FG_System in TwinCAT

This page is generated from the machine handoff and the TwinCAT solution. Published from _docs/context/fg-system.md — edit it there, not here. Changes made in the wiki are overwritten on the next sync.

The control side only. What FG_System is - its scene hierarchy, its devices and everything a human authored about it - is in the main repo: FG_System.

Twin PLC path MAIN.FG_System
Control PLC path MAIN.Machine.FG_System
Module FG_System EXTENDS FB_PackML_BaseModule
Served by —
Devices 10
Behaviour fg-system-safety.md

Components

Symbol Device type Twin FB Control PLC path I/O Linked
B_SafetyDoor11 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor11 3 3
B_SafetyDoor12 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor12 3 3
B_SafetyDoor13 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor13 3 3
B_SafetyDoor21 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor21 3 3
B_SafetyDoor22 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor22 3 3
B_SafetyDoor23 Lock FB_Lock MAIN.Machine.FG_System.B_SafetyDoor23 3 3
H_ControlPanel PanelSampler FB_Panel — ² 0 0
H_SignalTower PanelSampler FB_Panel MAIN.Machine.FG_System.H_SignalTower 4 4
SS_EStop1 Button FB_Button MAIN.Machine.FG_System.SS_EStop1 2 2
SS_EStop2 Button FB_Button MAIN.Machine.FG_System.SS_EStop2 2 2

² Not addressed under this group. Either the control PLC reaches it from another root (the operator panel is MAIN.ControlSource_Panel, not an FG_System member), or the type model this page was built from predates the device. Check the source banner above before treating it as a gap.

The twin path is not the control path. Only the control PLC path works in an HMI binding or a TcLinkTo pragma, and the twin's spelling fails silently in both.

SIM_1

POU TwinCAT_1/PLC/SIM_1/FG_System/FG_System.TcPOU
In .plcproj yes
Mapping targets GVL_EtherCAT_1_SIM
Mapping lines 43

Only the Mapping action is ours. The {region generated code} block belongs to OC Assistant and is overwritten on the next twin regeneration.

PLC_1

POU TwinCAT_1/PLC/PLC_1/Modules/01 FG_System/FG_System.TcPOU
In .plcproj yes
PackML states —
Fault codes —
HMI struct ST_HMI_FG_System

Fault codes are read from _FaultCode := in the ST. What each one means is behaviour and lives in the reference page named in the header.

Mapping

Process image member Dir Terminal Via
B_SafetyDoor11.ClosedSensor IN FG_System_Door_EL1809_1 channel 1 Mapping_PLC.xml
B_SafetyDoor11.LockOutput OUT FG_System_Door_EL2008_1 channel 1 Mapping_PLC.xml
B_SafetyDoor11.LockedSensor IN FG_System_Door_EL1809_1 channel 2 Mapping_PLC.xml
B_SafetyDoor12.ClosedSensor IN FG_System_Door_EL1809_1 channel 3 Mapping_PLC.xml
B_SafetyDoor12.LockOutput OUT FG_System_Door_EL2008_1 channel 2 Mapping_PLC.xml
B_SafetyDoor12.LockedSensor IN FG_System_Door_EL1809_1 channel 4 Mapping_PLC.xml
B_SafetyDoor13.ClosedSensor IN FG_System_Door_EL1809_1 channel 5 Mapping_PLC.xml
B_SafetyDoor13.LockOutput OUT FG_System_Door_EL2008_1 channel 3 Mapping_PLC.xml
B_SafetyDoor13.LockedSensor IN FG_System_Door_EL1809_1 channel 6 Mapping_PLC.xml
B_SafetyDoor21.ClosedSensor IN FG_System_Door_EL1809_1 channel 7 Mapping_PLC.xml
B_SafetyDoor21.LockOutput OUT FG_System_Door_EL2008_1 channel 4 Mapping_PLC.xml
B_SafetyDoor21.LockedSensor IN FG_System_Door_EL1809_1 channel 8 Mapping_PLC.xml
B_SafetyDoor22.ClosedSensor IN FG_System_Door_EL1809_1 channel 9 Mapping_PLC.xml
B_SafetyDoor22.LockOutput OUT FG_System_Door_EL2008_1 channel 5 Mapping_PLC.xml
B_SafetyDoor22.LockedSensor IN FG_System_Door_EL1809_1 channel 10 Mapping_PLC.xml
B_SafetyDoor23.ClosedSensor IN FG_System_Door_EL1809_1 channel 11 Mapping_PLC.xml
B_SafetyDoor23.LockOutput OUT FG_System_Door_EL2008_1 channel 6 Mapping_PLC.xml
B_SafetyDoor23.LockedSensor IN FG_System_Door_EL1809_1 channel 12 Mapping_PLC.xml
H_SignalTower.Blue OUT FG_System_Panel_EL2809_1 channel 11 Mapping_PLC.xml
H_SignalTower.Green OUT FG_System_Panel_EL2809_1 channel 12 Mapping_PLC.xml
H_SignalTower.Red OUT FG_System_Panel_EL2809_1 channel 9 Mapping_PLC.xml
H_SignalTower.Yellow OUT FG_System_Panel_EL2809_1 channel 10 Mapping_PLC.xml
SS_EStop1.HardwareInput IN FG_System_Panel_EL1809_1 channel 9 Mapping_PLC.xml
SS_EStop1.LampOutput OUT FG_System_Panel_EL2809_1 channel 13 Mapping_PLC.xml
SS_EStop2.HardwareInput IN FG_System_Panel_EL1809_1 channel 10 Mapping_PLC.xml
SS_EStop2.LampOutput OUT FG_System_Panel_EL2809_1 channel 14 Mapping_PLC.xml

26 members, 26 linked, 0 unlinked. A declared but unlinked signal compiles and is silently dead - see plc-io.md for the channel map and plc-io-exceptions.md for the ones that are unlinked on purpose.