Calibration explained

Every calibration NebulaOS has, one section each: what it fixes, what you need, where it is on the screen, how long it takes, and when to do it again. They all live in one menu, Tune → Calibration, and each runs as a guided page on the screen.

New printer? First calibration is the short path: Auto Calibration, then fine-tune on the first print. Come here when a print shows a problem - or start from the symptom in Improve your prints.

Golden rule: change one thing, then print a test. If you change five settings and the next print is worse, you will not know which one did it.

Before any test print, set up your slicer once: Setting up your slicer. Without its start and end G-code the print skips the mesh and purge line.

The Calibration menu

The Calibration menu, numbered in the order a new printer needs

The Calibration menu, numbered in the order a new printer needs.

The IN ORDER rows are numbered in the order a new printer needs them; below them, OTHER holds three you do not need on day one. The times are the screen's own.

# Menu row You need The screen says Section
1 Bed Tramming an empty bed (and maybe a printed shim) about 10 min Bed tramming
2 Heaters (PID) an empty, cool printer about 10 min Heaters (PID)
3 Axis Twist a sheet of paper about 5 min Axis Twist
4 Auto Calibration an empty bed - no tools about 7 min Auto Calibration
5 Input Shaper the accelerometer about 5 min Input Shaper
6 E-Steps a ruler or caliper, a marker about 5 min E-Steps
7 Skew Correction a printed test part, a caliper about 30 min Skew Correction
- Load Cell Calibration (OTHER) nothing (Automatic) or a 1.5 L bottle and a kitchen scale (Manual) 1-2 min Load cell
- TMC Autotune (OTHER, optional) nothing about 1 min TMC Autotune
- Bed Mesh (OTHER) nothing - Bed mesh

Every row except Bed Mesh is locked while a print runs.

The status line under every row

Status lines: what ran, when, and what it measured

Status lines: what ran, when, and what it measured.

  • Done 24 Oct - Z offset 1.752 mm, mesh range 0.16 mm (green): when it last ran and its result.
  • a one-line description and the time it takes (grey): not done yet.
  • Redo: Axis Twist changed (orange, with a bar on the left): something changed since, run it again.

The printer tracks two dependencies for you:

  • saving Axis Twist marks Auto Calibration Redo: Axis Twist changed;
  • a shim at the front-left corner during Bed Tramming marks both Load Cell Calibration and Auto Calibration Redo: a shim was added at front left.

Running a calibration clears its own Redo. On a printer whose NebulaOS does not keep a calibration history yet, the rows show the descriptions only.

From src/nebulaos_calibration_status.cpp:26-92 and src/calibration_menu_panel.cpp:205-214 at screen fd47cb6; the dependencies from extras/nebulaos_calibration_history.py:17-22 and extras/nebulaos_bed_tram.py:302-309 at extensions f498796.

Before you start: touch and mechanics

Touch. If taps land slightly away from where you press, run Settings → Reset → Reset touch calibration first. The screen shows three crosshairs in turn - tap the centre of each three times (lift your finger between taps). It takes about 30 seconds and survives reboots.

Mechanics. Software cannot fix loose hardware - it can only paper over it.

  • Belts: firm. A plucked belt should "thunk", not flap, and both sides should sound about the same pitch. Slack belts cause layer shift and ringing.
  • Gantry: square. The X bar should be parallel to the bed, not tilted.
  • Bed: not rocking. Gently push each corner - no play.
  • V-wheels/rails: snug but not binding. They should spin with light finger pressure.
  • Nozzle: clean, no plastic blob.

Bed tramming

Fixes One corner of the bed higher or lower than the others
You need An empty bed; on the stock KE, a few printed shims
Start it Tune → Calibration → 1 Bed Tramming, or the macro NEBULAOS_BED_TRAM in Mainsail
Takes About 10 minutes
Repeat when You changed the bed, its spacers or springs, or the first layer is thick on one side

The bed mesh corrects small hills in the bed. Tramming makes the four corners the same height first, so the mesh has less to correct. The printer measures the corners and tells you exactly what to do, one corner at a time.

