The main control interface for your ventilation system.

Overview

The HVAC Fan Card is a custom Lovelace card that provides comprehensive control over your FAN device. It displays real-time data from 31DA messages and offers:

  • Manual control – Adjust fan speed directly
  • Automation status – See Humidity Control, CO2 Control, Temp Control activity
  • Zone monitoring – View zone states and demands
  • Control mode – Switch between Manual, Extras Auto, and Unit Auto modes
  • Parameter editing – Edit 2411 parameters in settings mode

The layout will adapt if features are enabled or disabled like humidity control, CO2 control, or temp control.

Adding the Card

Manual YAML Configuration

Add to your Lovelace dashboard:

type: custom:hvac-fan-card
device_id: 32:153289  # Your FAN device ID
name: HVAC Fan Card

Card Editor (UI)

  1. Edit your dashboard
  2. Click Add Card
  3. Search for Hvac Fan Card
  4. Select your FAN device
  5. Configure display options

Card Features

Fan Speed Buttons

  • Low / Medium / High – Manual speed selection (enters manual override)
  • Auto – Toggle between Extras Auto and Unit Auto modes
  • Away – Set the FAN to away/minimum ventilation mode

Control Mode Badge

The card displays your current control mode:

Badge Meaning Next Action
Manual You selected a speed Press Auto to resume automation
Extras Auto Ramses Extras automation active Humidity/CO2 Control can adjust speed
Unit Auto FAN's built-in auto mode Extras automation bypassed

Zone Status Display

When zones are configured:

┌─────────────────────────┐
│  Zones:                 │
│  ● Bathroom: Open 85%   │ ← Active demand
│  ○ Bedroom: Closed 15%  │
│  ● Office: Open 90%     │ ← Active demand
│  ○ Kitchen: Closed 15%  │
└─────────────────────────┘
  • ● – Zone is open with active demand
  • ○ – Zone is closed or at minimum position
  • Percentage – Current valve position (from zone adapter)

Transport State Indicator

Shows whether your FAN device is online:

  • 🟢 Green dot – Device is online and responding
  • 🔴 Red dot – Device is offline (commands may be queued)

The online/offline text has been replaced by the coloured dot; hover it for the full status. Based on binary_sensor.transport_state_{device_id} entity.

Corner layout follows the humidity pairing

The four corner panels show outdoor (top-left), indoor (top-right), exhaust (bottom-left) and supply (bottom-right) values. Where the outdoor humidity row (RH% → absolute humidity) is rendered depends on the configured absolute-humidity pairing in Sensor Control:

  • Outdoor pairing (internal outside flow, external_temp, external_abs): the humidity row sits in the top-left panel with the outdoor temperature, and the feature-status rows (Temp →, Balance →, CO2 →) stay top-right.
  • Supply pairing (internal_supply, or an external temperature entity that resolves to the FAN's own supply_temp): the humidity row moves to the bottom-right panel next to the supply temperature it is calculated with, and the feature-status rows move to the top-left. Zone/area rows stay top-right.

This reflects where the RH is actually measured: on units whose "outdoor" RH sensor sits in the supply duct (see Sensor Control), the humidity belongs next to the supply temperature.

The bottom-centre stats block is kept compact — fan mode, control source and the connection dot on the top line, exhaust/supply fan speeds and flow rates on the bottom line — so it does not cover the corner values.

How to Use

Everyday Control

Quick ventilation boost:

  1. Press High for immediate maximum ventilation
  2. Press Auto when done to return to automation

Leaving home:

  1. Press Away to set minimum ventilation
  2. Press Auto when returning to resume normal operation

Working with Automation

When Humidity Control triggers:

  • The card shows which zone caused the demand
  • Fan speed increases automatically
  • Zone valve opens to maximum position
  • Press Auto at any time to override and take manual control

When CO2 Control triggers:

  • Similar to Humidity Control but with higher priority
  • If both are active, CO2 wins (safety priority)

When Temp Control triggers:

  • The card shows a "Temp control" button in the bypass row
  • A status indicator (top-right) shows: Off / On / Cooling / Heating retention
  • During cooling: bypass opens, fan speed increases (coordinated via arbiter)
  • During heating retention: bypass closes to retain warmth
  • Pressing the temp control button toggles the feature on/off
  • Manual bypass buttons automatically turn off temp control first

Understanding the Modes

Manual Mode:

  • Fan stays at your selected speed
  • Humidity and CO2 automations are suspended
  • Persists until you press Auto or the timeout expires

Extras Auto Mode:

  • Ramses Extras features (Humidity/CO2 Control) are active
  • Fan speed adjusts based on sensor demands
  • You can still press speed buttons to temporarily override

Unit Auto Mode:

  • FAN's own internal logic controls ventilation
  • Ramses Extras automation is bypassed
  • Useful when you want the FAN to behave "normally"

Advanced Configuration

Card Editor Options

Option Purpose
entity The FAN entity to control
features List of feature cards to include
show_zones Display zone status panel
show_diagnostics Show diagnostic entities

Multiple FANs

If you have multiple FAN devices, add multiple cards:

# Main floor
type: custom:hvac-fan-card
entity: fan.ramzes_32_153289

# Second floor
type: custom:hvac-fan-card
entity: fan.ramzes_32_153290

Troubleshooting

"Card doesn't appear in add card UI"

  1. Ensure Ramses Extras is properly configured
  2. Clear browser cache (Ctrl+Shift+R or Cmd+Shift+R)
  3. Check browser console for JavaScript errors

"Buttons don't respond"

Check:

  • Device transport state indicator – Red means offline
  • Are you in Manual mode with a stuck override? Press Auto
  • Check Home Assistant logs for errors

"Zone status not showing"

  • Zones must be configured in FAN Configuration first
  • Ensure the show_zones option is enabled
  • Zone entities must exist in Home Assistant

"Auto button cycles through modes unexpectedly"

This is expected behavior:

  1. First press → Extras Auto (if in Manual)
  2. Second press → Unit Auto
  3. Third press → Back to first mode

The button cycles through available modes, showing the current mode in the badge.

Related Cards

FAN Map Card

A separate observability card showing:

  • Complete FAN topology (zones, areas, REMs)
  • Sensor values and mappings
  • Valve positions and calibration status
  • Test bench actions (with safety confirmations)

Add it alongside your HVAC Fan Card for complete control and visibility.

Settings Mode

The HVAC Fan Card includes a settings mode (gear icon) to:

  • Edit 2411 parameters directly
  • View sensor source mappings
  • Configure area sensors
  • Adjust Humidity Control settings (min/max RH, absolute humidity offset)
  • Toggle Spike: Ignore Outdoor – when enabled, indoor humidity spikes trigger extraction regardless of outdoor absolute humidity (useful for bathroom extraction)
  • Toggle per-area Spike: Ignore Outdoor – same option per area sensor, so individual rooms (bathroom, kitchen) can independently ignore outdoor conditions
  • Access advanced configuration options

Back to: Home | Prev: FAN Map | Next: Floorplan Helper