Feed override lets a host speed up or slow down the feed rate of a running job, from 5% to 200%, without stopping it. It is available from firmware build 450.05.

The settings use the same names as g2core, so a host that already drives g2core's feed override can send the same commands.

The settings

Token Access Meaning Default
mfo read/write Requested feed factor, 0.05 to 2.0 1.0
mfoe read/write Operator feed override enable, 0 or 1 1
m48e read/write Operator master override enable, 0 or 1 1
mfc read only Feed factor currently in effect 1.0
mcp read only 1 if axis or motor speed limits capped the accepted speed 0
mfe read only Effective permission: 1 only if m48e, mfoe and the program all allow override 1

Set them like any other setting: {"mfo":0.5} in JSON or $mfo=0.5 in text mode asks for 50%. Read them with {"mfo":null} or $mfo.

These values are never saved to EEPROM. Because of that they are accepted while a job runs, unlike saved settings, which are refused with status 117 during a job (see Changing settings while a job runs). $defa does not change them, and they are not part of a settings backup.

  • A factor outside 0.05 to 2.0, or an enable other than 0 or 1, is refused with status 110 and changes nothing.
  • Writing a read-only token (mfc, mcp, mfe) is refused with status 104.
  • mfo, mfc, mcp and mfe can be added to the status report list.

When a change takes effect

The reply to {"mfo":0.5} confirms that the request was accepted. The machine changes speed at the next point in the planned path where it can reach the new speed smoothly, within its acceleration and jerk limits; mfc changes to the new factor at that moment. If no remaining part of the queued path can take the change, the request waits until one can.

The factor applies to feed moves: G1, G2 and G3 in units-per-minute mode (G94), long or short, including moves that are already queued in the planner. A change is blended into the queued path, so the whole remaining job runs as if every F word had been scaled by the factor. On a test machine running a 600 mm/min job, a change to 50% started slowing the axis about 0.4 s after the request and reached the new speed within about 0.8 s, with no overshoot. Rapids (G0), inverse-time moves (G93), homing, probing and jogging are not affected.

Build 450.05 was more limited: there the factor took effect only in the constant-speed part of a long straight G1 move, each new move restarted at its programmed feed, and arcs and short moves were not slowed. Update to 450.06 or later if you depend on override for jobs made of short moves or arcs.

The factor scales the programmed feed rate. Axis and motor speed limits, acceleration and jerk still apply, so 200% does not promise twice the speed; mcp reports when a limit capped it. Read vel in a status report for the actual speed.

During a feedhold a new factor is accepted and used after resume. Changing the factor never resumes motion by itself.

Permission: operator and program

Three switches must all allow override:

  • m48e and mfoe, set by the host (the operator);
  • the program's own permission, set by G-code in queue order: M48 enables, M49 disables, M50 (or M50 P1) enables and M50 P0 disables. Other P values are refused with status 161.

Writing m48e or mfoe to 1 cannot override an M49 in the program. Changing permission keeps the requested factor. M48 and M49 switch spindle override on and off as well; M51 controls spindle override alone (see below).

Spindle speed override

From build 450.06 the spindle speed can be overridden the same way, from 5% to 200%, with g2core's names.

Token Access Meaning Default
sso read/write Requested spindle speed factor, 0.05 to 2.0 1.0
ssoe read/write Operator spindle override enable, 0 or 1 1
ssc read only Spindle factor currently in effect 1.0
scp read only 1 if the spindle speed range capped the result 0
sse read only Effective permission: 1 only if m48e, ssoe and the program all allow it 1

Like the feed values these are never saved, so they are accepted while a job runs; out-of-range values return status 110.

  • While the spindle is on (M3 or M4) the output changes at once to S times the factor, limited to the configured spindle speed range (p1csl/p1csh for clockwise, p1wsl/p1wsh for counter-clockwise); scp reports when the range limited it. sps reads the resulting speed.
  • The factor never starts a stopped spindle. M5, an alarm, shutdown or a job kill turn the spindle off as usual, whatever the factor.
  • There is no change to motion planning: the factor only changes the spindle PWM output.
  • Program permission: M48/M49 enable and disable both feed and spindle override; M51 (or M51 P1) enables and M51 P0 disables spindle override alone, following the LinuxCNC M51 definition. They execute in queue order. Other P values are refused with status 161.
  • A board reset, a job kill (^D) and program end (M2/M30) restore the factor to 1.0, ssoe to 1 and the program permission to enabled, like the feed values. A feedhold stops motion only, so the spindle keeps running at the overridden speed during a hold.

Resets

A board reset, a job kill (^D) and program end (M2/M30, when it executes in the queue) restore the factor to 1.0, both operator switches to 1 and the program permission to enabled, following the LinuxCNC program-end rule. A queue flush (%) or feedhold keeps the operator's requested factor.

Change events

A host that wants to be told when the factor changes can enable events with {"rt":{"ov":1}} (0 turns them off). Events are sent at most once per status report interval, each on its own line without a footer:

{"ov":{"v":1,"q":4,"mfo":1.500,"mfc":1.500,"mfe":1,"capped":true}}

q is a revision number that increases with every change. {"rt":{"ov":null}} asks for one event even when events are off. Events stay enabled after a job ends, so the host sees the reset. See Runtime Session (rt) for the rt family; the older rt forms still work: {"rt":{"mfo":0.5}} is the same as {"mfo":0.5}, writing rt.mfe sets mfoe, and reading rt.mfe gives the effective permission mfe.

Compared with g2core

The names, ranges and the "not saved" behaviour match g2core, so the same host commands work on both. Differences:

  • TinyG switches override on by default (m48e and mfoe are 1); on g2core the host turns them on first.
  • TinyG keeps the program's permission (M48/M49/M50) separate from the operator switches, so an M49 in the program cannot be undone from the host.
  • A change also retimes moves already in the planner, as described above.
  • Rapid override is not implemented: there is no mto control.
  • Spindle override uses the same names as g2core (sso, ssoe) and is on by default; sse and scp are TinyG additions.

Clone this wiki locally