Repository navigation
Heartbeat and Battery Saver
A heartbeat is a short status line a node sends to the mesh on a timer, so you know it is alive. Battery Saver is a mode that stops scanning and sends only a heartbeat, to make a battery last longer. They are two different things, and they send different lines.
The status heartbeat is off by default. When you turn it on, the node sends this line at the interval you set:
AH01: Time:2026-11-23_18:05:00 Temp:41.0C GPS:<lat>,<lon>
The GPS part appears only when the node has a fix. The line also prints on the node's USB serial port.
| Setting | Value |
|---|---|
| Turn on or off | System tab → Settings → Node & mesh → Mesh must be on, then Status heartbeat. Or @AH01 HB_ON and @AH01 HB_OFF
|
| Interval | 1 to 60 minutes. The default is 30. Set it in the same row, or with @AH01 HB_INTERVAL:10
|
The node does not send the heartbeat while a triangulation runs.
Use a longer interval when many nodes share one channel. Every heartbeat uses LoRa airtime that alerts also need.
Battery Saver stops all scans, turns off Bluetooth, lowers the CPU clock from 240 MHz to 80 MHz, and pauses Sentinel. The mesh and the access point stay on. The node reads GPS once a minute. It sends this line at the interval you choose, in place of the status heartbeat:
AH01: HEARTBEAT: Temp:41C GPS:<lat>,<lon> Battery:SAVER
It shows GPS:N/A when the node has no fix.
| Setting | Value |
|---|---|
| Start | System tab → Settings → Sensors & power → Battery saver. Or @AH01 BATTERY_SAVER_START:10
|
| Interval | 1 to 30 minutes. The default is 30 |
| Stop | The same switch, or @AH01 BATTERY_SAVER_STOP. The clock returns to 240 MHz and Sentinel resumes |
| Check |
@AH01 BATTERY_SAVER_STATUS replies with Enabled, the interval and the time to the next heartbeat |
Because scanning stops, a movement alert cannot start a scan while Battery Saver is on. See Vibration and tamper. To keep watching and still save power, pick the Relaxed scan profile instead. See Settings.
- If no heartbeat arrives, check that Mesh is on and that the radio has a LoRa region. See Meshtastic radio setup.
- If you see nothing after you turned Battery Saver on, check that Mesh is on. The node sends
BATTERY_SAVER: ENABLED Interval:<n>minwhen it starts, and the firstHEARTBEATright after.
Start
- Choose your hardware
- Hardware and BOM
- Full or Headless
- Flash a node
- Meshtastic radio setup
- MeshCore radio setup
- First setup
- Web UI tour
- Data explorer
- Results timeline
Documents (PDF)
- Operator's Guide
- Assembly Manual
- Tier 1 Assembled
- Tier 2 Parts Kit
- Tier 3 Soldered Core PCB
- Tier 4 Bare PCB
Nodes
Several nodes
Find devices
- Target scan
- Device discovery
- Device classifier
- Probe requests
- Randomized MAC tracer
- Drone Remote ID
- Triangulation
Watch an area
Detect attacks
Capture and respond
Field exercises
- How exercises work
- Vehicle tripwire
- Locate a device
- Overnight watch
- Drone overwatch
- Defend your Wi-Fi
- Multi-node perimeter
- Alerts on your phone
Reference
- Command reference
- Mesh commands (full list)
- HTTP API
- Settings
- Privacy mode
- SD card
- Time and clock
- Heartbeat and Battery Saver
- USB serial
- Troubleshooting
Build