Notifications
You must be signed in to change notification settings - Fork 2
Protocol Commands Extended
Added by this project in driver/mappdk_ext.kl; needs this project's
compiled .pc loaded to work. The upstream driver replies
wrong-command for these.
| Command | Params | Response | Method |
|---|---|---|---|
ver |
none | fanuc-driver 0.2.0 |
sent automatically on connect |
getreg |
:<5-digit zero-padded> |
number | get_reg() |
setreg |
:<5-digit zero-padded>:<value> |
success |
set_reg() |
getpreg |
:<5-digit zero-padded> |
same as curpos
|
get_preg() |
setpreg |
:<5-digit zero-padded>:<6 values> |
success |
set_preg() |
getdin |
:<5-digit zero-padded> |
0 / 1
|
get_din() |
getsysvar |
:<var name> |
number | get_sys_var() |
getalarm |
none | id=..,sev=..,cause=..,time=..,prog=..,msg=.. |
get_alarm() |
chkjnt |
:<axis count>:<N values> |
0 / 1
|
check_joint() |
chkpos |
:<6 values> |
0 / 1
|
check_pose() |
setsysvarnum |
:<var name>:<value> |
success |
set_sys_var_num() |
getsreg |
:<5-digit zero-padded> |
string | get_sreg() |
setsreg |
:<5-digit zero-padded>:<value> |
success |
set_sreg() |
getjpreg |
:<5-digit zero-padded> |
same as curjpos
|
get_jpreg() |
setjpreg |
:<5-digit zero-padded>:<axis count>:<N values> |
success |
set_jpreg() |
setsysvarnum, getsreg/setsreg, getjpreg/setjpreg have all
been verified on real hardware and are safe to use. getalarm can
only read the most recent alarm, not history, details below.
Whether the value has a decimal point decides whether it's written as
an integer or real register, so 1 and 1.0 are different. The
Python side distinguishes them with int / float and doesn't
normalize.
Same value format as movep. The driver keeps the current position's
configuration and only overwrites the six XYZWPR values. If the
configuration was never initialized, later motion can fail to find a
solution.
Tries reading as an integer first, then as a real on failure. Override speed, UFRAME/UTOOL numbers, and the like all go through this instead of a dedicated routine per variable.
Can only read the most recent alarm, not history. ERR_DATA's
parameter formally looks like an input sequence number, but testing
showed passing different numbers in always returns the same entry; the
full debugging story behind this is in
debugging notes. That
approach has since been removed; to see full alarm history, go
directly to the TP's 報警 → 履歷 screen for now.
The message can contain commas, so it's the last field, and parsing
only splits on the first five commas. ERR_DATA returns 7 fields at
once; besides code/severity/message, cause (cause code), time
(timestamp), and prog (the program running when it fired) come
along too, and FanucRobot.get_alarm() returns them as a named
Alarm type. time's actual unit and epoch haven't been checked
against official documentation; treat it as an opaque number, don't
use it for date arithmetic. Example at
examples/alarm_status.py.
Uses KAREL's built-in J_IN_RANGE, not a self-maintained table of
angle limits. The upside is it accounts for mechanical-coupling limits
like J2/J3 too, since it's the controller's own judgment logic; the
downside is it can only answer "is this position legal", not what the
actual limit values are. A pure query, never moves the robot.
J_IN_RANGE needs the JOINTPOS6 type, not the generic JOINTPOS, or
it throws INTP-311 Uninitialized data is used, and does so by hanging the
entire server, with no response and no connection error (the Python
side just times out). The MOVEJ routine has always used JOINTPOS6,
so this follows the same convention and never had trouble.
J_IN_RANGE only returns legal or not, never which axis. When
FanucRobot.check_joint() fails, it separately compares each axis
against fanuc.limits.DEFAULT_JOINT_LIMITS_DEG; that table is a
diagnostic aid only, not the source of legality, J_IN_RANGE is. The
two can disagree: every axis checks out on its own but J_IN_RANGE
still says illegal, meaning it's a pure mechanical-coupling limit
(e.g. J2/J3) the table can't capture, and check_joint()'s result
honestly reports that no violating axis was found rather than making
one up.
Uses the same CHECK_EPOS that movep (MOVEP in mappdk_cmd.kl)
uses to judge reachability, a built-in already verified in production
by movep, not something new and untested, so this one didn't need an
incident first to find the right usage the way chkjnt did. The
difference is it only computes the inverse kinematics of the target
point itself, without simulating the whole path; two endpoints that
are each reachable can still fail partway through a linear-interpolated
path due to a configuration switch, and chkpos can't catch that.
The first version hung outright during real-hardware testing; the fix is in debugging notes.
Last updated: 2026-08-31
Controller Setup