Monitor States

David Moore edited this page Oct 9, 2026 · 5 revisions

Monitor states and down detection

The monitor pill has six values, and how it moves between them is one of the most consequential pieces of behaviour in Polaris.

State Pill reads Means
up Up answering, and the failure bucket is empty
warning Missed has missed polls, but the bucket is below the threshold
down Down the bucket has reached the covering automation's missedPolls
recovering Recovering answered again, but has not yet answered enough times to read up
passive Passive no automation covers this device, so Polaris renders no verdict
unknown Pending never probed, or the probe could not run

warning is labelled Missed everywhere an operator reads it — the pill, the Status filter, the dependency tree's pips, the automation wizard's condition sentence — because the alert severities are also called warning / serious / critical, and a pill reading "Warning" would look like an alert had fired. The stored value and the API still say warning.


What the pill says

A few conditions replace the six-state label on the pill, in this order of precedence:

Pill When
Unmonitored monitoring is off. With assets:write, clicking it opens the edit modal on the Monitoring tab
Standby / Standby Down an unmonitored HA standby FortiGate — its health comes from the cluster's HA roster on each discovery cycle, since the cluster IP only reaches the active member
Maintenance the device is in a maintenance window; polling and alerts are paused, and the tooltip names the state it returns to
Dependency Test an operator is simulating this device down; real probes keep running underneath
Dep. Down an upstream parent is down — dependency suppression. The device's own state moves to the tooltip

Otherwise the pill shows the state from the table above. Its tooltip carries the response-time method, the last round-trip time and the last poll; a Passive pill's tooltip also says whether its last poll succeeded, or how many in a row failed, since polling carries on.


The automation decides what "down" means

Polaris does not define down on its own (rule 36).

A monitorStatus == down automation carries a missedPolls count, and that count is the definition of down for every device that automation covers. You state it in the automation wizard's trigger step, in the Sustained for (polls) field below the condition — on an automation whose only condition is monitor status is down, that field is the count itself, and there is no second hold on top of it. Precedence resolves which one governs a given device — same-rank ties go to the smaller count, then older, then lower id.

A device covered by no down automation reads passive. It is still polled, still sampled, still charted — Polaris just declines to render a verdict. Anything testing status !== "up" as a proxy for "unreachable" must exempt it.

Entering or leaving passive is a configuration edge, not a state change: no status-changed Event, no dependency propagation. A fleet with zero down automations stamps a one-shot warning Event.

The delete/disable confirmation on a down automation reports how many devices it would leave passive — the only thing that can warn you, since the automation being removed is what would otherwise alert about it.


The failure bucket

The whole state machine is a leaky bucket with a ceiling — not a run length, and not an unbounded debt (rule 30):

a miss        → bucket += 1
an answer     → bucket -= 1   (floored at 0)
reaching N    → bucket LOCKS at max(missedPolls, recoveryPolls)

And the verdict:

bucket == 0 up
an answered probe recovering, whatever the level
a miss at or above N down
a miss below N warning

The level decides what a miss means; the outcome decides everything else.

Three consequences:

  • Time-to-down is N × intervalSeconds for a device that stops answering, and longer for one that flaps.
  • Recovery costs exactly the cap, however long the outage ran. A four-minute outage and a four-day one cost the same climb.
  • A miss anywhere in the climb re-locks the bucket, so a flapping device cannot walk itself out of an outage.

Why the ceiling exists

Both the cap and the always-recovering-on-an-answer branch are there to prevent a specific failure:

  • Unbounded, a device dark overnight at a 60-second cadence would reach ~480 and then owe 480 answered polls — eight hours — before it could read up, with its down alert repeating and escalating throughout.
  • With the answered branch below the threshold test, a probe that answered while the bucket was still at or above N would read down. The response-time chart has no way to paint that on an OK point, so it would fall through to plain green and an outage would draw red → green → blue → green: two recoveries where there was one.

One lucky packet still cannot clear the alert, because recovering is a holding state — the down alert is held until the device reads up.


