Skip to content

Design: Devices in a Tree

Timo Sariwating edited this page Nov 6, 2026 · 2 revisions

Status: in the store since 2026-11-04 (powered_by, power_channel, reached_through, with a check against loops); not yet on screen, and no plug drivers yet.

Devices are not a flat list. A printer hangs behind a smart plug; a power strip with a dryer and a lamp hangs behind one channel of a Shelly; one agent on a Pi serves a printer, a label printer and a bench supply. Two relations describe that, kept apart because they answer different questions.

flowchart TB
    subgraph power["Powered by (energy)"]
        W["Wall plug<br/>Shelly Plus 1PM"] -->|"ch 0"| S["Power strip<br/>Tasmota, 4 ch"]
        S -->|"ch 1"| D["Filament dryer"]
        S -->|"ch 1"| L["Lamp"]
        S -->|"ch 2"| F["Fume extractor"]
        P2["Shelly Plus 2PM"] -->|"ch 0"| M["MK3S"]
        P2 -->|"ch 1"| O["Ortur laser"]
    end
    subgraph data["Reached through (data)"]
        A["Agent on a Pi"] --- M2["MK3S"]
        A --- DY["DYMO"]
        A --- R["Riden RD6006W"]
        B["MQTT broker"] --- P3["Shellies"]
    end
Loading

1. Powered by

A device hangs behind a channel of another device that switches or measures power: a Shelly Plus 2PM has two channels, a Tasmota power strip four.

  • Several devices can share one channel (everything on a power strip).
  • The tree can go deeper (a strip behind a wall plug). The hub refuses a loop, and a parent outside the space.
  • A plug, a power meter or a bench supply is a device like any other, of its own kind (power, supply), with its own page.

What it gives:

  • The right state. A device whose plug is off shows off at the plug, not disconnected; its page offers to switch the plug on.
  • Safe switching. Off is refused while something behind the plug is busy or still hot (a printer's bed or nozzle above 50 °C), unless forced, and always confirmed.
  • Energy. The plug's power and energy are shown with the devices behind it and counted per job (kWh per print, per laser job).
  • Rules build on it: the fume extractor on while the laser runs and two minutes after; the dryer on before a planned print; a printer off once done and cooled; the laser's power cut when its flame sensor fires.

2. Reached through

The agent or broker a device talks to the hub through.

  • Today one agent drives one machine, with one token. Next, one agent registers each machine it serves as a device of its own under itself, over one connection: a Pi with a printer, a DYMO and a bench supply.
  • A Shelly reached through an MQTT broker sits under that broker the same way; the broker (or a bridge in the hub) is the device it is reached through.
  • When an agent goes offline, everything under it is unreachable, not each disconnected on its own: one cause, shown once.

In the store

Column What
machines.powered_by The device id of the plug (or strip, or meter)
machines.power_channel Its channel, from 0
machines.reached_through The device id of the agent or broker

All optional. set_powered_by walks up from the new parent and refuses when it meets the device itself (tested: wall plug → strip → dryer and lamp, and the loops refused).

Next

  1. Plug drivers: Shelly Gen2+ (RPC over HTTP and WebSocket, MQTT) and Tasmota (MQTT, HTTP), through the agent or a broker.
  2. Settings: Powered by (a plug and a channel), on every device's page.
  3. The plug's state on the devices behind it, switching from their pages, the safety rules.
  4. An agent with several devices (a protocol change: devices under one agent token).

Clone this wiki locally