VMware vCenter

Discovers VMs, ESXi hosts and datastores, and — unusually — monitors them too, through the vCenter server rather than through the guest.


Configuration

Field Default
Host — vCenter address
Port 443
Verify TLS on
Username —
Password — secret
Auto-Discovery Interval 12 hours 1–24
VM Filter — an Include or Exclude list (one mode at a time), wildcards against the VM name (vmInclude / vmExclude)
Verbose logging off

The Monitoring tab carries the rest:

Control Default
Verify presence on the post-sync presence pass
Virtual Machines block — the full workstation/server-style block: agent deploy + interface/storage auto-monitor
ESXi Hosts block — the reduced block: addAsMonitored + streams only

Supported: vCenter 7.0 U2 and later.

A read-only vCenter account is enough — Polaris never writes to vCenter — but it needs inventory read. A post-login 401 on the inventory calls is the signature of a missing inventory permission rather than a bad password.

Transport: vSphere Automation REST for session auth and most reads, plus two narrow SOAP property-collector calls for what REST cannot provide — batched VM quick-stats, and datastore backing / host-mount information.


What it discovers

Object Becomes
Virtual machine an Asset of type server
ESXi host an Asset of type hypervisor
Datastore a current-state row, delete-replaced per run, with array-vendor identification from the NAA prefix

VMs are typed server. VM identity lives in the asset's virtualization blob and its vcenter-vm source row. That matters because the VM-class behaviours — the dependency-layer stamp, the monitored sweep — gate on ownership (discoveredByIntegrationId), not on the type, so vCenter never fights a directory integration over a MAC-matched server it merely enriches.

Hosts sync first, so each VM's virtualization blob can link its host asset.

The VM match cascade

vcenter-vm source row by external id (instance UUID, then moref)
  → vNIC MAC — a positive-identity takeover of a directory- or
    Fortinet-discovered asset
    → hostname collision → Conflict
      → create

Guest filesystems

The vcenter storage stream samples each VM's guest filesystems every system-info pass, so they appear in the System tab's Storage table with history, pinning and alerting.


Monitoring through vCenter

The vcenter polling method covers four streams — responseTime, cpuMemory, interfaces and storage — and is the source default for all four, on both VMs and ESXi hosts.

That is what lets a vCenter fleet be monitored with no credential in the guest, no SNMP enabled on ESXi, and no reachable guest IP.

Two warm caches back it, each one SOAP round trip per integration per tick:

Cache Serves
VM quick-stats CPU, RAM, the memory breakdown, power state, uptime, guest disk, guest net
Host snapshot CPU, RAM, connection state, uptime, pNICs, VMkernel ports, virtual switches — paired with the datastore inventory in one session

The host snapshot is the same fetch discovery uses, and its two halves report failure separately, so a host-property gap cannot cost discovery its datastore detail.

Per-core CPU and the memory breakdown

A vCenter-monitored VM or ESXi host is charted the way an agent-monitored host is: Assets → System splits CPU & Memory into two charts, a per-core CPU chart and a byte-scaled memory stack, under one range selector.

CPU chart Memory chart, against
VM one line per vCPU configured RAM — private, shared, ballooned, host-swapped, compressed
ESXi host one line per physical core installed RAM — consumed, ballooned, host-swapped

The gap between the stack and the dashed Installed total line is memory nothing has had to touch.

These bands are the hypervisor's accounting, not the guest's, and the legend says so. They answer a question no agent inside the VM can: ballooned is memory the balloon driver has handed back to the host, host-swapped is guest memory ESXi has paged out to disk, and compressed is guest memory it has squeezed rather than paged. All three climbing is a host under memory pressure taking memory away from this guest — from inside the guest that is invisible, and its own free-memory figure will not move.

They are also why the agent's bands and these are never mixed in one chart. Processes / buffers / cache and private / shared / ballooned are two different measurements of the same RAM, and stacking them together would be arithmetic about nothing.