Bed tramming, before it starts

The real screen on a printer running NebulaOS. Bed tramming, before it starts.

Start asks first:

The Start question: the printer will home and measure the four bed corners

The real screen on a printer running NebulaOS.

Your bed mount (asked once).

  • Rigid spacers. This is the stock KE: no knobs under the bed. You correct a low corner by adding a thin printed shim under it.
  • Rubber or springs. A common upgrade. You correct a corner by turning its screw.

The answer is remembered, and the screen confirms it ("Bed mount set to rubber or springs."). Switch to rubber/springs (or Switch to rigid spacers) on the page changes it.

How it works.

  1. The printer homes and measures all four corners (3 samples each). The screen shows "Measuring the four corners..." the moment you tap - keep your hands off the bed. If one probe touch is off, the printer measures that corner again by itself.
  2. When it is done, the head goes up to 100 mm at the middle of the rear edge, so you can lift the bed plate and reach every screw.
  3. The four corners are shown as a picture of the bed, front (the screen side) at the bottom. Each corner is compared with a reference corner, with a sign: minus is lower, plus is higher.
    • orange ADJUST - the corner to correct now;
    • green OK - within 0.10 mm; never selected again;
    • blue - the reference corner (rigid spacers: the highest corner; rubber or springs: the front-left corner, called base);
    • grey later - not yet; it comes after the current one.
  4. You get one instruction for the worst corner, for example "Front left: -0.23 mm. Add a 0.20 mm shim to raise it. Turn the printer off first, lift the bed plate at that corner and put the shim on the spacer." With rubber or springs it says which screw to turn, which way and how far (for example "Turn the screw an eighth of a turn counter-clockwise").
  5. Correct the corner, tap Done - measure again, and repeat until "Bed tramming complete".

The bed screws are M4x25.

Measuring the four corners

Measuring. The screen shows this as soon as you tap.

Rigid spacers: add a shim under the orange corner

Rigid spacers: the front-left corner is 0.23 mm below the highest corner - add a 0.20 mm shim.

Rubber or springs: turn the screw of the orange corner

Rubber or springs: every corner is compared with the front-left corner (base).

Tramming complete

Tramming complete: all four corners OK.

Tip from JDavid (community): rubber mounts, but keep the load-cell corner solid. Use the silicone (rubber) spacers on three corners, and keep the solid spacer on the front-left corner - the one with the load cell. Choose Rubber or springs: NebulaOS uses the front-left corner as the reference and never asks you to turn it, so you tram the bed with the other three screws. The load cell stays rigidly mounted, and automatic Z offset keeps working well.

Printed shims. Print a few thin washers that fit around the M4 bed screw (hole about 4.5 mm). Two each of 0.10, 0.20 and 0.30 mm cover most beds. The advice is rounded down to whole 0.10 mm steps, so it never asks for too much.

When it stops.

  • A corner did not improve after 2 adjustments: check that the screw and spacer at that corner are tight, and that nothing is bent or loose (bed, gantry).
  • A corner that was OK moved after another adjustment: check that every bed screw is tight, then start again.

Afterwards. If the front-left corner was shimmed or changed, the printer offers a load cell calibration - the load cell sits under that corner. Then run Auto Calibration.


Heaters (PID)

Fixes Bed or hotend temperature swinging around the target, which makes extrusion uneven
You need An empty, cool printer
Start it Tune → Calibration → 2 Heaters (PID)
Takes The screen says about 10 minutes; the hotend takes a few minutes, the bed longer
Repeat when You changed a heater, a thermistor or the hotend

Two buttons: Bed 65 C and Hotend 230 C - start with the bed. Each heats and cools a few times (the temperature going up and down is normal), then saves with one Klipper restart. The screen shows the progress: "Heating up", then "Measuring: cycle n of 6, about m min left". Each of the bed's swings takes about 3 minutes. The menu remembers both heaters.

Each button asks first:

The Heaters (PID) question for the bed

The real screen app.

