Skip to content

Elmer FEM Walkthrough

github-actions[bot] edited this page Nov 19, 2026 · 1 revision

Caution

The bridge lives on the Elmer_Integration branch.

19.1 Elmer FEM Walkthrough

Elmer is an open-source finite element solver from CSC in Finland. The Elmer bridge turns a KiCad board into an Elmer simulation: KESE exports the board's 3D geometry, the bridge meshes it, writes Elmer's case, runs ElmerSolver and reads the answer back. KESE itself stays what it is, a geometry exporter, and is never changed by the bridge. This page walks through it from top to bottom: what Elmer does here, installing it, and every step from a board file to the numbers.

Note

Three boards are shown on the Elmer FEM pages. The two proof boards, E01 (one loop) and E02 (two coaxial loops), check the bridge against textbook formulas. The inductive encoder coil S0d2_1x_OD23_2L_tiny_TX3top_Cut is a whole sensor, a stator and a rotor, solved at 16 rotor angles and 5 air gaps: 81 Elmer solves, every one of which passed its two checks. All three have run; their results are on Elmer FEM Test Boards And Results.

19.1.1 What Elmer Is Used For Here

At the frequencies of inductive position sensors and planar coils (kHz to a few MHz) a board is a tiny fraction of a wavelength across: a 40 mm coil at 3.5 MHz is about 1/2000 of a wavelength. The physics is then magneto-quasi-static: currents and magnetic fields, eddy currents in nearby copper, and no wave propagation. Elmer's time-harmonic A-V solver with edge elements (WhitneyAVHarmonicSolver) solves exactly this, so it is the main solver for:

Quantity How the bridge gets it
Inductance L of a coil the imaginary part of the coil's impedance V / I, over ω
AC resistance R of a coil, with skin and proximity effect the real part of V / I
DC resistance from the potential that sets each coil's current direction
Mutual inductance M between two coils the open-circuit voltage of the undriven coil over the driving current
The field energy, as a check on L Elmer's field energy W gives L = 2W / I²
The eddy power, as a check on R Elmer's eddy current power P gives R = 2P / I²
The effect of a conducting target (a rotor, a plate) the same quantities with the conductor present and away
An encoder's SIN and COS curves and its angle error M from the TX to each receiver at a series of rotor angles, fitted with a sine

What Elmer does not give here: the coils' capacitance and self-resonance. An eddy-current solve has no displacement current, so those need another solver; how the solvers of this project divide the work is on Solvers Comparison.

19.1.2 How It Fits Together

flowchart TB
    subgraph S1["KESE exports the board"]
        direction LR
        A[KiCad board<br>.kicad_pcb] -->|run_KESE.py --for elmer| B[STL per net<br>+ materials.json]
    end
    subgraph S2["The bridge builds the Elmer case"]
        direction LR
        C[2.5D mesh<br>wedges + tetrahedra] -->|bridge/ports.py| D[coil electrodes<br>and port sheets] -->|bridge/elmer_case.py| E[Elmer case<br>.sif + circuits]
    end
    subgraph S3["Elmer solves, the bridge reads out"]
        direction LR
        F[V and I of every coil] -->|bridge/study.py| G[L, R, M<br>results.json]
    end
    S1 -->|bridge/mesh25d.py| S2
    S2 -->|ElmerSolver| S3
Loading

Each step is described below, from 19.1.8 on.

19.1.3 The Elmer FEM Pages

Page What it covers
Elmer FEM Walkthrough (this page) What Elmer does here, installing it (19.1.5), and every step from the board file to the numbers (19.1.8 on)
Elmer FEM Simulating Your Own Board Every setting of an example's simulation.py, how to start a new one, and the memory a board needs
Elmer FEM Test Boards And Results E01, E02 and the coil board, and what came out on each
Elmer FEM Accuracy Where the errors come from and how big they are
Elmer FEM Troubleshooting What went wrong while building the bridge, and the fixes

How Elmer sits beside the project's other solvers is on Solvers Comparison.