Two things that make cores go missing

  • Per-core detail is kept for the detail-retention window only (7 days by default — Server Settings → Retention). A longer range is served from hourly/daily rollups, which keep the cross-core average alone; the chart says so when that is why.
  • The account needs the Performance privilege. Per-core CPU and a host's balloon/swap come from vCenter's PerformanceManager, not from the quick-stats properties everything else here uses. A read-only service account that lacks it still yields full CPU, memory, power state and interfaces — the charts simply fall back to the aggregate line, exactly as they do for SNMP. Nothing fails, and nothing says so louder than a missing legend; check the privilege if an ESXi host charts one CPU line where you expect its cores.

Absent is not unreachable

vCenter answering without this asset in it is a real finding and fails the probe. Polaris being unable to ask returns a skip — no sample, no counter, cadence anchor only.

So a vCenter outage can never declare an entire virtual fleet down at once.

Nested host interfaces

An ESXi host's interfaces arrive nested. Each vSwitch — standard, or the host's end of a distributed switch — is written as an aggregate row, with its uplink pNICs and the VMkernel ports riding its port groups stamped as its children. That is the FortiSwitch-trunk shape, so the System tab nests it unchanged. Each VMkernel port picks up its port group's VLAN id.

A vSwitch's operational status is derived — up while any uplink is up, and null with no uplinks at all, because an internal-only vSwitch is not an outage. It carries no speed, vCenter publishing no aggregate rate.

Teaming policy, port counts and the port-group VLAN table are inventory and render on the host's General tab instead.

Where a host's datastores and VMs appear

An ESXi host's datastores are on its System tab's Storage table, one row per mounted datastore. That is where they have history, pinning and alerting. Each row also shows the datastore's type, backing array and provisioned size, and is flagged (inaccessible) when vCenter reports it so. The VMs placed on the host are on a Virtual Machines tab of their own. Neither appears on the General tab. A host that is not monitored has no System tab content, so its datastores are not shown until monitoring is turned on.

Temperature and LLDP are unavailable on this method. The dedicated storage-only cadence stays SNMP-only, because vCenter storage already rides the system-info pass.


Dependency edges

VM→host placement writes dependency edges, and they are vMotion-safe: a VM on a clustered host gets one edge per cluster-member host, so all-down suppression fires only when the entire cluster is dark.

See Dependency suppression.


The disappearance sweep

vCenter's fleet-absence rule is worth knowing precisely — the AD and Entra sweep is opt-in and judged differently (by which integration manages the asset rather than by whether anything still claims it), so do not read one as the other. See Integration-Directory.

A VM or ESXi host that leaves the inventory is decommissioned only if nothing else claims it.

The last pass deletes the stale vcenter-vm / vcenter-host source rows. An asset thereby left with no AssetSource row at all is flipped to decommissioned (with any open maintenance window force-closed first). Any surviving source — a directory record, an Arc row, a reporting agent, the manual row of an operator-created asset — leaves the asset untouched.

Absence only counts when the read was whole

The pass is skipped entirely, deletes included, when the inventory is:

  • incomplete — a per-host VM list failed (those are logged rather than failing the run), or
  • empty.

And VMs still present in the raw pre-filter listing are retained — so changing vmInclude or vmExclude decommissions nothing.

A scoped run suppresses the sweep with a second, independent guard, along with the dependency-edge and datastore delete-replaces.


Merged assets keep their own identity

When vCenter matches a VM to an asset a directory already discovered, the merge is an enrichment, not a takeover:

  • the asset keeps its directory asset type — it flips only from the other catch-all;
  • it keeps its discoveredByIntegrationId;
  • the vcenter-vm source row is how the monitor collectors find the vCenter integration for it.

Resolution for monitoring goes through the vcenter-vm or vcenter-host source row, not through discoveredByIntegration — which is also why the vcenter polling method is allowed on the directory source kinds.


Troubleshooting

Symptom Look at
401 after a successful login the account is missing inventory permission, not the wrong password
Every VM went down at once that should be a skip, not a miss — check whether Polaris can reach vCenter at all
A VM was decommissioned that still exists it left the inventory and had no other source. Check for a filter change (which should retain it) and for an incomplete read
VMs vanished after editing vmInclude they should not — the pre-filter retention exists for exactly this. Check the run's Events
No storage history on VMs the vcenter storage stream is the source, not discovery
Datastore capacity looks stale it is a delete-replace per run — check whether the host-snapshot half of the paired fetch failed