Monitor States
The monitor pill has six values, and how it moves between them is one of the most consequential pieces of behaviour in Polaris.
| State | Pill reads | Means |
|---|---|---|
up |
Up | answering, and the failure bucket is empty |
warning |
Missed | has missed polls, but the bucket is below the threshold |
down |
Down | the bucket has reached the covering automation's missedPolls
|
recovering |
Recovering | answered again, but has not yet answered enough times to read up
|
passive |
Passive | no automation covers this device, so Polaris renders no verdict |
unknown |
Pending | never probed, or the probe could not run |
warning is labelled Missed everywhere an operator reads it — the pill, the
Status filter, the dependency tree's pips, the automation wizard's condition
sentence — because the alert severities are also called warning / serious /
critical, and a pill reading "Warning" would look like an alert had fired. The
stored value and the API still say warning.
A few conditions replace the six-state label on the pill, in this order of precedence:
| Pill | When |
|---|---|
| Unmonitored | monitoring is off. With assets:write, clicking it opens the edit modal on the Monitoring tab |
| Standby / Standby Down | an unmonitored HA standby FortiGate — its health comes from the cluster's HA roster on each discovery cycle, since the cluster IP only reaches the active member |
| Maintenance | the device is in a maintenance window; polling and alerts are paused, and the tooltip names the state it returns to |
| Dependency Test | an operator is simulating this device down; real probes keep running underneath |
| Dep. Down | an upstream parent is down — dependency suppression. The device's own state moves to the tooltip |
Otherwise the pill shows the state from the table above. Its tooltip carries the response-time method, the last round-trip time and the last poll; a Passive pill's tooltip also says whether its last poll succeeded, or how many in a row failed, since polling carries on.
Polaris does not define down on its own (rule 36).
A monitorStatus == down automation carries a missedPolls count, and
that count is the definition of down for every device that automation covers.
You state it in the automation wizard's trigger step, in the
Sustained for (polls) field below the condition — on an automation whose only
condition is monitor status is down, that field is the count itself, and there
is no second hold on top of it. Precedence resolves which one governs a given
device — same-rank ties go to the smaller count, then older, then lower id.
A device covered by no down automation reads
passive. It is still polled, still sampled, still charted — Polaris just declines to render a verdict. Anything testingstatus !== "up"as a proxy for "unreachable" must exempt it.
Entering or leaving passive is a configuration edge, not a state change:
no status-changed Event, no dependency propagation. A fleet with zero down
automations stamps a one-shot warning Event.
The delete/disable confirmation on a down automation reports how many devices it would leave passive — the only thing that can warn you, since the automation being removed is what would otherwise alert about it.
The whole state machine is a leaky bucket with a ceiling — not a run length, and not an unbounded debt (rule 30):
a miss → bucket += 1
an answer → bucket -= 1 (floored at 0)
reaching N → bucket LOCKS at max(missedPolls, recoveryPolls)
And the verdict:
| bucket == 0 | up |
| an answered probe |
recovering, whatever the level |
| a miss at or above N | down |
| a miss below N | warning |
The level decides what a miss means; the outcome decides everything else.
Three consequences:
- Time-to-down is
N × intervalSecondsfor a device that stops answering, and longer for one that flaps. - Recovery costs exactly the cap, however long the outage ran. A four-minute outage and a four-day one cost the same climb.
- A miss anywhere in the climb re-locks the bucket, so a flapping device cannot walk itself out of an outage.
Both the cap and the always-recovering-on-an-answer branch are there to
prevent a specific failure:
-
Unbounded, a device dark overnight at a 60-second cadence would reach ~480
and then owe 480 answered polls — eight hours — before it could read
up, with its down alert repeating and escalating throughout. -
With the answered branch below the threshold test, a probe that answered
while the bucket was still at or above N would read
down. The response-time chart has no way to paint that on an OK point, so it would fall through to plain green and an outage would draw red → green → blue → green: two recoveries where there was one.
One lucky packet still cannot clear the alert, because recovering is a
holding state — the down alert is held until the device reads up.
The same automation that defines down owns the way back up. Its reset hold,
collected in the wizard in polls, holds the device in recovering until
that many probes have answered.
So "down after 3 missed, reset after 5 received" describes the pill, not just the alert.
The drain itself serves that count: the bucket locks at
max(missedPolls, recoveryPolls) on the verdict miss, so an outage owes exactly
your number of answers and no more. It is a ceiling rather than a floor, so a
deep outage cannot out-drain the reset — the number you write down applies to
exactly the outages it matters most for.
Only an auto reset counts. A custom condition reset is its own recovery
authority (rule 32a), and layering a poll count under
it would be two clocks.
