Repository navigation
Install Esp32 Gen1
Kegtron Gen 1 (KT-100, KT-200) devices only speak Bluetooth Low Energy — there's no WiFi/Ethernet/cloud path on the device itself (unlike Kegtron Pro). To get their readings into Kegwall you need either:
- A host running this app within direct Bluetooth range — the verified path. See docs/install/raspberry-pi.md#direct-ble-setup-gen-1-devices. Prefer this if you can.
- An ESP32 (or similar) running a BLE-to-MQTT bridge, covered on this page — for devices out of direct range of the machine running the app, relayed over your existing MQTT broker instead.
src/server/ingest/gen1/mqttSource.ts carries a long header comment recording exactly
what was checked (2026-07-28): the task brief for this integration asked for the message
shape to be verified against Theengs Decoder's documented Kegtron device profile. That
verification found Theengs Decoder has no built-in Kegtron device profile at all —
neither at decoder.theengs.io/devices/KEGTRON.html (404s) nor in the decoder's own
GitHub source tree (123 device files checked, none for KT-100/KT-200/Kegtron).
So the parser in this app does not target a real, confirmed Kegtron MQTT payload. Instead
it targets Theengs' general MQTT envelope conventions (verified against real Theengs
device definitions) combined with the Kegtron-specific property names used by the
kegtron-ble Home Assistant integration's BLE parser (volume_start, volume_dispensed,
keg_size, in liters). This is a documented best-effort inference, not a confirmed
real-world payload shape. It has not been tested against a real ESP32 + OpenMQTTGateway
(or Theengs Gateway) + Kegtron Gen 1 deployment. If your bridge's actual JSON doesn't
match what's below, readings simply won't appear — check your broker's raw messages
(mosquitto_sub -t 'home/TheengsGateway/#' -v or similar) against the accepted keys, and
see the last section for what a mismatch usually needs.
The source subscribes to {gen1TopicPrefix}/# (default home/TheengsGateway, matching
Theengs Gateway's own default topic — configurable in Settings -> Sources -> "Gen 1
topic prefix") and inspects every JSON message it receives on that tree. A message is
recognized as a Kegtron reading only if all of the following hold (cited directly from
parseKegtronMqttMessage/isKegtronMessage/numberField in
src/server/ingest/gen1/mqttSource.ts):
-
Device identification — one of:
- top-level
model_idequal (case-insensitive) tokt-100,kt-200,kt100, orkt200, or - top-level
modelcontaining the substringkegtron(case-insensitive), or - top-level
brandcontaining the substringkegtron(case-insensitive).
- top-level
-
A valid MAC address, in
mac(oridas a fallback) — either colon-separated (AA:BB:CC:DD:EE:FF, any case) or 12 bare hex digits with no separators. -
Both volume fields present as numbers — checked in this exact order, first key that exists as a finite number wins:
- Start volume:
volume_start(assumed liters, converted to mL) → falls back tovolStartMl,vol_start_ml,volStart,vol_start(assumed already mL, no conversion). - Dispensed volume:
volume_dispensed(liters) → falls back tovolDispensedMl,vol_dispensed_ml,volDispensed,vol_disp(mL).
If either is missing entirely, the message is silently dropped (not treated as an error — the topic tree may carry other devices' messages too).
- Start volume:
Optional fields:
-
Keg size:
keg_size(liters) → falls back tosizeMl,keg_size_ml,kegSizeMl(mL). Null if none present. -
Port index (0-based; matters for KT-200's two ports):
port_indexorportIndex, a non-negative integer. Defaults to0if absent — correct for KT-100 (genuinely single-port) and a reasonable fallback for KT-200. -
Model name for display:
model, falling back tomodel_id.
Example payload the parser accepts:
{
"model_id": "KT-200",
"mac": "AA:BB:CC:DD:EE:FF",
"volume_start": 18.927,
"volume_dispensed": 2.365,
"keg_size": 18.927,
"port_index": 0
}- Flash your ESP32 with OpenMQTTGateway (BLE-to-MQTT gateway mode) or Theengs Gateway, pointed at your MQTT broker. Follow that project's own flashing/config docs — this repo doesn't ship firmware.
- Configure the bridge's MQTT topic prefix to match what you'll set below (or note its
default and use that as
gen1TopicPrefixinstead — either direction works, they just need to match). - In Kegwall's admin UI: Settings -> Sources:
-
MQTT broker URL —
mqtt://host:1883(ormqtts://host:8883for TLS), the same broker your bridge publishes to. - MQTT username / password — if your broker requires auth.
-
Gen 1 topic prefix — must match your bridge's publish topic prefix (default
home/TheengsGateway).
-
MQTT broker URL —
- Save. Check the connection doctor (Settings → Diagnostics) — it reports
subscribed to {prefix}/#once connected, or a specific error (auth failure, connection refused, etc.) if not.
Because the payload shape is unverified, the most likely failure mode is a real bridge
publishing field names slightly different from what's listed above (e.g. a decoder that
uses vol_start in mL instead of volume_start in liters is already covered by the
fallback list — but something entirely different, like a nested object instead of flat
fields, is not). If your bridge's JSON has the right shape (flat top-level fields) but
different names, the fix is a one-line addition to numberField()'s key lists in
src/server/ingest/gen1/mqttSource.ts — it isn't a structural rewrite. If you get this
working against real hardware, consider that a valuable fact worth recording back into
this file and that source's header comment for the next person.
Mirrored from docs/install/esp32-gen1.md. Edit the repo copy; this page is regenerated from it.
- Admin Dashboard
- Beers
- Cleaning And Pours
- Customization
- Insights
- Install Android Tablet
- Install Display Agent
- Install Docker
- Install Esp32 Gen1
- Install Mini Pc
- Install Moving To Github
- Install Native Wall
- Install Raspberry Pi
- Install Unattended Debian
- Kegtron Pro Ble Format
- Menu And Kiosk
- People
- Recovery
- Settings
- Setup Face Sign In
- Setup Home Assistant
- Setup Kegtron Cloud
- Setup Motion Sensors
- Suppliers