Extended commands

Added by this project in driver/mappdk_ext.kl; needs this project's compiled .pc loaded to work. The upstream driver replies wrong-command for these.

Command Params Response Method
ver none fanuc-driver 0.2.0 sent automatically on connect
getreg :<5-digit zero-padded> number get_reg()
setreg :<5-digit zero-padded>:<value> success set_reg()
getpreg :<5-digit zero-padded> same as curpos get_preg()
setpreg :<5-digit zero-padded>:<6 values> success set_preg()
getdin :<5-digit zero-padded> 0 / 1 get_din()
getsysvar :<var name> number get_sys_var()
getalarm none id=..,sev=..,cause=..,time=..,prog=..,msg=.. get_alarm()
chkjnt :<axis count>:<N values> 0 / 1 check_joint()
chkpos :<6 values> 0 / 1 check_pose()
setsysvarnum :<var name>:<value> success set_sys_var_num()
getsreg :<5-digit zero-padded> string get_sreg()
setsreg :<5-digit zero-padded>:<value> success set_sreg()
getjpreg :<5-digit zero-padded> same as curjpos get_jpreg()
setjpreg :<5-digit zero-padded>:<axis count>:<N values> success set_jpreg()

Real-hardware verification status

setsysvarnum, getsreg/setsreg, getjpreg/setjpreg have all been verified on real hardware and are safe to use. getalarm can only read the most recent alarm, not history, details below.

setreg / getreg

Whether the value has a decimal point decides whether it's written as an integer or real register, so 1 and 1.0 are different. The Python side distinguishes them with int / float and doesn't normalize.

setpreg / getpreg

Same value format as movep. The driver keeps the current position's configuration and only overwrites the six XYZWPR values. If the configuration was never initialized, later motion can fail to find a solution.

getsysvar

Tries reading as an integer first, then as a real on failure. Override speed, UFRAME/UTOOL numbers, and the like all go through this instead of a dedicated routine per variable.

getalarm

Can only read the most recent alarm, not history. ERR_DATA's parameter formally looks like an input sequence number, but testing showed passing different numbers in always returns the same entry; the full debugging story behind this is in debugging notes. That approach has since been removed; to see full alarm history, go directly to the TP's 報警履歷 screen for now.

The message can contain commas, so it's the last field, and parsing only splits on the first five commas. ERR_DATA returns 7 fields at once; besides code/severity/message, cause (cause code), time (timestamp), and prog (the program running when it fired) come along too, and FanucRobot.get_alarm() returns them as a named Alarm type. time's actual unit and epoch haven't been checked against official documentation; treat it as an opaque number, don't use it for date arithmetic. Example at examples/alarm_status.py.

chkjnt

Uses KAREL's built-in J_IN_RANGE, not a self-maintained table of angle limits. The upside is it accounts for mechanical-coupling limits like J2/J3 too, since it's the controller's own judgment logic; the downside is it can only answer "is this position legal", not what the actual limit values are. A pure query, never moves the robot.

J_IN_RANGE needs the JOINTPOS6 type, not the generic JOINTPOS, or it throws INTP-311 Uninitialized data is used, and does so by hanging the entire server, with no response and no connection error (the Python side just times out). The MOVEJ routine has always used JOINTPOS6, so this follows the same convention and never had trouble.

J_IN_RANGE only returns legal or not, never which axis. When FanucRobot.check_joint() fails, it separately compares each axis against fanuc.limits.DEFAULT_JOINT_LIMITS_DEG; that table is a diagnostic aid only, not the source of legality, J_IN_RANGE is. The two can disagree: every axis checks out on its own but J_IN_RANGE still says illegal, meaning it's a pure mechanical-coupling limit (e.g. J2/J3) the table can't capture, and check_joint()'s result honestly reports that no violating axis was found rather than making one up.

chkpos

Uses the same CHECK_EPOS that movep (MOVEP in mappdk_cmd.kl) uses to judge reachability, a built-in already verified in production by movep, not something new and untested, so this one didn't need an incident first to find the right usage the way chkjnt did. The difference is it only computes the inverse kinematics of the target point itself, without simulating the whole path; two endpoints that are each reachable can still fail partway through a linear-interpolated path due to a configuration switch, and chkpos can't catch that.

getjpreg / setjpreg

The first version hung outright during real-hardware testing; the fix is in debugging notes.


Last updated: 2026-08-31