Repository navigation
PyPEEC Test Boards And Results
Three boards: the proof boards E01 and E02 in Examples/, whose answers are known without any solver,
and the inductive encoder board S0d2_1x_OD23_2L_tiny_TX3top_Cut in Examples/Inductive Coils/, all on
the PyPEEC_Integration branch. Every number here is in their results files, with the settings, the
versions, the grid, the time, the memory and PyPEEC's own checks of every solve. The branch solves five
more coil boards in the same way, listed in
Examples/Inductive Coils/README.md.
One circular trace on F.Cu, 10 mm in radius to its centre line, 0.5 mm wide and 35 µm thick, opened by a 0.2 mm gap where the bridge puts its two terminals, on a 30 mm square board; PyPEEC drives 1 A through it.
| Top | Bottom |
|---|---|
![]() |
![]() |
| Quantity | Reference | 100 µm | 50 µm | 25 µm | 12.5 µm |
|---|---|---|---|---|---|
| Grid (one voxel layer, 35 µm) | 208 × 208 | 412 × 412 | 822 × 822 | 1642 × 1642 | |
| Copper voxels | 3,102 | 12,467 | 49,979 | 199,997 | |
| L at 10 kHz | 55.99 to 56.44 nH | 57.00 nH (+1.8 %) | 56.59 nH (+1.1 %) | 56.24 nH (+0.44 %) | 56.09 nH (+0.18 %) |
| L from the stored energy at 10 kHz | the same | 57.00 nH | 56.59 nH | 56.24 nH | 56.09 nH |
| R at 10 kHz | 61.20 mΩ | 69.25 mΩ (+13 %) | 65.23 mΩ (+6.6 %) | 63.20 mΩ (+3.3 %) | 62.30 mΩ (+1.8 %) |
| R from the losses at 10 kHz | the same | 69.25 mΩ | 65.23 mΩ | 63.20 mΩ | 62.30 mΩ |
| L at 3.5 MHz | about 55.44 nH (an estimate) | 56.14 nH | 55.61 nH | 55.16 nH | 54.99 nH (−0.8 %) |
| R at 3.5 MHz | 83.37 mΩ | 81.93 mΩ | 80.53 mΩ | 79.79 mΩ | |
| R at 3.5 MHz over R at 10 kHz | 1.20 | 1.26 | 1.27 | 1.28 |
L settles from above into the band that Grover's ring formula gives the open loop (55.99 nH with the current stopped at the round ends' centres, 56.44 nH with it taken on to the gap's faces), each step about half the one before, which puts its limit at about 55.9 to 56.0 nH, the band's lower end. R's excess over the annular sector's DC resistance halves with each halving of the voxels, since the trace's round edges are drawn as steps, and taken to zero voxel size it is 61.4 mΩ, 0.3 % over the sector, which the two half-discs past the sector's ends add. L and R from the terminals' voltage and from the stored energy and the losses agree to the last digit at every size, so the terminals and the read-back measure what the field holds. At 3.5 MHz R rises by 28 % as the current crowds to the trace's edges, and every solve took one GMRES iteration and passed PyPEEC's own checks.
E01's loop twice on the same 30 mm board, TX on F.Cu and RX on B.Cu directly under it, 1.565 mm apart; TX carries 1 A and RX is open (0 A), so the voltage across RX's gap gives the mutual inductance M.
