HUITre

HUITre

Controller · 10 HP

HUITre (8re on the panel) is a pattern launcher with 8 slots. Each slot holds three voltages: a pattern CV and two extra CVs. Press a slot button to queue it; the change happens on the next measure trigger, so pattern switches stay in time. Each slot also has its own trigger (or gate) output.

Quick start

  1. Patch PTN to the pattern input of a sequencer (for example dTrOY or bordL).
  2. Patch a clock pulse that fires once per bar into STEP.
  3. Set the PTN knobs of the slots you use to the voltages that select your patterns.
  4. Press a slot button: it lights red (queued), then green on the next STEP pulse, and PTN, CV1, CV2 switch to that slot's values.

How to use it

  • Bar-synced pattern changes for dTrOY: PTN to the pattern input of dTrOY, a bar clock into STEP. dTrOY's pattern input moves one pattern per 0.625 V, so set the PTN knobs to 0.3, 0.9, 1.6, 2.2, 2.8 V... for patterns 1, 2, 3, 4, 5.
  • Song parts with extra settings: use CV1 and CV2 for things that change with each part: a filter cutoff offset, a transpose amount into a sequencer's transpose input, or the MORPH input of MOiRE.
  • Start things on a pattern change: leave GATE/TRIG blue (trigger) and patch a slot's small output to a reset input or an envelope. It fires a 1 ms trigger when that slot becomes active.
  • Mute groups: switch GATE/TRIG to green (gate). Each slot output is now 10 V while its slot is active; patch them to VCA CV inputs (for example VCV VCA) to turn a different part on per slot.

Controls

Control Range Description
GATE/TRIG (LED button) Blue: trigger / Green: gate Mode of the 8 slot outputs.
Slot buttons 1-8 button Queue this slot. Light: green = active, red = queued.
PTN 1-8 0-10 V Pattern CV of each slot. Defaults 0, 1.25, 2.5 ... 8.75 V.
CV1 1-8 0-10 V First extra CV of each slot.
CV2 1-8 0-10 V Second extra CV of each slot.

Inputs

Input Description
STEP (measure) Rising edge: the queued slot becomes active. Unpatched: a slot becomes active as soon as you press it.

Outputs

Output Description
Slot outputs 1-8 (small jacks, right) Trigger mode: a 1 ms, 10 V trigger when the slot becomes active. Gate mode: 10 V while the slot is active.
PTN PTN value of the active slot.
CV1 CV1 value of the active slot.
CV2 CV2 value of the active slot.

Notes

  • A trigger is sent only when the active slot changes; pressing the slot that is already active does nothing.
  • Saved with the patch besides the knobs: the GATE/TRIG mode and the active slot. Initialize goes back to slot 1 in TRIG mode.
  • Monophonic.

Clone this wiki locally