Fleet management
Fleet management lets one node see every node on your channel and send commands to them. Each node keeps a list of the nodes and radios it hears. When you give a node a command for another node, it puts the command on the mesh, and the radios carry it across.
- Two or more nodes with the mesh turned on (System tab → Settings → Node & mesh → Mesh).
- Every radio on the same channel and key. See Meshtastic radio setup.
- A different node ID on each node. See How to run several nodes.
On a Full node, open the System tab → Fleet. It lists two groups:
-
Nodes have an ID of 2 to 5 letters or digits. Each row shows the node's mode, scan state, hits, uptime, temperature and GPS, taken from its
STATUSand heartbeat lines. A node counts as online if the list heard it in the last 2 minutes. - Other mesh radios are every other sender on the channel, including the radio paired with this node.
Ping Nodes sends @ALL STATUS, so every node answers and appears in the list. Clear empties both groups. The list holds 48 entries. A node stays on it after it goes quiet and after a reboot. Other radios drop off after 15 minutes of silence.
On a Full or Headless node, type FLEET in a USB serial monitor at 115200. The node prints one JSON line with itself, then each node and each other radio it has heard.
One Full node can control Headless nodes from its web UI. A fleet with no Full node works from the other rows. See Full or Headless.
| From | How | Build |
|---|---|---|
| The web UI | Status, Stop and Schedules on each node in the Fleet card. Scan tab → Schedule → Fleet plan for scans. The scheduler's node picker. Campaigns on several nodes. Remote calibration | Full |
| USB serial |
FLEET_SEND:<node> <command>, with a space between the node and the command |
Full and Headless |
| HTTP |
POST /api/fleet/send with node and cmd. See the API reference
|
Full |
| A radio on your channel, or the Command Center | The command with @<node> in front, such as @AH02 STATUS. This is an ordinary mesh command, not a fleet command |
Full and Headless |
For example, type this in a USB serial monitor on AH01:
FLEET_SEND:AH02 DEVICE_SCAN_START:2:300
AH01 replies FLEET_SEND:200 Sent to AH02. AH02's answer then appears on the same monitor as [MESH RX] AH02: DEVICE_SCAN_ACK:STARTED. In the web UI, the answers show on the Fleet plan rows and the node's Schedules list.
<node> is a node ID, or ALL. It cannot be the node you are typing on. <command> is one of these:
| Command | What it does |
|---|---|
STATUS, STOP
|
Reports status, or stops every scan |
DEVICE_SCAN_START:, SCAN_START:
|
Starts a device discovery or a target scan |
SCHED_ADD:, SCHED_LIST, SCHED_DEL:
|
Adds, lists or deletes scheduled scans |
CAMPAIGN_START:, CAMPAIGN_STOP, CAMPAIGN_STATUS
|
Starts, stops or reports a campaign |
BLE_CLASSIFY: |
Turns Bluetooth labeling on or off |
CALIBRATE:, CALIBRATE_RESET
|
Sets or clears distance calibration |
The node refuses every other command, including erase and settings commands. The reply is FLEET_SEND:<code> <reason>:
| Code | Meaning |
|---|---|
200 |
Sent |
400 |
Bad node ID, or a command that is not on the list |
409 |
Mesh is off |
413 |
The line is too long for one mesh message |
503 |
The mesh is busy. Send it again |
Every node keeps the fleet commands it hears for other nodes. If the node a command is for does not answer within 8 to 16 seconds, a node that heard the command sends it on, up to 3 hops. The answer comes back the same way. A node runs each command once, however many copies reach it. This works the same with Meshtastic and MeshCore radios.
A node that is on but missed a command asks for it. It does this when it hears two other nodes answer a command it never received. It then runs the command. A scan arrives with the time it has left. A node that was off does not get the commands it missed.
| Line | What it is | How often |
|---|---|---|
FLEET_AP:<mac> |
A Full node's access point address. The other nodes use it to avoid flagging that access point as an evil twin | About 10 seconds after boot, then every 30 minutes. Also when it hears a new node or a changed address, at least 30 seconds after its last send |
FLEET_RADIO:<node>:<name> |
The short name a node's Meshtastic radio puts in front of each line. Sentinel uses it to skip your own radios | When a node first sees a peer's name, then at most every 30 minutes per peer |
Time:... Temp:... GPS:... |
The status heartbeat | Off by default. Turn it on and set the interval under Node & mesh → Status heartbeat, from 1 to 60 minutes. The default is 30 |
- If the Fleet card shows no other node, click Ping Nodes. Then check that every radio carries the same channel and key.
- If a Fleet plan row says No answer from AH02 yet, no answer came within 3 minutes. Check that node's schedule later with Show.
- If
FLEET_SENDreplies409, turn the mesh on under Node & mesh.
See How to run several nodes for a full exercise, Scheduled scans for the schedule fields, and the mesh command reference for every command.
Start
- Choose your hardware
- Hardware and BOM
- Full or Headless
- Flash a node
- Meshtastic radio setup
- MeshCore radio setup
- First setup
- Web UI tour
- Data explorer
- Results timeline
Documents (PDF)
- Operator's Guide
- Assembly Manual
- Tier 1 Assembled
- Tier 2 Parts Kit
- Tier 3 Soldered Core PCB
- Tier 4 Bare PCB
Nodes
Several nodes
Find devices
- Target scan
- Device discovery
- Device classifier
- Probe requests
- Randomized MAC tracer
- Drone Remote ID
- Triangulation
Watch an area
Detect attacks
Capture and respond
Field exercises
- How exercises work
- Vehicle tripwire
- Locate a device
- Overnight watch
- Drone overwatch
- Defend your Wi-Fi
- Multi-node perimeter
- Alerts on your phone
Reference
- Command reference
- Mesh commands (full list)
- HTTP API
- Settings
- Privacy mode
- SD card
- Time and clock
- Heartbeat and Battery Saver
- USB serial
- Troubleshooting
Build