Status: idea (2026-11-19). Hardware ordered, nothing built yet.
A general door controller: our own firmware on a small relay board that opens locks and reports whether they are shut. Its first use is a locker function: a few small cabinet doors, each with its own lock. Later the same firmware can drive other doors.
The firmware is our own, written for Maker Connect. Deliberately not ESPHome or Tasmota. This changes the first plan in Door Access, where Home Assistant drove the hardware.
Lockers and doors are access (getting in), not machine permissions (who may use which machine). See Door Access.
An ESP32 board with relays and inputs, ordered 2026-11-19 and not yet arrived. Its exact relay and input ratings are checked when it is in hand.
Plan: one relay per lock (opens it), one input per lock (reads its switch).
Electronic lock with feedback, metal, 12 V DC. We have 4.
Shop: Tinytronics: Electronic lock with feedback, metal, 12V DC
How it works:
- Opening: 12 V on the red and black wires (polarity does not matter). The solenoid releases the hook, which springs out.
- Feedback: when the lock is closed, the blue and white wires are connected by an internal switch (normally open). Open lock = open circuit.
| Property | Value |
|---|---|
| Model | SARY XG-07C-12V |
| Supply | 12 V DC (min and max) |
| Current while opening | about 2000 mA (±10 % at 12 V) |
| Longest activation | 0.5 s |
| Cooldown after each activation | at least 10 s |
| Feedback switch | physical, NO, closed when locked; lifespan 300,000 |
| Size | 73 × 58 × 13 mm, 148 g |
| Mounting | M4 thread |
| Connectors | power: JST-SM (compatible) male; switch: JST-SM (compatible) female |
| Wires | 0.15 m |
| Operating range | −20 to 40 °C, 5–90 % RH |
| In the box | the lock and its hook |
These come from the lock's datasheet. A longer pulse burns out the coil.
- Opening is a pulse of at most 0.5 s. The firmware enforces this itself. No setting, command or bug may hold a relay on longer.
- At least 10 s between two pulses of the same lock. An open request inside that time waits or is refused with a reason. It is never sent through.
- The switch is the truth. "Locked" means the blue/white circuit is closed. After a pulse the firmware reports what the switch says, not what it asked for.
- At about 2 A per lock, the power supply must cover every lock that can be pulsed at the same time.
- Who may open which locker, and how: a badge, the website, or both?
- What does the controller do when the hub cannot be reached?
- How does the controller talk to the hub: like the agent, or its own link?
- How many locks may pulse at once, and so how big is the power supply?
Home · maker-connect.xyz · for makerspaces
Guides
- Getting Started
- Proxmox
- The Agent
- Updates
- Klipper
- Lasers
- Label Printers
- Cameras
- Materials
- Machine Profiles
- Supported Machines
- Hardware
- Similar Projects
Design
- House Style
- Hub Core v2
- Devices in a Tree
- Multi-Tenant Hub
- Consumables and Stock
- Print Farm
- Door Access
- Door Controller
- The Website
- Guides
- Stream Deck (idea, WIP)
- Roadmap
Code