SPT framework — validated guideline

Published from _docs/reference/spt-framework.md — edit it there, not here. Changes made in the wiki are overwritten on the next sync.

How the SPT application framework is meant to be used, and why it is shaped that way. Everything here was checked against the libraries this project actually compiles against.

This file is curated, not generated. No tool writes it. _docs/context/ is the opposite — derived from the twin and rebuilt wholesale — so the never-hand-edit rule applies there, not here.


Trust order

When two sources disagree about an identifier, believe them in this order:

  1. The installed library — TwinCAT_1/PLC/PLC_1/_Libraries/Beckhoff Automation LLC/SPT Base Types/3.9.0/SPT_Base_Types.library
  2. Official Beckhoff docs — https://beckhoff-usa-community.github.io/SPT-Libraries/
  3. This project's compiling code — TwinCAT_1/PLC/PLC_1/Modules/10 FG_Transport/ is the richest worked example (one EM with eleven submodules of three reusable types, plus a full recovery model); TwinCAT_1/PLC/PLC_1/Modules/11 FG_01/FG_01.TcPOU is the smaller one
  4. Third-party write-ups, including the white paper in _data/ — good for rationale, never for API

This order settles identifiers. For behaviour — sequences, handshakes, interlocks, recovery — the PLC is master outright and transport-behaviour.md records it.

This is not pedantry, and there are two distinct hazards:

Version drift. The docs site and the newest examples document V4; this project runs the V3.9 line. Every PackML enum literal differs (ePMLState_Idle here vs. E_PMLState.Idle there), and a few identifiers do too. Check every identifier against the installed 3.9.0 library before reusing any published V4 material.

Plain errors. The Getting Started page writes RegisterSubModule(); the function-block reference and the binary both say RegisterSubmodule. The class diagram has RegsterExernalController(). The V3.9 docs call a solenoid property ExtendedOutput where the library defines ExtendOutput — caught by the compiler, not by reading.

The binary settles both. Every identifier asserted below was found in the 3.9.0 library. Anything unverified is marked as such rather than stated.

What this project runs

TwinCAT 3.1.4026.25 — TcVersion in TwinCAT_1/PLC/TwinCAT.tsproj
SPT Base Types 3.9.0
SPT Components 3.9.1
SPT Event Logger / Motion Control / Utilities 3.9.0
PackML enum form E_PMLState.ePMLState_Execute, E_PMLCommand.ePMLCommand_Reset, E_PMLUnitMode.ePMLUnitMode_Production

The libraries are not in this repository. They come from Beckhoff-USA-Community/SPT-Libraries — MIT, © Beckhoff Automation LLC — installed by cloning that repository and adding its Library Repository folder to TwinCAT's library repositories, which is also how you pin or move a version. 01 · Setup has it with the rest of the prerequisites.

⚠ The white paper in _data/ is not ground truth

_data/SPT Framework.pdf — SPT Framework for TwinCAT 3: A Practical Guide, Articles 1–7 of a planned 12, Emad Eddin Abdelghany, 2025, free distribution — explains the architecture well. Its API surface does not match this project and must not be copied.

The paper says Verified reality How it was checked
M_Resetting(), M_Execute(), M_Stopping() … Resetting, Execute, Stopping — no prefix M_Resetting occurs 0 times in the 3.9.0 binary; official docs list the unprefixed names and write SUPER^.Resetting; FG_01.TcPOU compiles with SUPER^.Resetting(). The M_ prefix belongs to the inner PackML FB (StateMachine.M_StateComplete()), not to SPT
M_UnHolding(), M_UnSuspending() Unholding, Unsuspending capitalisation differs too
THIS^.StateComplete() is how you signal completion StateComplete exists but is PROTECTED; the application signals through the NoStateTasksToComplete / StateTasksComplete pair and the framework calls StateComplete() itself official docs state the pair explicitly; the binary contains StateTasksComplete := FALSE; … StateComplete();
Initialize := SUPER^.Initialize() behind a boolean guard a CASE ladder indexed by DescendantSequenceState official docs describe both indexers; the paper mentions neither
"every component tracks its own internal MainState" MainState is not a framework member — 0 occurrences. It is a variable the paper's own example declares easy to mistake for something inherited

The paper claims to document "V4", and this project is on the 3.9.x line — so some divergence would be expected. But the M_ prefix is not a version difference. The official docs site is the V4 reference, and it lists the state methods unprefixed and writes SUPER^.Resetting. So the prefix appears in neither line, and is best read as the author's own convention. (V4 library source was not inspected directly; that one claim rests on the docs rather than on a binary.)

