.
fixed_pressure(p) The pressure is fixed. The velocity has no gradient along the normal, so the fluid can leave or enter.

set_scheme(UPWIND) selects the upwind convection scheme. The default is CENTRAL. The central scheme is second order. The upwind scheme is first order, and it stays bounded on a coarse grid at a high Reynolds number.

Run the flow

FlowSolver(flow, options) starts with the fluid at rest. step(dt) advances one time step. run(dt, steps) advances several. run_to_steady(dt, tolerance, budget) advances until the largest change of a velocity in one step is below the tolerance. It returns the number of steps.

var solver = FlowSolver(flow^, default_options())
var steps = solver.run_to_steady(Duration64(0.1, SECOND), Velocity64(1e-5, METER_PER_SECOND), 2000)
var speed = solver.velocity_x(16, 16)
var push = solver.pressure(16, 16)
Result Holds
velocity_x(i, j), velocity_y(i, j) The velocity at the center of a cell
pressure(i, j) The pressure at the center of a cell
elapsed(), change() The time, and the largest change of a velocity in the last step
imbalance() The largest net flux that leaves a cell, for a block one meter thick
u, v, p, flux_x, flux_y The raw fields. p is the pressure over the density.

If no side has a fixed pressure, the pressure is free by a constant. The solver then holds it near zero in the cell at the south-west corner.

The time step is implicit. For a transient result, keep the Courant number u Δt / Δx near one or below. For a steady result, a Courant number of 5 gives the same flow in fewer steps.

FlowOptions(correctors, sweeps, pressure_tolerance, pressure_iterations) sets the inner iterations. default_options() gives 2 correctors, 50 sweeps, a tolerance of 1e-8 and a budget of 10000 iterations.

Carry heat

Air between a hot wall and a cold wall at a Rayleigh number of 100000: the temperature, and the streamlines of the convection

examples/buoyant_cavity.mojo makes this picture. The left wall is hot and the right wall is cold. The grid has 40 by 40 cells. The Nusselt number of the hot wall is 4.617. The benchmark of de Vahl Davis gives 4.519.

extensions/cfd/heat.mojo adds a temperature that the flow carries, and the buoyancy that the temperature gives. A BuoyantCase holds a FlowCase and the thermal properties of the fluid. A new case has every side insulated.

var buoyant = BuoyantCase(flow^, ThermalDiffusivity64(2.2e-5, SQUARE_METER_PER_SECOND), ThermalExpansion64(3.4e-3, PER_KELVIN), Acceleration64(9.80665, METER_PER_SECOND_SQUARED), Temperature64(293.15, KELVIN))
buoyant.set_thermal_boundary(WEST, fixed_temperature(Temperature64(303.15, KELVIN)))
buoyant.set_thermal_boundary(EAST, fixed_temperature(Temperature64(283.15, KELVIN)))
var solver = BuoyantSolver(buoyant^, default_options())
var steps = solver.run_to_steady(Duration64(0.1, SECOND), TemperatureDifference64(1e-5, KELVIN_DIFFERENCE), 5000)
var warm = solver.temperature(3, 8)
Thermal boundary Meaning
fixed_temperature(t) The side has a fixed temperature.
insulated() No heat crosses the side by conduction. Fluid that enters through it has the temperature of the cell beside it.

The model is the approximation of Boussinesq. The fluid has one density in every term but the weight. A cell at a temperature T has an upward acceleration of g β (T - T₀). Here β is the expansion coefficient and T₀ is the reference temperature. The gravity acts along -y. The approximation holds for a small temperature range.

Each time step has three parts. First the solver sets the buoyancy of each cell from its temperature. Then FlowSolver advances the flow by one PISO step. Last the solver advances the temperature with the new face fluxes, implicit in time.

BuoyantSolver has step, run_to_steady, temperature(i, j) and change(). Its field flow is the FlowSolver, with the velocities and the pressure. wall_gradient(side) gives the mean temperature gradient at a side of fixed temperature. The Nusselt number of a wall is this gradient times a length over a temperature difference.

FlowSolver has a body acceleration per cell in its fields force_x and force_y. They are zero unless a caller sets them. The solver takes the force at each face, next to the pressure gradient, so the two can balance there. At a wall the pressure gradient along the normal equals the force. So a fluid in stable layers stays at rest, and its pressure is hydrostatic. OpenFOAM gets the same balance with its pressure p_rgh.

The model follows the OpenFOAM solver buoyantBoussinesqPimpleFoam. The code is original.

The method

The cells hold the velocity and the pressure at their centers. The faces hold the volume flux. Each time step has these parts:

  1. The momentum predictor. It is implicit Euler in time, with the old face fluxes and the old pressure gradient. Gauss-Seidel sweeps solve it.
  2. The pressure correctors. Each corrector writes the velocity as H / A - (1 / A) ∇p. It takes the face fluxes from H / A. It solves the pressure equation ∇·((1 / A) ∇p) = ∇·(H / A) by conjugate gradients. Then it corrects the fluxes and the velocity.

The face flux comes from H / A and the pressure difference between the two cells of the face. It does not come from an interpolated velocity. This is the method of Rhie and Chow. It keeps the pressure free of the checkerboard mode on a grid that holds both variables at the cell centers.

The diffusion term uses the difference of the two cell values over their distance. At a side of fixed velocity it uses the half distance to the face.

The equations, the PISO loop and the names H and A follow icoFoam. The code is original and shares no source with OpenFOAM.