The Heaters (PID) question for the hotend

The real screen app.

It comes before Auto Calibration on purpose: the hotend oozes during the long hot phase, and Auto Calibration's nozzle clean removes that before the Z offset is measured.

From the console instead: PID_HOTEND (default 230 °C) and PID_BED (default 65 °C), each with an optional TARGET=, then SAVE_CONFIG (calibration.cfg:161-178, firmware dc868e3).

Done when: the temperature holds flat at the target on the graph.


Axis Twist

Fixes First layer squished on one side and lifting on the other, and a new bed mesh does not help
You need A sheet of paper
Start it Tune → Calibration → 3 Axis Twist
Takes About 5 minutes
Repeat when You changed the X gantry hardware; otherwise once per printer

Axis Twist intro screen

The Axis Twist screen.

Why it happens. The printer probes the bed before each print and follows the resulting height map (the bed mesh). The probe point sits a little away from where the nozzle prints, and the X bar twists by a tiny fraction of a degree as it moves left to right. That twist tilts the probe just enough that the height it measures is not the height the nozzle prints at - so the bed mesh records the wrong number, and no amount of re-meshing fixes it. Axis Twist measures that error at five points across X and corrects every probe.

On the screen. The intro explains the paper test; homing and clearing the mesh happen automatically. Start it, and the page walks you through the 5 points (Point 1 of 5, step buttons, Accept). At each point lower the nozzle onto a sheet of paper until you feel light drag. Use the same drag feel at all 5 points - only the differences between them matter. At the end it shows the offsets; Save runs SAVE_CONFIG (Klipper restarts).

Save also removes the saved bed mesh (it was measured without the correction) and marks Auto Calibration Redo: Axis Twist changed - run Auto Calibration next.

From the console instead (clean nozzle tip first):

BED_MESH_CLEAR
AXIS_TWIST_COMPENSATION_CALIBRATE SAMPLE_COUNT=5

A Manual Probe box appears at each of the 5 spots: lower in small steps (-0.1, -0.05, -0.01) to light paper drag, then ACCEPT. After the fifth, SAVE_CONFIG.

Undoing it. The correction is saved in an [axis_twist_compensation] section in the SAVE_CONFIG block at the bottom of printer.cfg. Delete the saved values there and restart Klipper; running the calibration again simply overwrites them. NebulaOS's own section, with the KE values (X 20-200 at Y 117.5), is in machine.cfg (machine.cfg:325-331, firmware dc868e3).

Without that section the row shows "Axis Twist Compensation isn't enabled. Add [axis_twist_compensation] to printer.cfg." instead of opening; NebulaOS ships it.


Auto Calibration: Z offset and bed mesh

Fixes The first layer too high or too low everywhere, or patchy adhesion
You need An empty bed, no tools
Start it Tune → Calibration → 4 Auto Calibration, or NEBULAOS_AUTO_CALIBRATE in Mainsail
Takes About 7 minutes
Repeat when New nozzle or build plate, after Axis Twist, after a front-left shim, or when the row says Redo

One button runs, in order: a load cell check, homing, a nozzle clean, heating, a hot load cell check, the Z offset measurement and a bed mesh, then saves everything with one Klipper restart and verifies it. It also sets your Z adjustment from earlier prints back to 0 - it was made for the old Z offset. It does not do PID, Axis Twist, Bed Tramming or Input Shaper.

The step by step, what the screen asks and what you see at the end: First calibration.

If your slicer calls START_PRINT, each print also probes a fresh mesh of just the print area, on top of this saved one - see Print setup NebulaOS adds.

Fine-tuning on the first print

Print something with a large first layer and watch it. On the screen, Tune → Z Offset (or the Z buttons in Fine Tune, or tap the Z value on the print screen):

  • Raise (farther from the bed) when the line is rough or scraped, Lower (closer) when it is round and does not stick. Steps of 0.01 mm are usually right; 0.005 / 0.001 for the last bit.
  • Every tap is saved immediately. The page says Z offset adjustment: -0.040 mm, saved. The value comes back after a Klipper restart, a pause/resume and a power cut.
  • Reset sets the adjustment back to 0.
  • If the line ever says NOT saved (orange), the adjustment works for this print but is lost at the next restart.

