Leak Detection
Available in 0.3.0. This is a hint, not an alarm or a confirmed leak. The receiver sees hourly pulse totals only, not instantaneous flow. A dripping tap using less than one pulse per hour is invisible to these rules. Scheduled irrigation, pool filling, and normal overnight use can trigger them. Check the physical meter and household usage before drawing conclusions; adjust the night window to avoid irrigation schedules.
Detection is enabled by default for configured meters only, never neighbours. It needs supported clear-format usage intervals; encrypted meters cannot provide this hint. No litres-per-count calibration is required.
These options work in add-on configuration and standalone JSON. Set timezone to
your local IANA zone, for example Australia/Brisbane or Australia/Sydney.
| Option | Default | Meaning |
|---|---|---|
leak_detection |
true |
Enable possible-leak discovery and evaluation. false removes its retained discovery and hint topic on reconnect/restart. |
leak_continuous_hours |
24 |
Positive-flow coverage horizon, integer 1–168 hours (within the existing eight-day history). |
leak_night_start |
"01:00" |
Inclusive local start time, strict 24-hour HH:MM. |
leak_night_end |
"05:00" |
Exclusive local end time, strict HH:MM; must differ from the start. A start later than the end crosses midnight. |
leak_night_min_pulses |
1 |
Minimum pulses per observed night interval, integer 1–65535. |
Continuous flow: every observed hourly interval in the last N hours must have more than zero pulses, and at least 80% of those hours must be observed. With the default 24-hour horizon this needs at least 20 observations. Missing hours count as neither flow nor zero. Once triggered, this reason stays active through gaps and clears when a new observed zero-flow interval arrives. A later qualifying run can trigger it again. Elapsed hours are measured in UTC, including across DST.
Night flow: every observed interval ending inside the local night window must
have at least leak_night_min_pulses, with at least three observed intervals.
The rule decides only when the window is complete, so the hint arrives at the
end of the window. With at least three observations, all must meet the threshold
to activate this reason; any below the threshold clears it. Daytime zeroes and
nights with fewer than three observations leave the previous state unchanged.
The end time is exclusive; for example, an interval
ending at exactly 05:00 is outside the default window. Midnight-crossing windows
belong to their start date. Repeated DST hours are distinct observations, while
skipped hours are not invented. An ambiguous end time uses its later occurrence.
Either reason makes the binary sensor ON. If both are active, the continuous-flow
reason is displayed first; clearing it can leave night flow active. Rule state
survives restarts. Changing rule options or timezone recomputes it from the
existing bounded history.
Each configured meter has binary_sensor.taggle_<id>_possible_leak, with device
class problem. MQTT discovery uses default_entity_id, so existing entity
renames are preserved. Availability follows the meter's usage sensors: receiver
online, a valid frame within three hours, and decoded counts available. An OFF
sensor means no qualifying hint, not proof that the plumbing is leak-free.
With the default MQTT prefix, taggle/<id>/leak carries state (ON or OFF)
and these attributes. It is retained and republished after reconnects; rule
checkpoint fields stay private in the store.
| Attribute | Meaning |
|---|---|
reason |
continuous flow for 24 h (or the configured N), night flow, or null when OFF. |
hours_with_flow_last_24h |
Observed intervals with positive pulses in the preceding 24 elapsed hours. |
longest_zero_run_hours |
Longest consecutive observed zero run in those 24 hours; gaps break the run. |
night_pulses |
Sum of pulses in the most recent observed night window, including a window still in progress. Zero when no night intervals remain in history. |
observed_hours |
Number of observed intervals in the preceding 24 elapsed hours. |
last_evaluated |
ISO-8601 UTC evaluation time. Periodic refreshes leave the radio last_seen unchanged. |
Device-based cards discover the binary sensor through the entity registry, including renamed entities. For an explicit entity mapping, append:
entities:
# Keep your existing mappings, then add your own meter's actual entity ID:
possible_leak: binary_sensor.taggle_123456_possible_leakFor a list of entity IDs, add that binary sensor to the list. When its Home
Assistant state is on, a small Possible leak badge shows the reason. OFF,
unknown, unavailable, and missing sensors show no badge.
See the wiki Entities reference and Configuration reference for the surrounding receiver settings and entities.
ha-taggle is experimental, receive-only and unofficial. It is not affiliated with Taggle Systems or any council or utility. Only receive your own meter, and never touch the utility's equipment. All IDs in this wiki are fictional. · Repository · Report an issue · Glossary
Start here
- Home
- Getting started
- Check your meter
- Finding your meter
- Meter types and pulse sizes
- Hardware and antennas
- Tested hardware
Setup
Using it
Reference and optional background
- Entities reference
- Configuration reference
- How it works
- Protocol
- Privacy and legal
- Glossary
- AI disclosure
Help