| Top | Bottom |
|---|---|
![]() |
![]() |
| Quantity | Reference | 100 µm | 50 µm |
|---|---|---|---|
| Grid | 208 × 208 × 46 | 412 × 412 × 46 | |
| M at 10 kHz | 24.13 nH | 24.01 nH (−0.51 %) | 24.09 nH (−0.17 %) |
| M at 3.5 MHz | about 24.13 nH | 23.78 nH | 23.84 nH |
| TX's L at 10 kHz | E01's: 57.00 and 56.59 nH | 57.00 nH | 56.60 nH (+0.01 %) |
| TX's L from the stored energy at 10 kHz | the same | 57.00 nH | 56.60 nH |
| TX's R at 10 kHz | E01's: 69.25 and 65.23 mΩ | 69.25 mΩ | 65.23 mΩ |
| TX's L at 3.5 MHz | E01's: 56.14 and 55.61 nH | 56.09 nH (−0.08 %) | 55.55 nH (−0.09 %) |
| TX's R at 3.5 MHz | E01's: 83.37 and 81.93 mΩ | 83.88 mΩ (+0.6 %) | 82.56 mΩ (+0.8 %) |
M is 0.17 % under Maxwell's formula for two coaxial loops at 50 µm, and its error fell from 0.51 % when the voxels halved, so its limit is at or a little over 24.13 nH; the reference carries the same 0.8 % open-loop uncertainty as E01's L, so the board cannot tell the two apart more finely than that. The open RX leaves the TX's L and R as E01's to 0.01 % at 10 kHz, as a loop with no current round it must. At 3.5 MHz the RX's eddy currents, circulating across its trace, add 0.8 % to the TX's R and show as a real part of the mutual impedance, 3.2 mΩ at 50 µm: the proximity effect.
An inductive angle encoder from the
Sinusoidal Coil Generator,
23.4 mm across: a stator with a three-turn TX on the top layer round two receivers, SIN and COS, each
making two sine periods per turn, under a rotor of two quarter-ring copper sectors, solved at 16 angles
over the whole turn at each of five air gaps with 1 A at 3.5 MHz in the TX (non-commercial licence, see
Examples/Inductive Coils/LICENSE.md).

| Air gap | Amplitude SIN / COS | Angle error (electrical) | Solves passing both checks | L TX over the turn |
|---|---|---|---|---|
| 2 mm | 1.89 / 1.90 nH (42 / 42 mV) | 0.2° rms, 0.3° peak | 16 of 16 | 284.1 to 284.3 nH |
| 1.5 mm | 2.94 / 2.95 nH (65 / 65 mV) | 0.2° rms, 0.4° peak | 16 of 16 | 280.1 to 280.4 nH |
| 1 mm | 4.61 / 4.63 nH (101 / 102 mV) | 0.2° rms, 0.4° peak | 16 of 16 | 271.5 to 272.0 nH |
| 0.5 mm | 7.14 / 7.16 nH (157 / 157 mV) | 0.4° rms, 0.7° peak | 16 of 16 | 257.1 to 257.7 nH |
| 0.1 mm | 9.60 / 9.62 nH (211 / 212 mV) | 0.9° rms, 1.3° peak | 16 of 16 | 235.7 to 236.6 nH |
| rotor away | 1 of 1 | 296.4 nH |


All 81 solves pass both checks, the TX's L and R from its voltage agreeing with the stored energy and
the losses within 0.001 %, and at every gap SIN and COS are within 0.4 % of each other in amplitude and
89.9° to 90.1° apart. The signal grows 5.1 times from 2 mm to 0.1 mm, and the angle error is 0.2° rms
from 1 to 2 mm, 0.4° at 0.5 mm and 0.9° at 0.1 mm in electrical degrees (half that in mechanical
degrees), where it alternates in sign from one angle to the next: the fourth-harmonic ripple that
two-coil sensors typically show (Kuntz, Gerlach and Fella, arXiv 2503.14627).
The second half turn repeats the first to the last digit, because the rotor's two sectors, turned by
180°, fall on the very same voxels. The rotor lowers L TX from 296.4 nH by 8.3 % at 1 mm and by 20 % at
0.1 mm, where the generator estimated 292 nH with the rotor away and 226 nH with it, an upper estimate
of the drop. Every solve, with its M, L, R, iterations, residual, memory and time, is in the board's
Results/SINCOS_Results.md.
| Previous | Next |
|---|---|
| Elmer FEM Test Boards And Results | FastHenry Test Boards And Results |
Code and documentation: GNU GPL v3 or later, including material derived from KiCad · Font data: KiCad newstroke notices (see License) · Repository
Start Here
Working Principle
Features
Tests
FEM Solvers' Integration
References And Compatibilities
- Parameter Reference
- Checks, Errors And Warnings
- Material Properties
- KiCad And Solver Compatibility
- openEMS Workflow
Research And Community