Skip to content

FastHenry Accuracy

github-actions[bot] edited this page Nov 19, 2026 · 1 revision

22.3 FastHenry Accuracy

Where the FastHenry bridge's errors come from, how big each one measured on E01, E02 and the coil board, and what the bridge leaves out of the physics. Every number here is from the runs on the FastHenry_Integration branch (Examples/E01_circular_loop/results.json, Examples/E02_coaxial_loops/results.json, the coil board's Results/), and from the filament study in the branch's Examples/Inductive Coils/README.md.

22.3.1 No Mesh In The Air, No Iteration

Two of the usual sources of a field solver's error are not there:

Source In FastHenry What it means
The air's mesh and its outer boundary none: every filament couples to every other through its partial inductance, worked out exactly, and the space round the copper is not discretised no air grading to refine and no domain size to choose
The iterative solve none: the dense direct solve (-s ludecomp -m direct) factorises the whole system the answer is the exact answer of the filament model; the impedance matrix comes out symmetric to the last digit, which is checked on every solve (reciprocity)

What is left is how well the filaments draw the copper and its current: the split of each track's section, the chords of an arc, and the rotor's grid of bars.

Note

FastHenry's own default, GMRES with its multipole speed-up, left M from the TX to a receiver and M back 2.7 % apart on the coil boards, and is not used. The multipole refinement is also off (-a off): at the 1 mm gap, where both ways ran, they gave the same numbers to 3 parts in 10⁸.

22.3.2 The Error Budget On E01

Each line changes one thing and keeps the rest.

Source Test Effect
Filaments across the trace, at 10 kHz 1 → 3 → 5 → 9 across, 1 through L +0.24 %, +0.08 %, +0.04 % (55.343, 55.474, 55.516, 55.538 nH)
Filaments through the copper, at 10 kHz 9 × 1 → 9 × 3 L +0.07 % (55.579 nH)
Finer still, at 10 kHz 9 × 3 → 15 × 3 L +0.002 % (55.580 nH): settled
The chords 126 straight strips, 0.5 mm wide, in place of the ring R at 10 kHz 0.011 % over the annular sector (61.208 against 61.201 mΩ), the chords' own value worked by hand (61.207 mΩ)
The reference's own approximations Neumann's integral with the GMD of a straight bar used on a ring of R / g = 84 of order (g / R)², 1e-4
FastHenry against the reference Neumann's double integral over the open arc L −0.02 % from 9 × 3 on, settling from below; R +0.011 %

At 3.5 MHz, where the skin depth equals the copper's thickness and no formula is exact, the ladder shows how many filaments the crowding of the current needs:

E01 at 3.5 MHz 1 × 1 3 × 1 9 × 1 15 × 3
L 55.343 nH 54.899 nH 54.771 nH 54.797 nH
R 61.207 mΩ 69.946 mΩ 75.099 mΩ 75.433 mΩ

One filament holds the current uniform, so it misses the rise of R altogether. With 3 × 1, the coil board's setting, E01 reads L at 3.5 MHz 0.2 % high and R 7 % low on its 0.5 mm trace. From 9 × 3 on, L and R move by 0.01 % and 0.08 %.

22.3.3 Mutual Inductance On E02

M is the number the coil board's signal rests on.

E02, M at 10 kHz 1 × 1 3 × 1 9 × 3
FastHenry 23.891 nH 23.892 nH 23.892 nH
Against Neumann's integral (23.886 nH) +0.022 % +0.024 % +0.024 %

M hardly depends on the filaments: FastHenry works out the coupling of two bars from their whole cross-sections, so even one filament per segment is within 0.004 % of the finest. The 0.024 % left is of the size of the reference's own approximations: it averages Neumann's integral over 21 × 21 radii across the two traces' widths with the current uniform across each, leaving out the traces' thickness and the current's slight lean to the inside of a ring.

22.3.4 The Coil Board

The coil board runs at 3 filaments across each track and 1 through, the edge ones twice as narrow, and a rotor grid of bars 0.05 mm wide at its edges growing to 0.3 mm. What that setting costs was measured on a sibling board of the same family at 1 mm and 0° (the branch's Examples/Inductive Coils/README.md):

Change from the setting used M SIN and M COS L TX R TX
1 filament across instead of 3 0.2 % 0.04 %
5 filaments across instead of 3 0.03 % 0.01 % +1.5 %
2 filaments through instead of 1 0.01 % 0.1 %
A finer rotor grid (0.025 to 0.2 mm bars) 0.04 %
Finer still (0.02 to 0.15 mm) 0.005 % more

So M and L TX are settled to a few hundredths of a percent. R TX is the number that still moves, because at 3.5 MHz the skin depth (35 µm) is the copper's thickness and the current crowds to each track's edges more finely than three filaments follow; on the coil boards' 0.2 to 0.3 mm traces 3 × 1 reads R about 2 % low.

On S0d2_1x_OD23_2L_tiny_TX3top_Cut itself, every one of its 81 solves was reciprocal to the last digit, and the best sine through each gap's 16 solves leaves 0.018 to 0.019 nH rms at 1 mm, against an amplitude of 4.73 nH. The solves at θ and θ + 180° came out as the same numbers, as the two-sector rotor's symmetry asks: turning the rotor moves only its grid, never the stator's filaments, so there is no meshing noise between angles.

22.3.5 What The Bridge Leaves Out

What In the bridge What it does to the numbers
Displacement current none: FastHenry's magneto-quasi-static formulation no capacitance between turns and no self-resonance; the answer holds only well below the coil's self-resonance
The insulators FR-4, solder mask and air are not in the model right for the magnetic field, since they are μr 1 and σ 0
The copper's conductivity 5.8 × 10⁷ S/m, one value for all copper copper at 20 °C; temperature is not followed
The current inside a filament uniform along it and across it the current's spread across a track is drawn only as finely as its filaments (37.2)
The copper's shape each track a straight bar along its centre line, its width and its layer's thickness; arcs as chords a track's round ends and a via's pads are not modelled, only its centre line, width and barrel; on the coil board they are a small part of the copper. The etched trapezoid and the copper's roughness are not in the model
Boards, not arbitrary 3D copper flat at its layers' heights a board over another (a rotor over a stator) works; a part tilted out of the board's plane does not
The terminals a port between two nodes; at a cut, the copper inside the 0.2 mm cut taken out the leads to the IC are not modelled

22.3.6 What To Trust

Quantity On boards like E01, E02 and the coil board
L at 10 kHz within 0.02 % of Neumann's integral from 9 × 3 on; 0.2 % low at 3 × 1
M within 0.024 % of Neumann's integral at any filaments; on the coil board settled to a few hundredths of a percent
R at 10 kHz the chords' DC resistance, 0.011 % over the ring's
R at 3.5 MHz, skin and proximity effect no exact reference; it needs filaments across: settled from 9 across on E01, about 2 % low at the coil board's 3 × 1
Reciprocity to the last digit on every solve: a check on every run, at no cost
SIN and COS, the angle error from M, so as good as M; every solve's M is read only once its reciprocity check passes

How FastHenry's numbers compare with the other solvers' on the same boards is on Solvers Comparison.

Previous Next
PyPEEC Accuracy Palace Accuracy

Clone this wiki locally