Introduction

RLY-8 is a USB relay control module. You can control household appliances through USB wire. And with 8 relays, you could do some interesting project like power centralized management,romeot control, automatic production and so on. **Note:**When connect with HIGH-voltage, be aware of the wiring in case of Short-circuit causing damage to the devices as well as Personal Injury.

Specification

  • Power Supply: 7.5V DC @2A(Max) OR USB
  • Relay Max Switching Voltage: 277 AC
  • Relay Max Switching current: 10A
  • Relay Quantity: 8
  • Working Temperature: -30~85℃
  • Size: 145*90*40 mm
  • Weight: 490g( Including Package )

How To Use

Here, with a USB cable, you will learn how to use DRI0291.It's very easy, let's get start.

Device list

Hardware device list

  1. RLY-8 Relay Controller-USB x1
  2. USB-B cable x1
  3. 7.5V power adapter x1

Software list

  1. Computer software
  2. USB virtual serial driver

Connection Diagram

center

Device Instructions

  1. Install the USB virtual serial driver. center center center
  2. Open “Enternet_Com_Relay.exe” PC software, and select the right Serial port ID and Baud rate (Default:1200). center
  3. Open the serial port and input relay address (Default: 0x11). Click “Read the relay status”. center 4)Click “Open” and “Close” to control relay. center

Change Device Address

  1. Input old address (Default: 0x11) or broadcast address(0xAB). center
  2. Input new address(0x11~0x7F) in the blank, and click “Set address”. center

Change Device Baud rate

  1. Select right baud rate and click “Set baud rate”(Default:1200). center

Factory Reset

There is a reset button on the device, please hold it for 2 seconds, until the Led begin flashing, it will back to the default setting. And you could connect it with the default baud rate and address.