Run the Demonstration Remotely via Ethernet (AD463x)
In addition to the DataStorm DAQ development kit running in standalone hardware configuration, it can also run while connected to computer remotely via an Ethernet cable.
The AD463x demonstration uses AD4630-24® Evaluation Platform in this configuration which is comprised of the following components:
- Analog Devices EVAL-AD4630-24 (also known as EVAL-AD4630-24FMCZ) data converter board
- DataStorm DAQ (Trenz Intel Cyclone V SoC TEI0022 Development Board) (includes 12VDC power supply)
- Host Windows PC with IIO Oscilloscope and Digilent WaveForms App installed
- Ethernet Cable
- Micro USB cable
- Digilent Analog Discovery 2 Signal Generator with dual outputs
- Digilent Discovery BNC adapter board
- Two (2) BNC male to SMA Male Cable
Select the SD card as the boot source for the processor.
The FMC_VADJ power rails provide power to the EVAL-AD4630-24FMCZ via the FMC interface. This is an adjustable voltage. It must be set to 3.3V. Modify the VID_SW DIP switch settings to select 3.3V.
Follow the steps in the order shown below.
- Insert the Micro SD card into the SD card slot
- Insert the EVAL-AD4630-24FMCZ FMC connector into the FMC mating connector on the DataStorm DAQ board
- Attach PC via ethernet cable
- Attach the Micro USB cable
- Connect the Signal Generator to the EVAL-AD4630-24FMCZ SMA connectors (channel 0)
- Ensure that Jumper JP1 is at EN position as shown below
- Connect the power supply to the DataStorm DAQ
- Plug the AC-DC adapter into an AC outlet
The AD463x requires a differential signal from a signal source. The EVAL-AD4630-24FMCZ, in its default configuration, requires the input signal to be centered around VCM=2.5V (as in yellow tag #5 below). Connect the Differential signal source to IN0+/IN1+ and IN0-/IN1- inputs of EVAL-AD4630-24FMCZ.
The Analog Discovery 2 is used as a signal generator to drive the AD463x input.
Install (if not already done) the Digilent WaveForms App.
Open the WaveForms App and Click on Wavegen in the left margin which opens a waveform window
Click on Channels and select 1
Select Type as Sine
Select Frequency or Period
Set Amplitude to 1V
Set Offset to 2.5V
For Channel 2, Match the Channel 1 settings
Select the Phase to 180 degrees for Inverse signal
Click on No synchronization and select Synchronized
Click Run All
The HDL design supports the following interface and clock mode configurations:
1 Lane per channel | 2 Lane per channel | 4 Lane per channel | |
---|---|---|---|
SPI Mode | SDR | SDR | SDR |
Echo Clock Mode | SDR & DDR | SDR & DDR | SDR & DDR |
Master Clock Mode | SDR | SDR | SDR |
There are a few software components that need to be installed in order to run this demo successfully:
- IIO Oscilloscope™
- A SW terminal like Tera Term VT or Putty
IIO Oscilloscope™ is a tool developed by Analog Devices. It can be downloaded from this web site: https://github.com/analogdevicesinc/iio-oscilloscope/releases/download/v0.13-master/adi-osc-setup.exe (Download and install v0.13)
A wired ethernet point-to-point connection between the host PC and the embedded target is required. Use this link for instructions on how to assign a static IP address to the host Ethernet adapter. Set the following values
-
IP address : 192.168.0.1
-
Subnet mask : 255.255.255.0
-
No entries required for the other fields
- A wired Micro USB serial port connection between the host PC and the embedded target is required
- Launch a terminal program (like Tera Term VT or Putty) and connect using serial port
- Select 115200 baud
- Select the appropriate target COM port
Type the following at the terminal prompt to set the target IP address
- $ ifconfig eth0 192.168.0.2 up
Double click the IIO Oscilloscope application icon on the host Windows PC.
Note: IIO Oscilloscope creates a .osc_profile.ini file in the Users/UserName/Appdata/Local directory. The next time IIO Oscilloscope is opened, the existence of this file delays connection to the target. It is recommended to delete the .osc_profile.ini (if it exists) prior to launching IIO Oscilloscope.
- Select the Discoverable/Scan option and click the Refresh button..
- A successful connection results in discovery of the IIO devices. Press OK to continue.