19.1.4 Where The Code Is

Folder on Elmer_Integration What it holds
bridge/ The bridge, in Python: geometry.py, mesh25d.py, ports.py, elmer_case.py, study.py, and setup_machine.sh, which sets up a fresh Ubuntu 24.04 machine
Examples/E01_circular_loop/, Examples/E02_coaxial_loops/ The proof boards, each with its board, make_board.py, simulation.py, README.md and results.md
Examples/Inductive Coils/S0d2_1x_OD23_2L_tiny_TX3top_Cut/ The coil board: Boards/ (from the generator), 3D_Geometry/ (KESE's export), Elmer Simulation/ (test_spec.json, simulation.py and the chart scripts) and Results/ (non-commercial licence, see that folder's LICENSE.md)
Examples/Inductive Coils/new_coil.py Sets up any single coil set from the generator as a folder like the coil board's
Solver_Elmer/install/ The Elmer 26.2.1 build every example ran on, for Ubuntu 24.04 (see 19.1.5)
3D_Geometry/ Empty on purpose: KESE's Generator/ is copied here from main, or KESE_PATH points at it

The branch also solves five more coil boards made from the same small coil set; they are in Examples/Inductive Coils/.

19.1.5 Linux (Ubuntu 24.04)

The bridge needs three things: Elmer with OpenMP and the MUMPS direct solver, a Python environment with the bridge's packages, and a copy of KESE. The branch carries the Elmer every example ran on, built for Ubuntu 24.04, in Solver_Elmer/install/; it never carries KESE, so 3D_Geometry/ is empty on purpose and is filled by hand.

The Committed Elmer

Solver_Elmer/install/ is Elmer 26.2.1 with MUMPS, built for 64-bit Linux on Ubuntu 24.04. It only needs the libraries it runs with, installed once:

sudo apt-get install -y libgfortran5 libgomp1 libopenblas0 libopenmpi3t64 libmumps-5.6t64
cd Solver_Elmer
ldd install/lib/elmersolver/libelmersolver.so | grep 'not found'     # prints nothing when every library is there
install/bin/ElmerSolver -v | grep -m1 Version

The bridge looks for Solver_Elmer/install/bin/ElmerSolver and tells Elmer that install/ is its home, so the folder works wherever the branch is checked out. To run Elmer by hand rather than through the bridge, set ELMER_HOME to that install folder first; without it Elmer stops with elements.def not found.

What the build is
Source ElmerCSC/elmerfem, tag release-26.2.1, commit a19504a, unmodified
Built 15 November 2026, Ubuntu 24.04, GNU Fortran 13.3.0, Release
With MPI (Open MPI), OpenMP, MUMPS 5.6 from Ubuntu; no ElmerGUI, no Hypre, no ParMETIS
Licence GPL-2.0 or later, its library LGPL-2.1; the texts are in install/share/elmersolver/license_texts/

One Command For A Fresh Machine

bash bridge/setup_machine.sh

installs the libraries above, the system libraries gmsh's wheel needs, and the Python packages of requirements.txt into .venv at the branch's root. It is safe to run again, and builds Elmer from source only if Solver_Elmer/install/bin/ElmerSolver is missing.

Building Elmer Yourself

The commands that made install/:

sudo apt-get update
sudo apt-get install -y build-essential cmake git gfortran libopenmpi-dev libblas-dev liblapack-dev \
    libopenblas-dev libmumps-dev libscalapack-openmpi-dev
cd Solver_Elmer
git clone --depth 1 --branch release-26.2.1 https://github.com/ElmerCSC/elmerfem.git elmerfem
mkdir build && cd build
cmake ../elmerfem -DCMAKE_BUILD_TYPE=Release -DWITH_ELMERGUI:BOOL=FALSE -DWITH_MPI:BOOL=TRUE \
    -DWITH_OpenMP:BOOL=TRUE -DWITH_Mumps:BOOL=TRUE -DCMAKE_INSTALL_PREFIX=$PWD/../install
make -j"$(nproc)" install

Note

ParMETIS is left out on purpose: nothing in install/ links it (checked with ldd on every binary and library), and its licence is not an open-source one. elmerfem/ and build/ stay out of git.

Important

Keep MUMPS in the build. The coil board solves its field with MUMPS, the bridge solves each coil's current direction with UMFPACK, and Elmer's Circuit preconditioner for the iterative solve factorises the circuit block with a direct solver; without one it stops with Preconditioner "circuit" needs either Umfpack or MUMPS.