Mainsail: its own Z offset arrows change the offset for the running print only (not saved by NebulaOS). Its Save button folds the current offset into the probe z_offset in printer.cfg and sets the NebulaOS adjustment to 0, so nothing is counted twice.


Bed mesh

Fixes Nothing by itself - it shows and measures the height map the first layer follows
Start it Tune → Bed Mesh, or Tune → Calibration → Bed Mesh (OTHER)
Repeat when Not needed: Auto Calibration saves one, and START_PRINT measures one for every print

The Bed Mesh page with a saved mesh

The real screen app, showing a saved mesh measured on a printer running NebulaOS.

Klipper does not load a saved mesh by itself after a restart, so after Auto Calibration the page shows the saved one instead, with Saved mesh 'default' - each print measures its own mesh at the start - nothing is loaded. Only when no mesh was ever saved it says No bed mesh yet - run Calibration > Auto Calibration. It can be viewed during a print. Every control on the page: Tune → Bed Mesh.


Load cell calibration

Fixes A Z offset measurement that fails, or a load cell check that does not pass
You need Automatic: nothing. Manual: a 1.5 L bottle full of water and a kitchen scale
Start it Tune → Calibration → Load Cell Calibration (OTHER), or NEBULAOS_LOAD_CELL_CALIBRATE in Mainsail
Takes 1-2 minutes. Nothing moves or heats
Repeat when You changed the front-left bed corner (shim, spacer, screw) - the row then says Redo

The KE measures the Z offset by gently touching the bed with the nozzle. The touch is felt by a load cell under the front-left bed screw. The page has two choices at the top:

  • Automatic (the default). The printer checks the sensor by itself on an empty bed: no bottle, nothing moves or heats. Tap Run. After a passed check the page says Ready - Automatic needs no weight calibration; Auto Calibration uses it. You do not have to run it by hand: Auto Calibration runs the same check first. If the check fails, the page says why and offers Run again or Use Manual.
  • Manual. The calibration with the bottle and the scale, below. The value you measure is used until you choose Automatic again.

The choice is saved at once and survives restarts.

Load cell calibration, before it starts

Load cell calibration, before it starts.

Manual, with a water bottle

  1. Empty bed. Remove everything from the bed; the nozzle must not touch it. Tap Check. The printer checks the sensor and takes the empty reading.
  2. Bottle on. Weigh the full bottle on the kitchen scale. Stand it with its centre roughly above the front-left screw head of the bed. Set the weight from the scale - on the screen, type it; in Mainsail, use the -100 … +100 buttons (1500 g is pre-filled). Tap Weigh.
  3. Lift it and put it back in the same place, then tap Continue. The printer shows "Printer measures N g, your scale said M g". They should agree.
  4. Remove the bottle, then tap Continue. The reading must return to zero.
  5. Optional finger test. Press the front-left corner gently and tap Measure. The printer shows the force. Tap Continue when done.
  6. Apply & Save. Klipper restarts with the new calibration.

Nothing is saved before step 6. Cancel works at every step.

Entering the weight of your bottle

Entering the weight of your bottle.

Calibration complete

Calibration complete.

If a step says Problem, it stays where it is. Fix the cause and tap the same button again:

Message What to do
The load cell sensor is not working properly Check the cable under the front-left corner.
The reading is not stable Don't touch the printer. Wait until the bottle stands still.
Enter the weight in grams, between 1000 and 5000 You typed a wrong number (for example 150 instead of 1500).
The printer barely felt the weight Put the bottle centred above the front-left screw head, or use two bottles.
The weight is too heavy Use a lighter weight.
The printer measures … your scale said … The bottle moved or touches something. Put it back and try again.
The bed does not return to zero Something is stuck on or under the bed.