Recovery

The same automation that defines down owns the way back up. Its reset hold, collected in the wizard in polls, holds the device in recovering until that many probes have answered.

So "down after 3 missed, reset after 5 received" describes the pill, not just the alert.

The drain itself serves that count: the bucket locks at max(missedPolls, recoveryPolls) on the verdict miss, so an outage owes exactly your number of answers and no more. It is a ceiling rather than a floor, so a deep outage cannot out-drain the reset — the number you write down applies to exactly the outages it matters most for.

Only an auto reset counts. A custom condition reset is its own recovery authority (rule 32a), and layering a poll count under it would be two clocks.


Confirmation is the configured cadence's job

Down is decided by N missed polls outstanding against the operator's configured transport, at their configured interval.

The ICMP loss sweep never records a probe result — ICMP does not authenticate the device it reaches — so it informs the loss ratio and can never move monitorStatus.

Nothing changes the interval, dependency suppression included. A device whose parent is dark is still probed on its normal interval, so its own count has caught up when the parent comes back (rule 38(c)).

An agent host's silence is a miss

Nothing polls a host whose response time comes from the Polaris Agent — the agent sends its own readings. So once an agent that finished deploying has gone quiet for two polling intervals (never less than one interval plus a minute), each interval it misses is counted exactly like a failed ping: Missed, then Down at the automation's count (rule 86). At a 60-second interval and three missed polls that is about four minutes from the last reading; the next real reading starts the climb back.

It does not count while the agent is still installing, failed, uninstalling or revoked; while an agent upgrade, reinstall or uninstall holds the asset in maintenance (rule 80); or while Polaris itself is the one not listening — after a restart every agent gets a full window to reconnect, and when no agent anywhere is reporting (with at least two deployed), Polaris records nothing. See When the host stops reporting.


The colour of Down is not red

down is painted in the covering automation's own severity on every surface — the last-30-minutes strip, the desktop and phone response-time charts, and the chart rasterised into the alert email.

Red is what critical looks like, and critical is merely the default severity of a seeded down automation. An operator who rates an outage on a device class warning has said something about how it should read.

An absent or unrecognised severity — a passive device, an unresolved automation — falls back to critical's red rather than understating a verdict Polaris is still asserting.

The Status pill deliberately does not move. Its text already names the state, and recolouring it would make the Down and Missed badges the same colour in a list column where they are read as a set.

The chart palette

A chart already spends amber on a below-threshold miss, blue on a recovering probe, and grey on a dependency-explained one. Each Down severity is pulled deeper than the neighbour it sits beside.

warning versus the miss amber is the closest pair, and that is a real limit rather than a bug: a warning-severity outage and the misses that built it are two shades of one yellow, separated by the tooltip and by the pill, which names the state outright.


Reading a response-time chart

Mark Means
green line answering
amber dot a miss below the threshold
the automation's severity colour down
blue recovering
grey a failure the upstream explains — dependency suppression
translucent labelled band a maintenance window
dashed purple line, right-hand axis packet loss, from every probe Polaris sends the device; the axis tops out at the worst loss in the window (Assets → System)
line/dot fading through warning → serious → critical the reading has entered a tier of an automation watching this metric on this asset

Severity shading is computed server-side from the engine's own resolver, so what the chart paints cannot disagree with what actually fires. Thresholds outside the visible range clamp rather than widening the axis.


Troubleshooting a wrong pill

Symptom Look at
Device reads passive no down automation covers it — check the Devices step of your down rule, and precedence
Device reads down but is reachable from your desk check which transport it is actually polled over, and whether that credential still works — the pill is about the configured transport, not about ICMP
Switch reads up but is not passing traffic check fortilinkStatus — the gate's view of its own FortiLink session. A dead session still answers every ping
A whole site went down at once check whether its parent gate is dark (dependency suppression should have prevented the storm)
The entire virtual fleet went down vCenter unreachable should produce skips, not misses — check the integration
An agent host went down with nothing wrong on the box the agent stopped reporting (rule 86) — check the agent service and its path to Polaris; the Agent disconnected alert usually fires alongside