Python

python3 -m venv .venv
.venv/bin/pip install -r requirements.txt       # numpy, scipy, shapely, trimesh, gmsh, mapbox_earcut

KESE

Copied from main so that run_KESE.py sits directly in 3D_Geometry/:

git -C <your KESE clone> archive main Generator | tar -x --strip-components=1 -C 3D_Geometry
.venv/bin/python 3D_Geometry/run_KESE.py --help

or leave 3D_Geometry/ empty and point the bridge at any KESE with export KESE_PATH=<path to Generator>. KESE runs inside the bridge's Python, so its own packages (requirements.txt in Generator/) must be in the same environment. The coil board does not need KESE to run: its export is committed in its own 3D_Geometry/ folder and is reused while the board is unchanged.

Check The Whole Chain

With the first proof board, on its coarsest mesh at 3.5 MHz:

cd Examples/E01_circular_loop
../../.venv/bin/python simulation.py --levels 0.75 --freqs 3.5e6 --out case_check --results check.json

The committed results give L 52.93 nH and R 80.19 mOhm for this solve (3 minutes on the 4-core test machine), the level 0.75 values of Elmer FEM Test Boards And Results; its own --results file keeps the committed results.json as it is. Those results were made with the bridge of 15 and 16 November (Elmer FEM Test Boards And Results), so today's bridge may differ in the last digits.

A Swap File For The Coil Board

The coil board's direct solves need more memory than a 16 GB machine has (Elmer FEM Simulating Your Own Board). On Linux a swap file makes up the rest:

sudo fallocate -l 26G /swapfile && sudo chmod 600 /swapfile && sudo mkswap /swapfile && sudo swapon /swapfile

19.1.6 Windows

The committed build runs inside WSL with Ubuntu 24.04, the same way as on Linux. It does not run on Windows itself, on macOS, or on another Linux release without its libraries at these versions.

Route Steps Notes
WSL 2 (recommended) Install Ubuntu 24.04 from the Microsoft Store, then follow 19.1.5 inside it The bridge, KESE and Elmer all run as on Linux. Keep the repository inside the WSL file system (not under /mnt/c), which is many times faster for the mesh files
Native Build Elmer with the instructions in Elmer's repository (MSYS2) and install it into Solver_Elmer\install; install Python 3.11 or later from python.org; py -m venv .venv and .venv\Scripts\pip install -r requirements.txt The bridge calls ElmerSolver from Solver_Elmer/install/bin, so that folder must hold ElmerSolver.exe. Not yet run on the test boards

macOS has the same route as native Windows: build Elmer with the instructions in its repository and install it into Solver_Elmer/install.

19.1.7 What The Test Machines Had

Item Version
OS Ubuntu 24.04; E01 and E02 on 4 cores and 15 GB, the coil board on 16 GB machines with a swap file
Elmer 26.2 (release 26.2.1, a19504a, OpenMP, MPI, MUMPS, UMFPACK)
Python 3.13
gmsh 4.15.2 (from PyPI)
numpy, scipy, shapely, trimesh 2.5.3, 1.18.1, 2.2.0, 5.2.1

Each example writes the versions it ran with into its results files, so every number on Elmer FEM Test Boards And Results names the software that made it.

19.1.8 Export The Board With KESE

The rest of this page is what happens between python simulation.py and the numbers in the results files, step by step. Every step is one function of the bridge on the Elmer_Integration branch; the file is named with each.

bridge/geometry.py runs KESE as a program, never as a library:

python run_KESE.py board.kicad_pcb --for elmer --format step stl --out <folder> \
    --set Stackup.solder_mask=True ...

The elmer preset writes simulation-mode solids, one per net and one per dielectric, in mm on KiCad's origin, with no surface finish (Choosing An Export). The bridge asks for STL beside STEP and reads the STL files with trimesh, together with materials.json for each part's role, net, layer and height. By default it asks for a 20 µm solder mask over copper and laminate with tented vias, as the coil boards' brief does.

bridge/study.py keeps the export in one of two places. kese_export keeps it in a scratch cache named by a hash of the board file (E01 and E02). kese_geometry keeps it in a folder meant to be committed beside the board, with a source.json holding that hash (the coil board's 3D_Geometry/). Either way an unchanged board is not exported twice.

KESE writes the board with y up (y_model = −y_KiCad) and z = 0 in the middle of the board. The bridge shifts z so that the top face of the F.Cu copper is z = 0.

