PB00003 DFRobot_UART_protocol_V1.0
Support a Master and multi-Slaves communication, the Master commands and Slave answers. Master needs not address but each Slave has a 1-byte address. 0xAB is broadcast address, using the address, all cascaded slaves will answer.
- Command format:
align = "center" colspan = 2 | Header | align = "center" | Destination Address | align = "center" | Data Length | align = "center" | Command Word | align = "center" | Data | align = "center" | Checksum |
---|---|---|---|---|---|---|---|---|---|---|---|
align = "center" | 0x55 | align = "center" | 0xAA | align = "center" | 1 Byte | align = "center" | 1 Byte | align = "center" | 1 Byte | align = "center" | 0~n Byte |
- Answer format : with the command in the same format; where " destination address " to " source address", " command word " is sent back to fill in the Master command word .
align = "center" | Command Word | align = "center" | Function | align = "center" | Command -data length(Bytes) | align = "center" | Command -data | align = "center" | Answer -data length(Bytes) | align = "center" | Answer -data |
---|---|---|---|---|---|---|---|---|---|---|---|
align = "center" | 0x02 | align = "left" | get measuring distance | align = "left" | 0 | align = "left" | null | align = "left" | 2 | align = "left" | distance value; the previous high, in mm |
align = "center" | 0x03 | align = "center" | get temperature | align = "left" | 0 | align = "left" | null | align = "left" | 2 | align = "left" | tenfold temperature; high front and signed, units of degrees Celsius; actual temperature value = tenfold temperature / 10 |
align = "center" | 0x04 | align = "center" | set measuring distance limit | align = "left" | 2 | align = "left" | distance value; the previous high , in mm | align = "left" | 1 | align = "left" | 0xCC = operation success, 0xEE = operation failed |
align = "center" | 0x05 | align = "center" | get measuring distance limit | align = "left" | 0 | align = "left" | null | align = "left" | 2 | align = "left" | distance value, the previous high , in mm |
align = "center" | 0x08 | align = "center" | set baud rate | align = "left" | 1 | align = "left" | baud identifier, see Note (1) | align = "left" | 1 | align = "left" | 0xCC = operation success, 0xEE = operation failed |
align = "center" | 0x55 | align = "center" | set Slave address | align = "left" | 1 | align = "left" | address | align = "left" | 1 | align = "left" | 0xCC = operation success, 0xEE = operation failed |
Note (1) : baud identifier description:
0x00: baud rate of 1200 bps
0x01: baud rate of 2400 bps
0x02: baud rate of 4800 bps
0x03: baud rate of 9600 bps
0x04: baud rate of 14400 bps
0x05: baud rate of 19200 bps
0x06: baud rate of 28800 bps
0x07: baud rate of 38400 bps
0x08: baud rate of 57600 bps
0x09: 115200 bps baud rate
0x0A: baud rate 128000 bps
0x0B: baud rate 256000 bps
The Master sends command to an ultrasonic module via UART interface, trigger the module start ranging, and then return the distance value.
Such as ultrasound module address is 0x11, and then the Master sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0x11
Data Length ----- 0x00
Command Word --- 0x02
Checksum ------- 0x12
Ultrasonic Module answer is : 0x55 0xAA 0x11 0x02 0x02 0x12 0x34 0x5A
Where the data: 0x12 as high byte of distance, 0x34 low byte
Distance value 0x1234, in millimeters, which is decimal 4660 mm .
Master reads the current temperature measured from ultrasonic module.
Such as ultrasound module address is 0x11, and then the host sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0x11
Data Length ----- 0x00
Command Word ----- 0x03
Checksum ------- 0x13
Ultrasonic Module answer is: 0x55 0xAA 0x11 0x02 0x03 0x00 0xFF 0x14
Where the data: 0x00 is high byte of temperature , 0xFF is low byte
That temperature is 0x00FF(decimal 255), which means that 25.5 degrees Celsius.
Master sets ultrasonic module address.
Such as setting ultrasonic module address is 0x11, then the host sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0xAB (broadcast address, you can use the original address)
Data Length ----- 0x01
Command Word --------- 0x55
Data ----- 0x11
Checksum ------- 0x11
Set successful answer from the ultrasonic module: 0x55 0xAA 0x11 0x01 0x55 0xCC 0x32
Return Data: 0xCC - Successful Operation
Slave address setting is successful; the module will use its new address to the host answer.
Master sets baud rate of ultrasonic module.
Such as ultrasound module address is 0x11, set the baud rate of 2400, the host sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0x11
Data Length ----- 0x01
Command Word --------- 0x08
Data --- 0x05
Checksum ------- 0x1E
Set successful answer from the ultrasonic module: 0x55 0xAA 0x11 0x01 0x08 0xCC 0xE4
Return Data: 0xCC - Successful Operation
You can set the measuring distance limit according to the application of ultrasonic module. While reducing the measuring distance limit, it can improve data output refresh rate from module.
Such as ultrasound module address is 0x11, to set the measuring distance limit 3840 (0x0F00) mm , the Master sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0x11
Data Length ----- 0x02
Command Word--------- 0x04
Data(High Byte) ------- 0x0F
Data(Low Byte) ------- 0x00
Checksum ------- 0x25
Set successful answer from the ultrasonic module: 0x55 0xAA 0x11 0x00 0x04 0xCC 0xE0
Return Data: 0xCC - Successful Operation
Such as ultrasound module address is 0x11, the Master sends:
Header --------- 0x55
Header --------- 0xAA
Destination Address ----- 0x11
Data length ----- 0x00
Command Word--------- 0x05
Checksum------- 0x15
Ultrasonic Module answer is: 0x55 0xAA 0x11 0x02 0x05 0x0F 0x00 0x26
Return Data: 0x0F00, which is decimal 3840 mm .
Arduino library link: DFRobot_URM library and samples.