Validation

Each row is a test in tests/test_cfd_flow.mojo or tests/test_cfd_heat.mojo.

Case Reference Result
Channel between two walls, 3 by 6 cells, pressure drop along it The exact solution of the finite-volume equations: G y (H - y) / (2 μ) + G Δy² / (8 μ) Below 1e-8 m/s, with both schemes
The same channel, pressure Linear along the channel Below 1e-8 Pa
The same channel, flow rate G H³ / (12 μ) times 1 + 2 / n² for n cells across Below 1e-7
Lid-driven cavity, Reynolds number 100, 8 cells a side Ghia, Ghia and Shin, tables I and II, 12 values 0.19 of the lid speed
The same cavity, 16 cells a side The same 12 values 0.029 of the lid speed
The same cavity, 8 and 16 cells a side OpenFOAM icoFoam on the same grid, scheme and time step, each cell 0.019 and 0.009 of the lid speed
Duct with an inlet and an outlet, upwind scheme Outlet flux equals inlet flux Below 1e-8 m²/s
Fluid at rest Stays at rest Exact
Cavity with a hot and a cold wall, no gravity A linear temperature and a Nusselt number of one Below 1e-7
The same cavity at a Rayleigh number of 1000, 12 cells a side de Vahl Davis: a Nusselt number of 1.118, and peak velocities of 3.649 and 3.697 0.9%, 1.3% and 2.5%
The same case OpenFOAM buoyantBoussinesqPimpleFoam on the same grid, scheme and time step, each cell 0.0013 K, 0.15% in the Nusselt number, 0.09 m/s
The same cavity at a Rayleigh number of 10000, 12 cells, upwind scheme de Vahl Davis: a Nusselt number of 2.243 Below 12%
The same case buoyantBoussinesqPimpleFoam with the upwind scheme, each cell 0.0024 K, 0.5% in the Nusselt number, 0.62 m/s
Warm fluid above cold fluid, with gravity At rest, with a linear temperature Velocities below 1e-6 m/s
Duct with a warm inlet and insulated walls The inlet temperature in every cell Below 1e-6 K

assets/cfd/make_cavity_reference.py and assets/cfd/make_convection_reference.py run OpenFOAM 2406 in Docker and write the OpenFOAM rows. They use the same grid, scheme and time step as the tests.

The time step matters. From a Courant number of 0.5 to 0.1, the steady flow of icoFoam changes by 0.027 of the lid speed. Its face flux correction depends on the time step. The port has no such term. The largest differences are in the cells at the corners. There OpenFOAM balances the buoyancy with the pressure at the faces, and the port adds it in the cells.

At a Rayleigh number of 10000 with the central scheme, the Nusselt number is 2.325 with 16 cells a side and 2.280 with 24. The benchmark value is 2.243. These grids are too slow for a test under coverage, so no test holds these values.

With 32 cells a side, the cavity has u = -0.2064 at y = 0.484 on the vertical center line. Ghia, Ghia and Shin give -0.2058 at y = 0.5. That grid is too slow for a test under coverage too.

Errors

Every function raises Error for input it cannot use.

Case Functions
A cell count is not positive, the grid has more than 1048576 cells, or a size is not positive and finite Grid
A cell is out of range Grid.cell, the result accessors
A density or a viscosity is not positive and finite FlowCase
A side, a boundary or a scheme is not valid set_boundary, set_scheme, FlowSolver
A count or a tolerance of the options is not positive FlowOptions
A time step is not positive and finite step, run, run_to_steady
A diffusivity is not positive, or a thermal property or a thermal boundary is not valid BuoyantCase, set_thermal_boundary, BuoyantSolver
A wall gradient is asked of an insulated side wall_gradient
The pressure solution does not converge within its budget step, run, run_to_steady
The flow is not steady within the step budget run_to_steady

Limits

  • The grid is one block of equal rectangles in two dimensions. It has no grading and no obstacles.
  • The flow is laminar and incompressible, with constant properties. It has no turbulence model. The buoyancy is the approximation of Boussinesq, with the gravity along -y.
  • The buoyancy of a step comes from the temperature at its start. Keep the time step below the period of the buoyancy oscillation, 1 / sqrt(g β dT/dy).
  • Each side has one boundary along its whole length.
  • A side of fixed pressure takes the velocity of the cell beside it. So an inflow through it has no fixed direction.
  • The time scheme is implicit Euler, which is first order.

References

  • Issa, "Solution of the implicitly discretised fluid flow equations by operator-splitting", Journal of Computational Physics 62, 1986: the PISO algorithm.
  • Rhie and Chow, "Numerical study of the turbulent flow past an airfoil with trailing edge separation", AIAA Journal 21, 1983: the face flux.
  • Jasak, "Error analysis and estimation for the finite volume method with applications to fluid flows", PhD thesis, Imperial College, 1996: the OpenFOAM discretization.
  • Ferziger and Peric, "Computational Methods for Fluid Dynamics", 3rd edition, 2002: chapters 7 and 8.
  • de Vahl Davis, "Natural convection of air in a square cavity: a bench mark numerical solution", Int. J. Numer. Methods Fluids 3, 1983.
  • Ghia, Ghia and Shin, "High-Re solutions for incompressible flow using the Navier-Stokes equations and a multigrid method", Journal of Computational Physics 48, 1982.
  • White, "Viscous Fluid Flow", 3rd edition, 2006: plane Poiseuille flow.

Home