19.1.9 Section The Parts Into Slabs

bridge/mesh25d.py builds a 2.5D mesh, the shape a printed board has: everything is flat in z. Layout.build takes every height at which some part starts or ends, which splits the board into slabs, and cuts each part at the middle of each slab it spans, giving one 2D outline per part and slab.

For the magneto-quasi-static solve an insulator with μr = 1 is air: the A-V solver has no displacement current, so εr plays no part. insulators=False therefore leaves out FR-4 and mask altogether, which removes their heights from the slabs; with insulators=True they are kept, and a board or mask part that lies wholly outside the copper's heights is merged into the air anyway. All three boards on the Elmer FEM pages run with insulators=False.

19.1.10 Triangulate The Footprint

One triangle mesh covers the whole footprint: a disc around the board (its rim sized to the far field's element size), with every copper edge of every slab drawn into it as a line, so each triangle lies wholly inside or outside the copper in every slab. The element size comes from a raster: h_edge at copper edges, growing by grade per mm away from them, at most h_in inside copper and h_max far away. Lines given in extra_lines (port sheets, the outline of a cut, a rotor's copper at its angle) are drawn in too.

19.1.11 Stack The Wedges, Fill The Air

The triangle mesh is repeated at a series of heights in z and joined into wedges (prisms):

Slab Layer height
A copper foil (a slab with copper, at most foil_max = 0.15 mm thick) at most dz_copper (E01 and E02 use 0.018 mm at level 1, about half copper's skin depth at 3.5 MHz)
Any other slab, including a dielectric that holds only via barrels, and the air gap to a rotor at most dz_max
Above and below the boards two thin air layers (pads), then tetrahedra

Above and below the wedges, gmsh fills the air with tetrahedra out to the top and bottom of the domain, growing from the wedges' size by tet_grade per mm up to tet_max, then optimises them with Netgen. Each wedge gets the body of the part of highest priority whose outline holds its triangle (copper over mask over board); a void part (air of higher priority than copper) takes copper out, which is how a cut across a trace or a left-out via is made in the model while the board file stays as it is.

19.1.12 Open Each Coil At Its Port

Elmer's 3D massive coils take their current's direction from a potential (W) that runs from 0 at one electrode to 1 at the other, so a coil must be open. bridge/ports.py opens it where the real board gets its leads:

Port part What it is Boundary condition
Electrodes T1 and T2 the coil's copper faces that border the gap (two separate groups) W = 0 (T1), W = 1 (T2), and the scalar potential fixed (A re = A im = 0)
Sheet faces inside the gap that join the two electrodes n × A = 0 (A re {e} = 0, A im {e} = 0)

The gap is wherever the coil's copper is absent:

Coil Opened at Sheet
E01's loop, E02's TX and RX the 0.2 mm gap between the trace's two round ends across the gap at a level of the copper (sheet_at_level)
The coil board's TX its two ends, stacked on F.Cu and B.Cu at one point upright through the board between them (sheet_vertical, along a line drawn into the mesh)
The coil board's SIN and COS a 0.2 mm cut across a top trace, 0.4 mm across, made in the model across the cut's floor, at the copper's lower face, as on E01

With the sheet in place, the coil's voltage is IR + jω∮A·dl round the whole loop, gap included: the coil's EMF, as a meter at its leads would read it.

How the coil board sits in Elmer, drawn from the geometry the mesh is built from. Left, seen from above: the stator's TX in dark grey (three turns on F.Cu), SIN in blue and COS in orange, each on F.Cu and B.Cu, with the rotor's two quarter-ring copper sectors in grey at 0 degrees, 1 mm above and copper face down; SIN's and COS's ports are ringed where a 0.2 mm cut crosses a top trace, and the TX port at its two stacked ends at KiCad (111, 100). Top right, a section through the stack with heights stretched: the rotor copper 1 mm above the stator, FR-4 and mask treated as air, and air out to 35.1 mm from the axis and 35.1 mm above and below. Bottom right: the SIN port, the cut's two faces as electrodes and a dashed port sheet across the gap's floor, with 0 A forced through SIN so the voltage across the cut is its open-circuit EMF; and the TX port, an electrode on each stacked end and a hatched port sheet between them, where 1 A is driven at 3.5 MHz

The coil board's three ports, drawn by its rig_picture.py.

