Skip to content

PyPEEC Test Boards And Results

github-actions[bot] edited this page Nov 19, 2026 · 1 revision

21.2 PyPEEC Test Boards And Results

Three boards: the proof boards E01 and E02 in Examples/, whose answers are known without any solver, and the inductive encoder board S0d2_1x_OD23_2L_tiny_TX3top_Cut in Examples/Inductive Coils/, all on the PyPEEC_Integration branch. Every number here is in their results files, with the settings, the versions, the grid, the time, the memory and PyPEEC's own checks of every solve. The branch solves five more coil boards in the same way, listed in Examples/Inductive Coils/README.md.

21.2.1 E01 Circular Loop

One circular trace on F.Cu, 10 mm in radius to its centre line, 0.5 mm wide and 35 µm thick, opened by a 0.2 mm gap where the bridge puts its two terminals, on a 30 mm square board; PyPEEC drives 1 A through it.

Top Bottom
E01 from the top, rendered by KESE: a 30 mm square board with one yellow copper loop, 10 mm in radius and 0.5 mm wide, opened on the right by a small gap between its two round ends E01 from the bottom, rendered by KESE: the bare board, since B.Cu holds no copper
Quantity Reference 100 µm 50 µm 25 µm 12.5 µm
Grid (one voxel layer, 35 µm) 208 × 208 412 × 412 822 × 822 1642 × 1642
Copper voxels 3,102 12,467 49,979 199,997
L at 10 kHz 55.99 to 56.44 nH 57.00 nH (+1.8 %) 56.59 nH (+1.1 %) 56.24 nH (+0.44 %) 56.09 nH (+0.18 %)
L from the stored energy at 10 kHz the same 57.00 nH 56.59 nH 56.24 nH 56.09 nH
R at 10 kHz 61.20 mΩ 69.25 mΩ (+13 %) 65.23 mΩ (+6.6 %) 63.20 mΩ (+3.3 %) 62.30 mΩ (+1.8 %)
R from the losses at 10 kHz the same 69.25 mΩ 65.23 mΩ 63.20 mΩ 62.30 mΩ
L at 3.5 MHz about 55.44 nH (an estimate) 56.14 nH 55.61 nH 55.16 nH 54.99 nH (−0.8 %)
R at 3.5 MHz 83.37 mΩ 81.93 mΩ 80.53 mΩ 79.79 mΩ
R at 3.5 MHz over R at 10 kHz 1.20 1.26 1.27 1.28

L settles from above into the band that Grover's ring formula gives the open loop (55.99 nH with the current stopped at the round ends' centres, 56.44 nH with it taken on to the gap's faces), each step about half the one before, which puts its limit at about 55.9 to 56.0 nH, the band's lower end. R's excess over the annular sector's DC resistance halves with each halving of the voxels, since the trace's round edges are drawn as steps, and taken to zero voxel size it is 61.4 mΩ, 0.3 % over the sector, which the two half-discs past the sector's ends add. L and R from the terminals' voltage and from the stored energy and the losses agree to the last digit at every size, so the terminals and the read-back measure what the field holds. At 3.5 MHz R rises by 28 % as the current crowds to the trace's edges, and every solve took one GMRES iteration and passed PyPEEC's own checks.

21.2.2 E02 Coaxial Loops

E01's loop twice on the same 30 mm board, TX on F.Cu and RX on B.Cu directly under it, 1.565 mm apart; TX carries 1 A and RX is open (0 A), so the voltage across RX's gap gives the mutual inductance M.

Top Bottom
E02 from the top, rendered by KESE: the TX loop on F.Cu, opened on the right E02 from the bottom, rendered by KESE: the RX loop on B.Cu right under the TX, its gap showing on the left as the board is seen from below
Quantity Reference 100 µm 50 µm
Grid 208 × 208 × 46 412 × 412 × 46
M at 10 kHz 24.13 nH 24.01 nH (−0.51 %) 24.09 nH (−0.17 %)
M at 3.5 MHz about 24.13 nH 23.78 nH 23.84 nH
TX's L at 10 kHz E01's: 57.00 and 56.59 nH 57.00 nH 56.60 nH (+0.01 %)
TX's L from the stored energy at 10 kHz the same 57.00 nH 56.60 nH
TX's R at 10 kHz E01's: 69.25 and 65.23 mΩ 69.25 mΩ 65.23 mΩ
TX's L at 3.5 MHz E01's: 56.14 and 55.61 nH 56.09 nH (−0.08 %) 55.55 nH (−0.09 %)
TX's R at 3.5 MHz E01's: 83.37 and 81.93 mΩ 83.88 mΩ (+0.6 %) 82.56 mΩ (+0.8 %)

