Repository navigation
Control humidifier
Control catalogue · Documentation home

Minimal field JSON:
{
"id": "humidifier",
"type": "humidifier",
"name": "Humidifier"
}Full field JSON:
{
"id": "humidifier",
"type": "humidifier",
"name": "Humidifier",
"default": {
"state": "OFF",
"humidity": 50,
"current_humidity": null,
"mode": "normal"
},
"controls": [
{
"key": "state",
"type": "switch",
"label": "ui_111",
"command": "",
"on": "ON",
"off": "OFF"
},
{
"key": "humidity",
"type": "slider",
"label": "ui_129",
"command": "humidity",
"min": 0,
"max": 100,
"step": 1
},
{
"key": "mode",
"type": "select",
"label": "ui_103",
"command": "mode",
"options": [
"normal",
"eco"
]
}
],
"ha": {
"command_topic": "$command",
"state_topic": "$state",
"state_value_template": "{{ value_json.state }}",
"target_humidity_command_topic": "$command:humidity",
"target_humidity_state_topic": "$state",
"target_humidity_state_template": "{{ value_json.humidity }}",
"current_humidity_topic": "$state",
"current_humidity_template": "{{ value_json.current_humidity | default('', true) }}",
"mode_command_topic": "$command:mode",
"mode_state_topic": "$state",
"mode_state_template": "{{ value_json.mode }}",
"modes": [
"normal",
"eco"
]
}
}Properties in the full example:
| Property | Required? | Meaning / default |
|---|---|---|
id |
Required | Stable application key; unique across registered pages. |
type |
Required | Enabled field type. |
name |
Required title¹ | Display title; may be replaced by a nonempty names object. |
default |
Optional | Omit to use the built-in initial value. |
controls |
Optional | Omit to use the preset controls; supplying an array replaces them. |
ha |
Optional | Omit to use automatic HA discovery; supplied properties override defaults. |
¹ name can be replaced by names. Other shared optional properties are listed in the catalogue.
The control uses a circular humidity dial (0–100%, step 1), power toggle and mode selector. Its modes use rounded buttons like Climate, with the current mode also shown inside the dial. Its active arc uses solid dark blue while on and gray while off. Its default state is included in the definition below.
The preset modes are normal and eco. Power uses base-topic ON/OFF, target
humidity uses _humidity, and mode uses _mode. Publish a complete value from
code when reporting measured humidity. To change the humidity range or mode
list, replace the appropriate controls entries and matching ha properties;
top-level climate modes/fan_modes do not configure this descriptor.
MQTT component: humidifier. Requires the control’s feature flag, dynamic pages, MQTT and HA support to be enabled. ArdPortal registers MQTT Discovery and routes state/commands; the sketch implements device behavior. Action callbacks acknowledge acceptance, not physical completion.
Supported by ArdPortal: On/off, target humidity 0–100, reported current humidity and mode selection (normal/eco in the preset). Separate target/mode command topics and state templates are provided.
Not provided by the built-in integration / limits: No humidity-control algorithm, humidity sensor driver or automatic dehumidifier mapping. Additional modes require matching controls and ha.modes, not only an advertised HA list.
Explicit ha properties can override Discovery metadata. They do not create additional hardware behavior, application value properties or command handlers by themselves. See HA integration for the shared setup.
Implemented as a composite mapping. The functions below are separate standard endpoints on the same physical Zigbee device. The optional generated Zigbee2MQTT converter and ZHA quirk add names and option/state semantics; a composite mapping does not guarantee one combined gateway entity. Requires ESP32-C5/C6/H2, Zigbee and dynamic pages enabled, and the field’s control flag enabled. MQTT/HA is not required.
Standard mapping: On/Off + Analog Output + Multistate Output + Relative Humidity Measurement.
Supported by ArdPortal: Power, target humidity (0–100%), mode (1=normal, 2=eco in the preset), and measured current humidity are separate endpoints.
Not provided / limits: No native unified humidifier entity, humidity-control algorithm or Dehumidification Control mapping. Mode names are not sent as StateText; generic mode/target controls may not appear in some gateways.
Endpoint IDs follow registration order, then the preset’s controls order; read-only measurement/status endpoints follow the editable/action endpoints. Composite fields consume multiple slots in the shared 239-endpoint budget. Startup stages one endpoint per loop and reports one endpoint per loop. Values and action callbacks use the existing AppConfig routes and persist; accepting an action is not hardware completion.
Standard Basic ProductLabel contains field name / property or action, truncated to 63 UTF-8 bytes; Analog/Multistate endpoints also carry their Description. A gateway is not required to use these labels or expose all these clusters. Option/state names are documented here but are not currently sent as StateText. Unknown discrete readings set the standard status fault flag and leave the last representable ordinal unchanged.
visibleWhen does not remove endpoints or create a dynamic Zigbee form. Dependency rules do not affect Zigbee control visibility or command acceptance. Native endpoint definitions freeze at startup; changes need restart. Physical coordinator interoperability is still unverified.
See Zigbee integration and page/order limitations.
These examples use the field ID from the JSON above and an existing ArdPortal portal. Run them after page registration has finished and portal.portalAndAppConfigReady() is true. Call portal.loop() frequently. Register callbacks once in setup(); do not repeat setters on every loop iteration.
Set "persist": true on this field in its page JSON. It is optional for editable fields whose preset already persists settings, but required to override a RAM-only preset such as a sensor. Calling setAppConfigValue() sets the control value and ArdPortal automatically saves AppConfig through its integrated ArdFS storage. Do not create an ArdFS object or call a separate write/flush method. The automatic save is coalesced and advanced by subsequent portal.loop() calls.
// Use this path when the value is a setting that should survive restart.
ArdJSON::JSONVar next = ArdJSON::JSON.parse(R"JSON({"state":"OFF","humidity":50,"current_humidity":null,"mode":"normal"})JSON");
if (!next.isValid() || !portal.setAppConfigValue("humidifier", next)) {
Serial.println("Setting rejected or storage temporarily unavailable");
}true from the setter means acceptance, not a completed flash write. Configure this callback once to observe the result:
portal.onPortalAndAppConfigSaved([](bool ok, const String& error) {
if (!ok) Serial.println(error);
});// Use this alternative for live readings/status; never writes ArdFS.
ArdJSON::JSONVar next = ArdJSON::JSON.parse(R"JSON({"state":"OFF","humidity":50,"current_humidity":null,"mode":"normal"})JSON");
if (!next.isValid() || !portal.setAppConfigStateValue("humidifier", next, false)) {
Serial.println("Runtime value rejected");
}The third argument false avoids queuing an immediate MQTT publication. Use true or omit it to queue changed state. RAM updates work regardless of persist. Alternatively, with "persist": false, setAppConfigValue() also follows the RAM-only path.
const ArdJSON::JSONVar current = portal.getAppConfigValue("humidifier");
if (!current.isUndefined() && current.isValid()) {
Serial.println(ArdJSON::JSON.stringify(current));
}The getter returns the effective field value: RAM override first, then saved AppConfig, then the definition default. A RAM-only update is lost on restart; the saved value/default becomes effective again. Choose the persistent or RAM path for a given value. A RAM override can mask a later persistent change for the same ID; there is no API to clear just that override. Prefer separate setting and telemetry IDs when both are needed.
ArdPortal · ArdFS · ArdJSON — Source · Releases · MIT license