Why a bottle is good enough. The Z offset itself does not depend on this calibration. It only sets how hard the nozzle may press (75 g) and the safety limit (2 kg). A bottle a little off the screw reads low, so the printer stops a touch a little earlier - the safe side. A typed weight far too low would be unsafe, which is why only 1000-5000 g is accepted.


Input Shaper

Fixes Ringing or ghosting: faint echoes trailing sharp corners on fast prints
You need The accelerometer
Start it Tune → Calibration → 5 Input Shaper (the workflow NEBULAOS_INPUT_SHAPER_CALIBRATE)
Takes About 5 minutes
Repeat when You changed the moving mass of an axis (belts, carriage, bed rails) - that axis only

The accelerometer is the Creality one for this printer. NebulaOS configures an ADXL345 on the KE's own SPI wiring - the same wiring the stock firmware uses - and drives it with upstream Klipper's [adxl345] and [resonance_tester]. The test runs to 90 Hz at 70 mm/s² per Hz, the same as Creality's stock firmware (machine.cfg:62-74, firmware 1.0.2).

Everything happens on the page, with no popups:

  1. Show graphs (on by default, remembered): draws a graph of each axis. Off saves a little time. It can only be changed between runs.
  2. Tap Start. The printer homes. Mount the accelerometer firmly on the toolhead and tap Continue.
  3. The page shows what is happening: Shaking X: 45 Hz (5-135 Hz), then Calculating the best shaper for X..., then Drawing the X graph....
  4. The X result (shaper type and frequency, remaining vibrations, smoothing, the highest acceleration that shaper allows) with its graph. Tap the graph to see it full screen, tap again to close. Move the accelerometer firmly onto the bed and tap Continue.
  5. The same for Y, then the result is saved with one Klipper restart.
  6. The end page shows both results and both graphs.

The graph shows the measured vibration (blue), what is left after the chosen shaper (orange) and the shaper itself (dashed). The latest graphs are also in Mainsail: Machine → config folder input_shaper/ (shaper_x.png, shaper_y.png). If a graph cannot be drawn, the page says why; the calibration itself still finishes. Cancel stops the run. From Mainsail or the console the run draws no graphs; NEBULAOS_INPUT_SHAPER_CALIBRATE GRAPHS=1 draws them.

To turn shaping off for one axis, set shaper_freq_x: 0 (or _y) in the config.


E-Steps (rotation distance)

Fixes Prints uniformly over- or under-extruded: walls thicker or thinner than sliced everywhere, not just at corners
You need A ruler or caliper, and a marker
Start it Tune → Calibration → 6 E-Steps (the workflow NEBULAOS_ESTEPS_CALIBRATE)
Takes About 5 minutes
Repeat when You changed the extruder gear or the hotend
  1. The hotend heats. Mark the filament at the extruder entry and tap Start Extrusion.
  2. The printer extrudes a fixed length.
  3. Measure how far the mark moved and type it in.
  4. The page shows the old and the new rotation_distance; Apply & Save saves it (Klipper restarts).

Repeat once to check. If the result keeps varying between runs instead of converging, that is an extruder hardware issue (skipping steps, loose grub screw, worn gears), not something calibration can fix. Done when: the extruded length matches what was asked within about 0.5 mm.


Skew Correction

Fixes Parts that come out as a slight parallelogram: two diagonals of different lengths
You need A printed test square and a caliper
Start it Tune → Calibration → 7 Skew Correction
Takes About 30 minutes, most of it the test print
Repeat when You changed or re-squared the frame

You only need it for parts that must fit something - skew is a fraction of a degree, invisible on a figurine. Quick check: measure the two diagonals of any printed square. Equal means no skew worth fixing.

Skew Correction panel

The Skew Correction screen.

  1. Print a square with your normal slicer profile - an XY skew calibration model, or a large flat square frame a few layers tall. Bigger is better: about 150 mm gives far more resolution than a small one. Note which corner was at the front left - that is corner A.

