Skip to content

File Formats

aznursoy edited this page Jun 19, 2026 · 2 revisions

File Formats

This page documents the input and output file structures the tool uses. Understanding the frame layout of the multi-frame TIFF stacks is the key to using the tool's outputs correctly.


Input images

Type Extension Notes
Multi-frame TIFF .tif, .tiff Contains the FRET, Donor, and Acceptor channels as separate frames.
Zeiss CZI .czi Converted automatically on load to a multi-frame TIFF.

CZI conversion

When a .czi file is loaded, the tool extracts the channels into a 3-frame TIFF (FRET, Donor, Acceptor) and preserves the original raw intensity values (no rescaling). A 4th channel is included when present for S3/S4 calculations.


Segmented stacks (Segmentation output)

Saved into a segmented/ folder next to the source image, named:

outline_segmented_<name>.tif      # when "Generate outlines only" is on
whole-cell_segmented_<name>.tif   # when filled masks are used

Frame layout:

Frame Content
0 Segmentation label mask (0 = background, 1..N = cell labels)
1 FRET channel
2 Donor channel
3 Acceptor channel (present for 4-frame data)

This is exactly the layout the Bleed-Through and FRET tabs expect. Raw intensities of every channel are preserved so downstream calculations are accurate.


Bleed-through parameters (bt_params.json)

Written by Save Parameters in the Bleed-Through tab to the default location and copied into each input image directory. Structure:

{
  "s3_s4_enabled": false,
  "donor_params":    { "...": "model type, coefficients, sigma, sampling, selected_fit_model, fit_results" },
  "acceptor_params": { "..." },
  "s3_params":       { "..." },
  "s4_params":       { "..." }
}

Each channel block records the fitting model, its coefficients, the processing settings, and the selected model so the fit can be restored exactly. Load it with Load Parameters.


FRET outputs

Output Format Location / how
Efficiency maps (one per formula) 32-bit float TIFF FRET_Analysis_Results/<name>_<formula>_efficiency.tif, when efficiency saving is enabled
Aggregate statistics CSV Exported from the aggregate statistics table
Figures (maps, histograms, box plots) PNG / PDF Save button on any plot or its pop-out window

Efficiency maps store percentage values (0–100%) as floating-point pixels, with background and excluded pixels set to 0.


Notes

  • The label mask must be frame 0 of any stack you feed to the Bleed-Through or FRET tabs. If you build stacks outside the tool, follow the layout above.
  • 3-frame stacks (mask, FRET, Donor/Acceptor) are sufficient for S1/S2; 4-frame stacks are required for S3/S4.
  • See Workflows and Data Flow for how these files move between tabs.