Skip to content

Vibration and tamper

Luke Switzer edited this page Nov 26, 2026 · 7 revisions

The node has a vibration sensor. When someone moves the node, it can send an alert over the mesh, start a scan on its own, or wipe its data.

How it works

The sensor is a small switch on the board that reacts to a knock or a lift. Each reaction counts as one vibration, and the node acts on it in up to three ways. These are separate settings, and you can use any of them together. The node has no software sensitivity setting. The trimpot (a small adjustable screw) on the sensor module sets how hard a knock it needs. The Operator's Guide §12.3 covers tuning it.

Start

  • Web UI: System → Settings → Sensors & power. Mesh alert and Scan on vibration are there.
  • Over mesh: @AH01 VIBRATION_ON turns the alert on, and @AH01 VIBSCAN_SET:1:device-scan:300:600 turns the scan on. @AH01 VIBRATION_STATUS and @AH01 VIBSCAN_STATUS report the settings.

Settings

Setting What it does Default
Mesh alert Sends VIBRATION: Movement detected at <time> to every radio on your channel. It sends at most one alert every 3 seconds. @AH01 VIBRATION_OFF turns it off On
Scan on vibration Runs one scan when the node is disturbed Off
Auto-erase Wipes the node's settings and SD files when it is moved. It needs an SD card and the erase key Off

Scan on vibration

Pick the scan, how long it runs, and how long to wait before it can run again. @AH01 VIBSCAN_SET:1:pcap:300:600 turns it on and runs a 300-second packet capture, with a 600-second cooldown. The node replies VIBSCAN_ACK:OK En:1 Mode:8 Dur:300s Cd:600s Pre:0.

Value Meaning
1 On (0 off)
pcap Which scan: device-scan, probe-scan, randomization-detection (MAC tracer), target-scan, drone-detection, deauth, baseline, or pcap (packet capture). none starts none. The numbers 1 to 8 in that order, and 0, also work
300 Scan length in seconds. 0 runs until STOP, except packet capture, which needs a set number
600 Seconds before it can trigger again, 5 to 86400
1 (fifth, optional) 1 lets the vibration scan interrupt a scheduled scan. The interrupted scan resumes afterward if at least 10 seconds of it were left. 0 means a vibration during any running scan does not start a new one. Left out, the node keeps the stored setting

@AH01 VIBSCAN_SET:0:0:0 turns the scan off. A packet capture that a vibration starts is an automatic capture, held to the limits on Packet capture. Battery Saver stops scanning, so a vibration does not start a scan while it is on. See Heartbeat and Battery Saver.

See Vehicle tripwire for the full exercise.

Auto-erase on tamper

Auto-erase wipes the node's settings and SD files if it is moved while auto-erase is on. It needs an SD card and the erase key, a password you set that authorizes every wipe. Secure wipe explains how to turn it on, its timers, and how many vibrations it needs.

If a scan starts on its own too often

Raise the cooldown, so a bumpy ride or a breeze does not start a scan every few seconds. The cooldown sets how often the node acts. For a sensor that fires too often or never, tune the trimpot in place, on the real mount.

Clone this wiki locally