M is 0.17 % under Maxwell's formula for two coaxial loops at 50 µm, and its error fell from 0.51 % when the voxels halved, so its limit is at or a little over 24.13 nH; the reference carries the same 0.8 % open-loop uncertainty as E01's L, so the board cannot tell the two apart more finely than that. The open RX leaves the TX's L and R as E01's to 0.01 % at 10 kHz, as a loop with no current round it must. At 3.5 MHz the RX's eddy currents, circulating across its trace, add 0.8 % to the TX's R and show as a real part of the mutual impedance, 3.2 mΩ at 50 µm: the proximity effect.

21.2.3 S0d2_1x_OD23_2L_tiny_TX3top_Cut

An inductive angle encoder from the Sinusoidal Coil Generator, 23.4 mm across: a stator with a three-turn TX on the top layer round two receivers, SIN and COS, each making two sine periods per turn, under a rotor of two quarter-ring copper sectors, solved at 16 angles over the whole turn at each of five air gaps with 1 A at 3.5 MHz in the TX (non-commercial licence, see Examples/Inductive Coils/LICENSE.md).

S0d2_1x_OD23_2L_tiny_TX3top_Cut drawn by the coil generator: the stator on the left, a round board 2 to 11.7 mm in radius, with three red TX turns on the top layer round the outside and the SIN and COS receivers inside them, red on Top and blue on Bottom with vias as dots, each making two sine periods per turn; the rotor on the right with two red quarter-ring copper sectors opposite each other

Air gap Amplitude SIN / COS Angle error (electrical) Solves passing both checks L TX over the turn
2 mm 1.89 / 1.90 nH (42 / 42 mV) 0.2° rms, 0.3° peak 16 of 16 284.1 to 284.3 nH
1.5 mm 2.94 / 2.95 nH (65 / 65 mV) 0.2° rms, 0.4° peak 16 of 16 280.1 to 280.4 nH
1 mm 4.61 / 4.63 nH (101 / 102 mV) 0.2° rms, 0.4° peak 16 of 16 271.5 to 272.0 nH
0.5 mm 7.14 / 7.16 nH (157 / 157 mV) 0.4° rms, 0.7° peak 16 of 16 257.1 to 257.7 nH
0.1 mm 9.60 / 9.62 nH (211 / 212 mV) 0.9° rms, 1.3° peak 16 of 16 235.7 to 236.6 nH
rotor away 1 of 1 296.4 nH

SIN and COS of S0d2_1x_OD23_2L_tiny_TX3top_Cut against the rotor angle at a 1 mm air gap, 0 to 360°: the mutual inductance from the TX in nH, SIN in blue and COS in orange, one dot per PyPEEC solve joined by solid lines, each swinging about ±4.6 nH twice per turn, COS leading SIN by a quarter of the 180° period; the dotted ideal sine and cosine, each channel's best fit, lie almost on the solves

SIN of S0d2_1x_OD23_2L_tiny_TX3top_Cut at each air gap against the rotor angle, 0 to 360°: five curves, one per gap, from ±9.6 nH at 0.1 mm (red) through 0.5, 1 and 1.5 mm to ±1.9 nH at 2 mm (teal), each with its dotted best sine; below, each solve less its ideal curve, within ±0.02 nH at 2 mm and up to about ±0.2 nH at 0.1 mm, alternating in sign from one angle to the next

All 81 solves pass both checks, the TX's L and R from its voltage agreeing with the stored energy and the losses within 0.001 %, and at every gap SIN and COS are within 0.4 % of each other in amplitude and 89.9° to 90.1° apart. The signal grows 5.1 times from 2 mm to 0.1 mm, and the angle error is 0.2° rms from 1 to 2 mm, 0.4° at 0.5 mm and 0.9° at 0.1 mm in electrical degrees (half that in mechanical degrees), where it alternates in sign from one angle to the next: the fourth-harmonic ripple that two-coil sensors typically show (Kuntz, Gerlach and Fella, arXiv 2503.14627). The second half turn repeats the first to the last digit, because the rotor's two sectors, turned by 180°, fall on the very same voxels. The rotor lowers L TX from 296.4 nH by 8.3 % at 1 mm and by 20 % at 0.1 mm, where the generator estimated 292 nH with the rotor away and 226 nH with it, an upper estimate of the drop. Every solve, with its M, L, R, iterations, residual, memory and time, is in the board's Results/SINCOS_Results.md.

Previous Next
Elmer FEM Test Boards And Results FastHenry Test Boards And Results