Skip to content

plat 288

github-actions[bot] edited this page Sep 20, 2026 · 1 revision

← Pulse platform issue index

PLAT-288 — Inverted Workshop scripted fast-path mode gate

Coordination Value
Ticket state Local fix tested; deployment reverify pending
Last synchronized 2026-09-05
Origin build-in-public PUL-FF23BCD5

execute_step(fast_path_only=true) advertises Workshop-only execution of a saved script with no LLM fallback. The executor instead rejected the request when the current mode was Workshop, before checking effective scripted configuration or the saved file. It also returned that rejection as a successful tool result. This is separate from PLAT-280's plan-step migration fix.

The executor now allows Workshop mode and returns a tool error for Run mode. Downstream effective scripted-mode, saved-file and SavedScriptOnly checks remain unchanged: missing/failed scripts do not gain an LLM fallback. No workflow code or schedule was executed as part of this repair.

Verification: TestWorkshopFastPathModeGate checks Workshop, Run, unknown mode and ordinary execution, and verifies the actual executor uses the gate. The focused Test.*Scripted suite also passes. These are local source tests, not a fresh deployed execution of the reported preflight step.

The exact SQLite finding is resolved for internal tracking with its prior record preserved in a platform_tracking_resolved event. Deployment verification remains pending; no historical run result was changed.

Clone this wiki locally