Skip to content

Plugin NICS Placer

Hiromichi Yokoyama edited this page Oct 19, 2026 · 8 revisions

Plugin: NICS Placer

NICS Placer detects rings in 3D molecular structures and calculates optimal positions for Nucleus-Independent Chemical Shift (NICS) ghost atom probes (Bq), supporting standard NICS(0)/NICS(1) placements as well as 2D and 3D probe grids for spatial magnetic shielding studies.

Repository moleditpy_nics_placer
Author HiroYokoyama
Supported OS Windows, macOS, Linux, WSL
Supported Python >=3.9, <3.15
Supported MoleditPy >=5.0.0, <6.0.0
First-party plugin license LGPL-3.0-or-later
Menu location 3D Edit ▸ NICS Placer... and 3D Edit ▸ NICS Grid (2D, 3D)...
Extra dependencies None (uses RDKit, PySide6 from the MoleditPy environment)

See Official Plugins for the full catalogue.


1. Overview and placement types

NICS is a computational probe of aromaticity based on magnetic shielding tensors calculated at ghost atom sites. The plugin offers two dedicated modes:

Single/Ring Probe Mode (3D Edit ▸ NICS Placer...)

  • NICS(0): Places a ghost probe at the geometric center (centroid) of the ring in the ring plane.
  • NICS(1)±: Calculates probe positions displaced along the ring's surface normal above and below the ring plane. The normal is computed via Singular Value Decomposition (SVD) best-fit plane.
  • Adjustable probe offset: Customize the probe height from the default $1.0\ \mathrm{\AA}$ (e.g. $0.5\ \mathrm{\AA}$, $1.5\ \mathrm{\AA}$, $2.0\ \mathrm{\AA}$) or adjust heights to clear bulky substituents on puckered or non-planar macrocycles.

Grid Probe Mode (3D Edit ▸ NICS Grid (2D, 3D)...)

  • 1D/2D planar grids: Create a 2D rectangular grid of ghost probes across a molecular plane to generate 2D NICS contour maps.
  • 3D spatial boxes: Define a 3D bounding box of regularly spaced probes for Iso-Chemical Shielding Surfaces (ICSS).

2. Ring detection and planar orientation

  • Automatic ring perception: Identifies aromatic, antiaromatic, and non-aromatic rings (5-membered, 6-membered, and larger cycles) using RDKit's SSSR (Smallest Set of Smallest Rings).
  • Consistent face alignment: Ring normal vectors are automatically aligned against a global molecular reference direction so that "NICS(1) above" refers to the identical face across all fused rings (e.g. naphthalene, anthracene, porphyrins).
  • Ring planarity column: Reports the Root Mean Square (RMS) deviation of ring atoms from the SVD best-fit plane, alerting the user with a warning badge ($\Delta &gt; 0.1\ \mathrm{\AA}$) when non-planarity makes a perpendicular distance ill-defined.

3. Interactive 3D preview

In the 3D viewport, each probe position is drawn as a sphere whose colour gives its state:

  • Yellow: available, not staged. Click it to stage it.
  • Red: staged. Click again to unstage; Apply places a ghost atom at every red sphere.
  • Green: a ghost atom already sits there. Clear All Probes removes it.

The table buttons stage NICS(0) or NICS(1)± for the selected rings (all rings when none is selected), and Place All stages and places everything at once.

The probes follow the molecule. Loading a file, undo/redo, and editing atoms in place (dragging, alignment, geometry optimisation) all recompute the rings and probe positions, in both the NICS Placer and the NICS Grid window. Ghost atoms that match none of the current probe positions — probes placed at an earlier probe height, grid probes, or ghosts from another tool — are not drawn, so a notice above the table counts them.

A probe is never placed on top of an existing ghost atom: pressing Place Grid twice, or a grid point landing on a NICS(0) probe, skips those positions instead of stacking a second ghost there.


4. Integration with DFT input generators

Each probe is a dummy atom carrying a custom_symbol property, which the input generators write into the coordinate block. Choose the label for the program you are preparing:

  • Bq for Gaussian Input Generator Pro.
  • H: for ORCA Input Generator Pro. ORCA does not recognise Bq. An H: ghost keeps a full hydrogen basis, which perturbs the shielding it measures, so set it to Bare in the generator's Per-atom Basis box.

The label is shared by both windows and saved with the project. Changing it in either window relabels every probe already placed and updates the other window, so one molecule never carries a mix of Bq and H:.


Usage notes

Ring-plane placement requires at least three points that define a plane. Probe coordinates, grid spacing and extents must be valid finite values. Probe insertion preserves existing conformers.


5. See also


This page documents NICS Placer v3.0.0, and was last updated on 2026-10-19. See REGISTRY/plugins.json for the current version.

Clone this wiki locally