  2. Measure three lengths, outer corner to outer corner, as the part sat on the bed (front toward you):

    D (back-left) ───────────── C (back-right)
    │                                       │
    A (front-left) ──────────── B (front-right)
    
    Measure From → to
    A-C front-left → back-right (one diagonal)
    B-D front-right → back-left (the other diagonal)
    A-D front-left → back-left (the left edge)
  3. Enter them: tap each field and type the value (the keypad has a decimal point).

    Skew Correction with the number keypad open

    The real screen app.

  4. Tap Apply & Save. That sends SET_SKEW and runs SAVE_CONFIG (Klipper restarts).

From the console instead: SET_SKEW XY=<AC>,<BD>,<AD>, then SAVE_CONFIG. Undo: SET_SKEW CLEAR=1, then SAVE_CONFIG. The screen handles XY only; Klipper's XZ and YZ are console-only.

Without a [skew_correction] section the row shows "Skew correction isn't enabled. Add [skew_correction] to printer.cfg."; NebulaOS ships one (machine.cfg:337, firmware dc868e3). It does not fix a part that rocks, a loose belt or a bent axis - fix mechanics first.


TMC Autotune

Fixes Loud or warm stepper motors. It does not change print quality or dimensions
You need Nothing
Start it Tune → Calibration → TMC Autotune (OTHER, optional)
Takes About 1 minute, plus a Klipper restart
Repeat when You changed a motor

TMC Autotune with the KE's stock motors pre-selected

The real screen app, with NebulaOS's shipped configuration and motor list. A printer that has saved its own choices shows those instead.

For each stepper choose the Motor, then a Tuning Goal, then tap Save/Restart. Steppers without a saved choice are pre-selected with the KE's stock motors; nothing is written until you save. Recommended on the KE (the stock motors):

Stepper Motor Tuning Goal
stepper_x creality-42-34 performance
stepper_y creality-42-34 performance
stepper_z creality-42-40 silent
  • auto picks performance for X/Y and silent for Z - on the KE, exactly the table above.
  • performance - spreadCycle at all speeds (crisp, a bit more audible).
  • silent - stealthChop at all speeds (quietest).
  • autoswitch - experimental in the add-on; not needed on the KE.

The KE's TMC2208 drivers have no StallGuard, so there is no Sensorless Threshold field. Expect "noticeably calmer and cooler", not a different printer.

Save/Restart sends NEBULAOS_TMC_AUTOTUNE STEPPER=… MOTOR=… GOAL=… per stepper, then SAVE_CONFIG; from then on the tuned driver settings are applied at every boot. Undo one axis: set its Motor to Not Configured and tap Save/Restart.

The row is greyed out only when Klipper has no motor_database.cfg; NebulaOS ships it, from andrewmcgr/klipper_tmc_autotune in the extensions. TMC Metrics on the Tune tab is a different thing: a live driver dashboard.


Flow, pressure advance and temperature

These are tuned per filament in the slicer, not by NebulaOS. Do them after the first layer and the calibrations above are right. Tune → Fine Tune adjusts speed, flow and pressure advance live during a print. For the method, use the upstream guides:


After a hardware change

You do not have to redo everything - only what the changed part affects. Re-running a calibration overwrites the old value; there is no "reset first" step.

You changed… Redo
Nozzle, build plate 4 Auto Calibration, then fine-tune on the next print
Heater, thermistor or hotend 2 Heaters (PID), then 4
Shim at the front-left corner, or bed hardware (spacers, springs, the bed itself) Load Cell Calibration (Automatic: just Run), then 4
Corners uneven (first layer thick on one side) 1 Bed Tramming, then 4
X gantry, anything that could tilt the X axis 3 Axis Twist first, then 4
Moving mass on an axis (belts, carriage, bed rails) 5 Input Shaper
Extruder gear or hotend melt zone 6 E-Steps
Frame squareness 7 Skew Correction
A motor TMC Autotune

The front-left corner is special: the load cell sits under it, so changing that corner changes how the load cell is mounted.

Reset commands (rarely needed): skew → SET_SKEW CLEAR=1; active mesh → BED_MESH_CLEAR; shaper for one axis → shaper_freq_x: 0 (or _y) in the config.