Where the paper genuinely is describing V4 rather than erring, the V3.9 ⇄ V4 difference is what you need — most visibly the enum literals.

What the paper is good for: the ISA-88 reasoning, the hierarchy decision rule, the command-flow and completion-propagation model, and the registration failure modes. Nothing official contradicts any of it, and it is explained better there than anywhere else. Articles 8–12 — Control Source, Alarms and Events, Machine Code Progression, and the end-to-end example — are not written, so do not go looking for them. Its three figures are images and are not reproduced here.


The three levels

Machine Module (MM)          one per project, owns the PackML state machine
    Equipment Module (EM)    one functional section; "Submodule" in SPT terms
        Component            one device, or one logical concern

Each level has a fixed scope, and crossing it is the mistake that costs the most later:

Level Base class Owns Must not
Machine Module FB_PackML_BaseModule machine state, operator commands, coordination of EMs know how any device works
Equipment Module FB_PackML_BaseModule what its components do in each state touch %I* / %Q* directly
Component FB_ComponentBase one device: drive it, report status, raise its own alarms know which PackML state the machine is in

Placing something. Is it a physical device or a single logical concern → Component. Is it a group of devices that always work together as one functional unit → Equipment Module containing those components. Does it coordinate other units → the Machine Module, or a Submodule if genuinely warranted. More than three levels is discouraged.

An EM is not always required: a component belonging to the machine rather than to a station — a signal tower, say — registers directly with the Machine Module. In this project FG_System's H_SignalTower is exactly that case.

A component must run standalone. If it cannot be instantiated in a bare test program and driven through its own public methods, it is too tightly coupled to this machine and will not survive into the next one.

Command flow and completion

Top-down, each level commanding only its direct children:

operator → Control Source → MM enters Resetting → MM.Resetting()
                                                    → EM.Resetting()   (via SUPER^)
                                                        → components commanded

Bottom-up, by aggregation:

components report done → EM sets StateTasksComplete → MM sees all EMs done
                                                    → PackML advances Resetting → Idle

No level skips a level, in either direction. The MM never reaches past its direct children; a component never receives a command from the MM. Both directions work only because of registration.

Registration

Two methods, both called from Initialize(). Verified spellings — note the lowercase m:

Method Registers Interface
RegisterSubmodule() a child Equipment Module I_PackML_BaseModule
RegisterComponent() a child Component I_ComponentBase
RegisterExternalController() an HMI / control-source bridge I_PackML_ExternalController

Inheriting the right base class satisfies the interface automatically — no casting. Registration is what builds the internal arrays the framework iterates when propagating state calls, so:

Forgotten Symptom Compile error?
RegisterSubmodule for an EM its state methods are never called; it silently does nothing no
RegisterComponent for a component its CyclicLogic() is never called by the framework no
the InitComplete guard the state machine activates before components are ready no
Name alarms and traces carry an empty identity — you cannot tell which of four identical cylinders faulted no

None of these fail loudly. Register a child in the same edit that declares it.

Initialize()

Runs before the state machine exists. Its job is structure, not behaviour: register children, name them, link I/O, set fixed parameters. The framework calls it every scan until it returns TRUE.

Two indexers, never interchangeable:

Variable Use in Reset
SequenceState state methods (Resetting, Execute, …) automatic on state change
DescendantSequenceState Initialize only — SequenceState is reserved by the base Initialize manual

The shape this project uses, from FG_01.TcPOU:

Initialize := FALSE;

CASE DescendantSequenceState OF
    0:  // Names first - they are used in every alarm this module raises.
        Y_Gripper.Name := 'Y_Gripper';
        RegisterComponent(Y_Gripper);
        _LogModeChanges  := FALSE;
        _LogStateChanges := TRUE;
        DescendantSequenceState := DescendantSequenceState + 10;

    10: // Parameters that never change at runtime
        Y_Gripper.ExtendTime := 2000.0;
        DescendantSequenceState := DescendantSequenceState + 10;

    20: IF SUPER^.Initialize() THEN
            DescendantSequenceState := DescendantSequenceState + 10;
        END_IF

    30: Initialize := TRUE;
END_CASE

Never goes in Initialize(): motion commands, conditional production logic, or anything that must repeat after a fault and reset. Initialize() wires the structure; the state methods run the machine.

I/O linking. SPT documents a pattern in which a component takes its addresses from outside: a group-level I/O GVL passed in during Initialize(), either as a REFERENCE TO through a setter or ADR() into a POINTER TO. That keeps a component portable — point it at a different reference and it works on a different machine.