The coil board's cuts are made in the model; the board files stay as the generator wrote them. Each is the spot on the receiver's top trace nearest its layer-change via where a 0.2 mm cut has at least 0.45 mm of free board round it and sits at least 0.75 mm from any via centre: 0.86 mm from the via on both receivers, at KiCad (96.591, 100.496) for SIN and (97.239, 97.940) for COS. The two spots are 45° apart about the axis, a quarter of the electrical period, as SIN and COS are.

Where SIN and COS are opened. Left, the stator from above with the TX in dark grey, SIN in blue and COS in orange, each on F.Cu (dark) and B.Cu (light); a small white box marks each cut and the TX port is ringed at the right. Right, close-ups: SIN cut at KiCad (96.59, 100.50) and COS cut at KiCad (97.24, 97.94), each a 0.2 mm white box across the top trace 0.86 mm from the via, which stays, with 0.46 mm clear of other copper; and the TX's two ends, F.Cu over B.Cu, at KiCad (111.00, 100.00), not cut. A note says the copper inside each box is taken out, the two cut faces become the electrodes and the port sheet spans the gap at the trace's lower face

19.1.13 Write The Elmer Case

bridge/elmer_case.py writes one .sif per frequency:

Solver What it does
1 WPotentialSolver W in each coil, once, before everything, with a direct solve (UMFPACK)
2 CircuitsAndDynamicsHarmonic one circuit per coil: a current source of 1 A for the driven coil and 0 A for a sensing coil
3 WhitneyAVHarmonicSolver A (edge elements) and V in the conductors, complex, with the circuits; iterative or direct, below
4 MagnetoDynamicsCalcFields current density, field energy and eddy power
5 CircuitsOutput every circuit's V and I
6 SaveScalars the scalars to res_<name>/scalars_<name>.dat

The A-V solve has two modes (Case.solver):

Mode What Elmer is told Used by
iterative (the default) BiCGStab(l) of degree 4 or GCR, with Elmer's Circuit preconditioner, optionally with an ILU of the field's block (ilu_order, shifted by ilu_factor); the run goes on at the iteration cap (Linear System Abort Not Converged = False) E01 and E02 (BiCGStab(l), no ILU)
mumps a direct solve with serial MUMPS (mumpslocal), Use Tree Gauge = False and Mumps Solve Singular = True, so A stays ungauged and MUMPS handles the null pivots of the gradients the coil board

Every coil is a massive component (Coil Type = Massive). Conductors that are not coils (a rotor) are ordinary conducting bodies, with their own scalar potential fixed to 0 by default (conductor_potential=False), so there E = −jωA. The outer boundary has n × A = 0. Coordinates stay in mm (Coordinate Scaling = 0.001).

Note

Activate Constraint on the massive coils is off by default today (constraint=False), and the eddy power is then a second check on R. E01 and E02 ran on 15 and 16 November with it on, the bridge's setting then; the coil board ran on 17 November with it off.

19.1.14 Solve And Read Back

bridge/study.py runs ElmerSolver once per frequency (OpenMP threads set by threads, the stack limit lifted for serial MUMPS), reads the scalars and, for an iterative solve, the last iteration count and residual from its log, and records Elmer's peak memory. Per coil it reports:

Result From
V, I, Z = V / I the circuit outputs
R = Re Z, L = Im Z / ω Z
M, the mutual inductance to the driven coil Im(V_sense / I_drive) / ω, for a coil with no current
R_dc Elmer's r_component, from ∫σ|∇W|²
L from the field energy 2W / I², a check on L that does not go through the circuit
R from the eddy power 2P / I², a check on R (right only with Activate Constraint off)

All of it, with the mesh's size, the run's time, memory and the software versions, is written to the example's results files; each example's results page sets it against the reference.

19.1.15 A Rotor Over A Stator

The coil board adds a second board. load_parts turns the rotor copper side down without mirroring it, lifts its copper face to the air gap above z = 0, and turns it about the axis (KiCad's point (100, 100)) by the rotor angle. Every angle gets its own mesh, with the rotor's copper at that angle drawn into it, and one solve; a run with the rotor's copper made air gives the TX with the rotor away. The receivers' M at each angle is fitted with a sine, and the angle read back as atan2(SIN, COS) gives the angle error (Elmer FEM Test Boards And Results).

Previous Next
Walkthrough PyPEEC Walkthrough