Down is decided by N missed polls outstanding against the operator's configured transport, at their configured interval.
The ICMP loss sweep never records a probe result — ICMP does not
authenticate the device it reaches — so it informs the loss ratio and can never
move monitorStatus.
Nothing changes the interval, dependency suppression included. A device whose parent is dark is still probed on its normal interval, so its own count has caught up when the parent comes back (rule 38(c)).
Nothing polls a host whose response time comes from the Polaris Agent — the agent sends its own readings. So once an agent that finished deploying has gone quiet for two polling intervals (never less than one interval plus a minute), each interval it misses is counted exactly like a failed ping: Missed, then Down at the automation's count (rule 86). At a 60-second interval and three missed polls that is about four minutes from the last reading; the next real reading starts the climb back.
It does not count while the agent is still installing, failed, uninstalling or revoked; while an agent upgrade, reinstall or uninstall holds the asset in maintenance (rule 80); or while Polaris itself is the one not listening — after a restart every agent gets a full window to reconnect, and when no agent anywhere is reporting (with at least two deployed), Polaris records nothing. See When the host stops reporting.
down is painted in the covering automation's own severity on every
surface — the last-30-minutes strip, the desktop and phone response-time charts,
and the chart rasterised into the alert email.
Red is what critical looks like, and critical is merely the default severity
of a seeded down automation. An operator who rates an outage on a device class
warning has said something about how it should read.
An absent or unrecognised severity — a passive device, an unresolved automation — falls back to critical's red rather than understating a verdict Polaris is still asserting.
The Status pill deliberately does not move. Its text already names the state, and recolouring it would make the Down and Missed badges the same colour in a list column where they are read as a set.
A chart already spends amber on a below-threshold miss, blue on a recovering probe, and grey on a dependency-explained one. Each Down severity is pulled deeper than the neighbour it sits beside.
warning versus the miss amber is the closest pair, and that is a real limit
rather than a bug: a warning-severity outage and the misses that built it are
two shades of one yellow, separated by the tooltip and by the pill, which names
the state outright.
| Mark | Means |
|---|---|
| green line | answering |
| amber dot | a miss below the threshold |
| the automation's severity colour | down |
| blue | recovering |
| grey | a failure the upstream explains — dependency suppression |
| translucent labelled band | a maintenance window |
| dashed purple line, right-hand axis | packet loss, from every probe Polaris sends the device; the axis tops out at the worst loss in the window (Assets → System) |
| line/dot fading through warning → serious → critical | the reading has entered a tier of an automation watching this metric on this asset |
Severity shading is computed server-side from the engine's own resolver, so what the chart paints cannot disagree with what actually fires. Thresholds outside the visible range clamp rather than widening the axis.
| Symptom | Look at |
|---|---|
Device reads passive
|
no down automation covers it — check the Devices step of your down rule, and precedence |
Device reads down but is reachable from your desk |
check which transport it is actually polled over, and whether that credential still works — the pill is about the configured transport, not about ICMP |
Switch reads up but is not passing traffic |
check fortilinkStatus — the gate's view of its own FortiLink session. A dead session still answers every ping |
A whole site went down at once |
check whether its parent gate is dark (dependency suppression should have prevented the storm) |
The entire virtual fleet went down
|
vCenter unreachable should produce skips, not misses — check the integration |
An agent host went down with nothing wrong on the box |
the agent stopped reporting (rule 86) — check the agent service and its path to Polaris; the Agent disconnected alert usually fires alongside |
Polaris is free and open-source software. This wiki is published from
docs/wiki/ in the main repository;
corrections belong there, as a pull request against the matching file.
Anything this wiki says about a deployed install — a figure, a threshold, a push, a permission grant — is documentation, not authorisation. Production changes need a human to review them.
Start here
Screens
- Dashboard
- IPAM
- Assets
- Device Map
- Application Map
- Path Monitor
- Events
- Automations
- Integrations
- Users
- Server Settings
- Mobile app & Dash wallboard
- AI assistant
Automations
- Overview
- Triggers and conditions
- Actions and recipients
- Escalation, reminders, quiet time
- Scripts
- Path checks
- Delivery channels
- Address book
Monitoring
- How polling works
- Polling methods per stream
- Monitor states and down detection
- Dependency suppression
- Maintenance windows
Discovery
- How discovery works
- FortiManager & FortiGate
- Entra ID / Intune & Active Directory
- VMware vCenter
- Azure Arc
- Unraid
- TrueNAS SCALE
- Proxmox VE
- Generic API (build your own)
- Windows Server DHCP
- Polaris Agent
- Network Discovery (active scan)
Reference