This project does not do that, and the shipped components do not either. FB_DigitalSensor declares HardwareInput AT %I* itself; FB_SingleSolenoidFeedback declares _ExtendOutput AT %Q*. Each instance is linked to a terminal channel directly, and there is no GVL_IO_<FG> anywhere in PLC_1. Only signals with no component that fits — bare coils like FG_01._LaserFire — are declared in the module.

The consequence is worth carrying: a component consumes terminal channels that appear in no GVL, so the group's channel count cannot be read off its module declaration. It is counted from the compiled process image instead.

CyclicLogic()

One call from MAIN drives the whole hierarchy. Every module's override opens with the init gate:

IF NOT _InitComplete THEN
    _InitComplete := Initialize();
    RETURN;
END_IF

SUPER^.CyclicLogic();

The execution order is fixed and holds at every level:

Step Why
1 children's CyclicLogic() so their status is current before anything reads it
2 your own logic acts on up-to-date child status
3 SUPER^.CyclicLogic() runs the state machine, calls the active state method
4 status derivation (components only) Busy / Error reflect this scan

Invert steps 1 and 3 and your state method evaluates last scan's child status — a one-scan lag that is harmless until it isn't.

Never call a child's CyclicLogic() conditionally. Skipping it stops that component's alarm monitoring and HMI processing and can stall its internal state machine. If something should not run every scan, put the condition inside the method, not around the call.

The body of an FB extending FB_CyclicFB stays empty — all code lives in methods.

State methods

Verified names on FB_PackML_BaseModule, no M_ prefix:

Aborted, Aborting, Clearing, Complete, Completing, Execute, Held, Holding, Idle, Resetting, Starting, Stopped, Stopping, Suspended, Suspending, Undefined, Unholding, Unsuspending

The official function-block page lists this state as Completed. That is the V4 spelling; the V3.9 line this project runs uses Complete, and Completed occurs 0 times in the shipped binary. The enum differs the same way — E_PMLState.ePMLState_Complete here versus E_PMLState.Completed in V4. Consult the installed library before reusing anything from the docs site, which documents V4.

Waiting — leave only on a command Acting — self-complete
Stopped, Idle, Suspended, Aborted, Held, Complete Clearing, Starting, Stopping, Aborting, Holding, Unholding, Suspending, Unsuspending, Resetting, Completing, Execute*

*Execute is the exception. It is an acting state but does not self-complete; it leaves on an explicit Complete command (ChangeState(E_PMLCommand.ePMLCommand_Complete)). For continuous production it simply never completes.

The acting-state shape, from working code:

CASE SequenceState OF
    0:  NoStateTasksToComplete := FALSE;      // there is work to do
        SequenceState := SequenceState + 10;

    10: Y_ReaderWindow.Retract();
        IF Y_ReaderWindow.Retracted THEN
            SequenceState := SequenceState + 10;
        END_IF

    30: StateTasksComplete := TRUE;           // finished
END_CASE

SUPER^.Resetting();                            // housekeeping - always last

NoStateTasksToComplete := FALSE tells the sequencer there is work; StateTasksComplete := TRUE says it is done. Both are re-initialised on state change, so neither needs managing. SUPER^.State() goes last — it propagates to registered submodules and aggregates their completion.

Omitting SUPER^.State() detaches submodules from the parent's state machine. That is occasionally a deliberate tool — the machine module uses it in Execute to sequence groups by hand — but never an accident.

Verified API inventory (SPT Base Types 3.9.0)

Everything below was extracted from the shipped library.

Function blocks: FB_BaseFB, FB_CyclicFB, FB_ComponentBase, FB_PackML_BaseModule, FB_ControlSource, FB_PackML_ModeLogger, FB_PackML_StateLogger

Interfaces: I_BaseFB, I_CyclicFB, I_ComponentBase, I_PackML_BaseModule, I_PackML_Control, I_PackML_ExternalController

Properties: Busy, Control, CurrentAlarmSeverity, CurrentMode, CurrentState, DisableSubModuleModeChange, Error, ErrorID, InSimulation, InitComplete, LogModeChanges, LogStateChanges, ModeCommand, Name, ParentResponseDefinitions, Registered, StateCommand, TracingAllowed

Structs / enums: ST_ComponentBase_HMI (+ _Command, _Config, _Status), ST_PackMLBaseModule_HMI (+ _Command, _Config, _Status), ST_PackML_Control, ST_PackML_Control_Simplified, E_AlarmResponse, E_PMLUnitMode

