Notifications
You must be signed in to change notification settings - Fork 11
Stacking_multiple_carrier_boards_on_UP_Core
AAEONAEU-SW edited this page Nov 25, 2020
·
1 revision
When you stack both CRST01 and CRST02 carrier board with UP core together, please adjust the jumper on either one carrier board to make the address different with each other. If you keep default 0X50 on CRST01, please adjust the address to 0X51~0X53 on CRST02. Vice versa.
- Keep default 0X50 on CRST01, adjust CRST02.
JP3 | JP2 | Address |
---|---|---|
2-3 | 2-3 | 0X50(Default) |
2-3 | 1-2 | 0X51 |
1-2 | 2-3 | 0X52 |
1-2 | 1-2 | 0X53 |
Ex. 0X50->0X51
- Keep default 0X50 on CRST02, adjust CRST01.
JP2 | JP1 | Address |
---|---|---|
2-3 | 2-3 | 0X50(Default) |
2-3 | 1-2 | 0X51 |
1-2 | 2-3 | 0X52 |
1-2 | 1-2 | 0X53 |
Ex. 0X50->0X52
NOTE: This wiki is the main source of documentation for developers working with (or contributing to) the UP products. If this is your first time hearing about UP, we recommend starting with our main UP website, and our UP community page.