Select a Plot Channel to be displayed in IIO Oscilloscope. Click on the check box in the Plot Channel window adjacent to voltage0. Right click on ad4630 in the Plot Channels window. Select voltage0 and rising edge as the trigger parameters.
Press the Capture / Stop button to begin the capture process.
Change the capture mode to Frequency Domain. Select an FFT Size and Average. Press the Capture / Stop button to begin the capture process.
Right click in the IIO Oscilloscope plot area. Select Single Tone markers. Press the Capture / Stop button to begin the capture process with markers.
Note the information in the Marker window. This capture shows a signal source of 50 kHz with harmonic components.
NOTE: This demo has AD463x configured by default to receive 24-bit differential and 8-bit common mode data over 4-Lane on SPI Mode.
There are a few software components that need to be installed in order to run this demonstration successfully:
-
Download Python 3.7 and run the installer
-
A typical installation location will be C:\Users\username\AppData\Local\Programs\Python
-
Edit the Windows System PATH environment variable to add the path to the Python directory
-
Edit the Windows System PATH environment variable to add the path to the Python\Scripts directory
- Use the following instructions to install PIP
- Download and run the latest LibIIO installer from the GitHub releases page here
-
Open a Windows CMD shell.
C:\Users\myuser> pip install pyadi-iio C:\Users\myuser> python -m pip install -U matplotlib
-
Download the python source code from the github repository
-
Run the Python source code. Open a Windows CMD shell
C:\Users\myuser\pyadi-iio\examples> python ad4630.py
This capture shows a signal source of 50 kHz with harmonic components.
NOTE: This demo has AD463x configured by default to receive 24-bit differential and 8-bit common mode data over 4-Lane on SPI Mode.
The following image shows the output data from Channel 0 of the 2 available channels in AD463x. The outputs from other channels can be obtained in a similar method by defining the relevant channel number in the given source code.
NOTE: The C examples provided are only tested on a Linux environment as mentioned here. The following example is demonstrated using the Arrow Ubuntu-64bit VM provided in the build prerequisites here.
There are a few software components that need to be installed in order to run this demonstration successfully:
- Follow this tutorial to directly install LibIIO dependencies on the host machine.
-
Download the C source code from the github repository
-
Compile the C source code (Use -liio flag to dynamically link the LibIIO libraries)
$ gcc ad4630-iiostream.c -o ad4630-iiostream -liio
-
Run the C executable (use your relevant target IP address here)
$ ./ad4630-iiostream ip:192.168.0.2
NOTE: This demo has AD463x configured by default to receive 24-bit differential and 8-bit common mode data over 4-Lane on SPI Mode.
The following image shows the output data from Channel 0 of the 2 available channels in AD463x. The outputs from other channels can be obtained in a similar method by defining the relevant channel number in the given source code.
NOTE: This demonstration requires a licensed version of MATLAB and Simulink along with the Communication Toolbox installed.
There are a few software components that need to be installed in order to run this demonstration successfully:
- Follow these instructions to install MATLAB and Simulink
- Use Add-On Manager to install Communication Toolbox in MATLAB
- Download and run the LibIIO installer from the GitHub releases page here
-
Download the MATLAB source from the github repository
-
Open the Simulink model DAQ4630.slx file
- Double click on the system object block of ad4630. Set your relevant target IP Address in the "IP Address".
- Set your preferred data capture mode by changing the register mode constants (OUT_DATA_MD, CLK_MD, DDR_MD and LANE_MD) in the file libiio_if.m. All constant values are currently set to driver default.
- Optionally set your preferred stop time or keep it as is. Run the simulation to see waveforms.
NOTE: Channels are arranged top-down with channel 0 on the top and channel 1 on the bottom.
This capture shows a signal source of 50 kHz with harmonic components.
NOTE: This demo has AD463x configured by default to receive 24-bit differential and 8-bit common mode data over 4-Lane on SPI Mode.
-
Power down the target. Type the following at the terminal prompt
$ poweroff
-
Wait until the linux terminal shows
$ reboot : System Halted
-
Close out IIO Oscilloscope and all associated windows
Please click Here to purchase platform boards
Arrow Data Storm DAQ Development Platform
Introduction
Developer Starter Guides
Additional Developer Docs
AD40xx Platform User Guide
AD7768 Platform User Guide
AD7768-1 Platform User Guide
AD7606B Platform User Guide
AD738x Platform User Guide
AD469x Platform User Guide
AD463x Platform User Guide
ADRV9001/2 Platform User Guide