Methods beyond the state set: Initialize, CyclicLogic, StateComplete, RegisterSubmodule, RegisterComponent, RegisterExternalController, CreateEvents, Monitoring, HMICommunication, HMIPermissions, AllowHMIControl, BlockHMIControl, ComponentMonitor, SubModuleMonitor, RaiseAlarm, RaiseAlarmWithStrings, RaiseEventWithStrings, ChangeState, ChangeMode, StateChanged, ModeChanged, Reset, Complete, AbortImmediate, AbortImmediateError, HoldControlled, HoldImmediate, StopControlled, StopImmediate, SuspendControlled, SuspendImmediate, Trace, Marker, TraceWithJson, FB_init

Servo axes — FB_Component_BasicAxis (SPT Components 3.9.1, SPT Motion Control 3.9.0)

The lift carriages are NC axes on this component. Checked against the shipped libraries; none of it is obvious from the method names.

  • It wraps BasicAxis : FB_BasicAxis, which owns _Axis : Tc2_MC2.AXIS_REF. The PLC↔NC link therefore reads ….Y_Lift.BasicAxis._Axis.NcToPlc / .PlcToNc, and it lives in Mapping_PLC.xml beside the terminal links (owner TINC^NC-Task 1 SAF^Axes^…).
  • There is no Homed property. Read Y_Lift.Axis.Status.Homed.
  • Every Move*() is fire-and-forget. It returns TRUE when the command was accepted, and MoveAbsolute refuses (FALSE) while the axis is Busy unless AbortPrevious is set. Issue a move once, then watch the position — never re-issue it every scan.
  • The default velocity is the NC's slow manual velocity, loaded by the block's own Initialize, which runs after the owner's. Set Velocity before each move, not once.
  • Nothing enables the drive. MC_Power keeps its last Enable; call Enable() before moving. InhibitFeedPositive/Negative feed MC_Power's Enable_Positive/Negative every scan — the natural place for limit sensors.
  • The default reset routine is the CoE one (FB_ResetRoutine_CoEDrive, a plain MC_Reset). An AX5000 is SoE: assign FB_ResetRoutine_SoEDrive through ResetMethod.
  • No shipped home routine references on a sensor. SetZeroHere, SetPosition, AbsHoming and HardStop are what there is. A home method is any FB_CyclicFB that IMPLEMENTS I_MotionSequence — Axis : I_BasicAxis plus Execute() : BOOL, and the abstract CyclicLogic, which FB_BasicAxis calls every scan once it has set Axis := THIS^. It drives its own MC blocks on _Axis.Axis, because the axis' Move*() refuse while the home method keeps it Busy. FB_HomeRoutine_RefSensor (FG_Transport) is this project's.
  • FB_BaseFB initialises _Busy := TRUE. A home method that tests _Busy in Execute refuses until its first CyclicLogic; test your own step instead.
  • MC_SetPosition does not set Homed. MC_Home with MC_HomingMode.MC_Direct sets the position and the flag without moving.
  • HMI: AxisBase_HMI : ST_AxisBase_HMI — Command holds the four jog bits (honoured only with HMIControlAvailable, and only on an enabled axis), Status the set and actual values.

Build order — the official progression

From Beckhoff's Machine Code Progression. This is the guidance the white paper lists as an unwritten article; it exists.

  1. Plan. Agree the machine's operation and terminology with everyone involved before coding. Two questions to settle first: where are the possible mechanical collisions, and which alarms stop the whole machine versus only one Equipment Module?
  2. Build the Components. Hardware control first, written to be reusable.
  3. Build the Modules. Machine Module and Equipment Modules, where the state machine lives.

Then, within the modules, code Auto mode last:

Manual  →  Maintenance  →  Home  →  Pre-Production  →  Production (Auto)

Manual gives basic functionality; Maintenance adds the advanced and potentially damaging operations; Home establishes known positions across every EM; Pre-Production prepares the machine; Production is the automated sequence.

This matters here. Two groups are wired end to end — FG_Transport and FG_01 — and the other five are still twin only; check the group's own page rather than trusting this sentence to stay current. The twin's MIL sequences describe only the production case, so working straight from them produces Production mode first — the exact inversion of this guidance. Get a group homing and jogging under Manual and Maintenance before automating it.

FG_Transport learned the same lesson the expensive way, in a different register: its Resetting was written last and got rewritten three times before it stopped deadlocking. The rules that came out of it are in transport-behaviour.md — read them before writing any state method that waits on something.

Related

  • The FG_Transport behaviour contract — the derived handshake, the transfer latch, the lift interlocks and the reset model, and the handshake any EM here has to honour. The PLC is master for behaviour, and that page is where it is written down.
  • The machine in TwinCAT — the group index and how far each group has got.